gdwaterworth / Home-Assistant---E-Linter-Logger---Sunsynk

32 stars 9 forks source link

Request for Data // Some information #12

Closed dj-louw closed 8 months ago

dj-louw commented 1 year ago

Hi,

On your wiki you have requested some data from users. I can provide you with some of this.

I have a geyser/hot water cylinder connected to my Aux port of the inverter, which is set to come on only if the battery is fully charged and if there is sufficient solar to do so.

At this time, I do not have anything connected as non-essential loads on the grid side of the inverter.

As an aside, I don't think the inverter can actually report on the Aux port load. I am not seeing that value on the app anywhere, and neither am I seeing it in any of the below datasets. On the inverter screen itself, it reports Aux separately, but then it includes the aux load when showing the UPS load as well. My geyser is 2kW, the home draws 500W. So Aux port reads 2kW, UPS port reads 2.5kW.

You have requested info about the following. See my provided data below.

sensor.sunsynk_load

totalUsed: 73.9
dailyUsed: 5.2
vip_0_volt: '243.3'
vip_0_current: '0.0'
vip_0_power: 4833
totalPower: 4833
smartLoadStatus: 1
loadFac: 49.96
upsPowerL1: 0
upsPowerL2: 0
upsPowerL3: 0
upsPowerTotal: 0
total: 73.9
volt: '243.3'
power: 4833
totalpower: 4833
calc_current: '19.86'

sensor.sunsynk_input

pac: 4703
pvIV_0_id: Missing
pvIV_0_pvNo: 1
pvIV_0_vpv: '388.7'
pvIV_0_ipv: '12.3'
pvIV_0_ppv: '4703.0'
pvIV_0_todayPv: '0.0'
pvIV_0_sn: '2209244812'
pvIV_0_time: '2023-04-11 10:24:56'
pvIV_1_id: Missing
pvIV_1_pvNo: 2
pvIV_1_vpv: '2.5'
pvIV_1_ipv: '0.0'
pvIV_1_ppv: '0.0'
pvIV_1_todayPv: '0.0'
pvIV_1_sn: '2209244812'
pvIV_1_time: '2023-04-11 10:24:56'
mpptIV: Missing
etoday: 9.3
etotal: 84.8
pv: 4703
pv1: 4703
pv1_volt: 388.7
pv1_current: 12.3
pv2: 0
pv2_volt: 2.5
pv2_current: 0
pvtotal: 84.8

sensor.sunsynk_grid

vip_0_volt: '243.1'
vip_0_current: '2.6'
vip_0_power: 0
pac: 0
qac: 0
fac: 50.06
pf: 1
status: 0
etodayFrom: '2.7'
etodayTo: '0.0'
etotalFrom: '10.5'
etotalTo: '0.0'
limiterTotalPower: -40
total: 10.5
volt: '243.1'
current: '2.6'
gridonline: true
power: 0

sensor.sunsynk_output

vip_0_volt: '241.3'
vip_0_current: '19.4'
vip_0_power: 4833
pInv: 4703
pac: 4833
fac: 50

sensor.sunsynk_flow

custCode: 29
meterCode: 0
pvPower: 4703
battPower: 408
gridOrMeterPower: 0
loadOrEpsPower: 4833
genPower: 0
minPower: 0
soc: 99
pvTo: true
toLoad: true
toGrid: false
toBat: false
batTo: true
gridTo: false
genTo: false
minTo: false
existsGen: false
existsMin: false
genOn: false
microOn: false
existsMeter: false
bmsCommFaultFlag: false
pv: Missing
existThinkPower: false
dj-louw commented 1 year ago

Additionally, I am registered on Region 2. So let me know if I can help with testing or information gathering.

gdwaterworth commented 1 year ago

Thanks

The api documentation I managed to get is really "crap". AUX/nonessential is really hard to find and pin down on how it is reported.

Wrt Region 2. I have a login, but my plant has not moved yet :/ I don't feel like manually moving the gateway as then I will lose my plant history. I will look at a flow export that should work on region 2. Will try upload it tonight

gdwaterworth commented 1 year ago

Additionally, I am registered on Region 2. So let me know if I can help with testing or information gathering.

I have added a version for Region 2 That should work