Open M0LTE opened 2 years ago
There seems to be quite a few issues around ozone and circulation pump. On my current tub I have a waterfall that is also the circulation pump (and the o3 pump too). I can turn this on or off from the integration or the app when the spa is idle, but if any other pump is active then the circulation pump comes on automatically and can't be turned off no matter what. This is true of the integration, the iOS app and the spa control panel.
I think I need to do some more thinking around these items, but thanks for giving me the data. Can you also let me know the model of spapack and the version numbers too so I can see what the underlying configuration is set to?
Sure, where do I find that info please?
I also see the same behaviour- that's expected and normal- we like to have just the O3 pump on by itself a lot of the time.
Thanks.
Settings > Device & Services > Integrations Click on the Gecko integration and select the device On the device page, you should see Device Info
mine shows
inXM 186 v3.0
by Gecko Alliance
Firmware: SpaPack:v33.00 Config:9 Log:9
Hardware: EN:88 v15.0 CO:89 v11.0
Hi, great integration, thanks. Unable to control my ozone pump - blower and jets are just fine. This maps to the 'bubbles' button in the in.touch 2 app. There is just no switch entity for it, just a binary_sensor. Any ideas please?