No backup time (Temps de sauvegarde absent) #79

Open Ririx02 opened 3 years ago

Ririx02 commented 3 years ago

Bonjour, Je viens de remarqué un petit bug depuis la dernière mise à jour, il n'y a plus le temps restant : Sans titre Hello, I just noticed a small bug since the last update, there is no more time left

Ririx02 commented 3 years ago

Variable list => ups (American Power Conversion/Back-UPS RS 1500G/878.L4 .I) battery.charge (Description unavailable) : 100 battery.charge.low (Description unavailable) : 10 battery.charge.warning (Description unavailable) : 50 battery.date (Description unavailable) : 2001/09/25 battery.mfr.date (Description unavailable) : 2017/01/19 ===========================> battery.runtime (Description unavailable) : 3552 battery.runtime.low (Description unavailable) : 120 battery.type (Description unavailable) : PbAc battery.voltage (Description unavailable) : 27.0 battery.voltage.nominal (Description unavailable) : 24.0 device.mfr (Description unavailable) : American Power Conversion device.model (Description unavailable) : Back-UPS RS 1500G device.serial (Description unavailable) : 3B1628X19186 device.type (Description unavailable) : ups driver.name (Description unavailable) : usbhid-ups driver.parameter.pollfreq (Description unavailable) : 30 driver.parameter.pollinterval (Description unavailable) : 5 driver.parameter.port (Description unavailable) : auto driver.version (Description unavailable) : DSM6-2-25510-201118 driver.version.data (Description unavailable) : APC HID 0.95 driver.version.internal (Description unavailable) : 0.38 input.sensitivity (Description unavailable) : medium input.transfer.high (Description unavailable) : 288 input.transfer.low (Description unavailable) : 176 input.transfer.reason (Description unavailable) : input voltage out of range input.voltage (Description unavailable) : 230.0 input.voltage.nominal (Description unavailable) : 230 ups.beeper.status (Description unavailable) : disabled ups.delay.shutdown (Description unavailable) : 20 ups.firmware (Description unavailable) : 878.L4 .I ups.firmware.aux (Description unavailable) : L4 ups.load (Description unavailable) : 42 ups.mfr (Description unavailable) : American Power Conversion ups.mfr.date (Description unavailable) : 2016/07/15 ups.model (Description unavailable) : Back-UPS RS 1500G ups.productid (Description unavailable) : 0002 ups.realpower.nominal (Description unavailable) : 865 ups.serial (Description unavailable) : 3B1628X19186 ups.status (Description unavailable) : OL ups.test.result (Description unavailable) : No test initiated ups.timer.reboot (Description unavailable) : 0 ups.timer.shutdown (Description unavailable) : -1 ups.vendorid (Description unavailable) : 051d

FileCity commented 3 years ago

J'ai aussi remarqué ce comportement avec la Pre-release 2.1,

Ririx02 commented 3 years ago

Je suis aussi en V2.1.7740.35837

FileCity commented 3 years ago

J'utilise la version 2.0 sur les machines critiques pour cette raison. Je test la 2.1 mais ne l'utilise pas en production.

gawindx commented 3 years ago

Je rebondis tardivement, j’avais déjà remarqué ce bug dans la version 2.1, mais pas vu pour la 2.0.

Des lignes de codes commentés et je ne les ai pas vu, donc elles étaient restés commentées...

Ririx02 commented 3 years ago

Si c'est juste à dé-commenter, ça ira vite à rectifier, courage à toi (enfin vous, l'équipe de dev, si j'ai bien suivi l'histoire) de nous fournir ce soft 👍

gawindx commented 3 years ago

Merci L’équipe et moi même te remercions, c’est à dire moi et... moi (et quelques contributeurs quand même)