gawindx / WinNUT-Client

This is a NUT windows client for monitoring your ups hooked up to your favorite linux server.
GNU General Public License v3.0
395 stars 70 forks source link

How to fill out the calibration screen #90

Open dstewen opened 3 years ago

dstewen commented 3 years ago

Firstly I wanted to say thanks for putting together this software.

After a bit of trial and error I have got to talking to the nut-server running on my raspberry pi3b.

OK. So from reading the issues it appears that the calibration tab under options is for calibrating the gauges to closer represent my ups.

What settings should I be using based on this upsc output?

pi@pi3b:~ $ upsc ups@localhost Init SSL without certificate database battery.charge: 100 battery.charge.low: 10 battery.charge.warning: 50 battery.runtime: 3238 battery.runtime.low: 150 battery.type: PbAc battery.voltage: 26.4 battery.voltage.nominal: 24.0 device.mfr: American Power Conversion device.model: Smart-UPS_1500 device.serial: ASXXXXXXXXXX device.type: ups driver.flag.pollonly: enabled driver.name: usbhid-ups driver.parameter.pollfreq: 30 driver.parameter.pollinterval: 10 driver.parameter.port: auto driver.parameter.synchronous: no driver.parameter.vendorid: 051d driver.version: 2.7.4 driver.version.data: APC HID 0.96 driver.version.internal: 0.41 ups.beeper.status: enabled ups.delay.shutdown: 20 ups.firmware: UPS 04.1 / ID=1018 ups.mfr: American Power Conversion ups.mfr.date: 2020/11/11 ups.model: Smart-UPS_1500 ups.productid: 0003 ups.serial: ASXXXXXXXXXX ups.status: OL ups.timer.reboot: -1 ups.timer.shutdown: -1 ups.vendorid: 051d