Hi, can you help me. I made a lot of changes, for my device work well. the device after install work during an time, more late the device is idle, sometimes it get back and work one moment. The end the device don't work.

esphome: name: $devicename friendly_name: $upper_devicename

esp8266: board: esp01_1m

external_components:

substitutions: devicename: p20240210-2 upper_devicename: Aire salon 2º #EJEMPLO

wifi: ssid: !secret wifi_ssid password: !secret wifi_password

Enable fallback hotspot (captive portal) in case wifi connection fails

ap: ssid: $upper_devicename password: !secret fallback_password2

captive_portal:

Enable logging

logger:

ESP8266 only - disable serial port logging, as the HeatPump component

needs the sole hardware UART on the ESP8266

level: VERBOSE

baud_rate: 0

Elimina 2 lineas de error que salen pero no resuelve el problema

logs:
component: ERROR

Enable Web server.

web_server: port: 80

Enable Home Assistant API

api:

ota:

Sync time with Home Assistant.

time:

climate:

Sensors with general information.

sensor:

Or you could use a HomeAssistant sensor

INFO ESPHome 2023.12.9 INFO Reading configuration /config/esphome/p20240210-2.yaml... INFO Detected timezone 'Europe/Madrid' INFO Starting log output from 192.168.1.156 using esphome API INFO Successfully connected to p20240210-2 @ 192.168.1.156 in 0.014s INFO Successful handshake with p20240210-2 @ 192.168.1.156 in 0.021s [17:31:34][I][app:102]: ESPHome version 2023.12.9 compiled on Feb 20 2024, 17:12:57

[17:31:34][C][wifi:405]: Local MAC: C8:C9:A3:3E:F9:6E [17:31:34][C][wifi:410]: SSID: [redacted] [17:31:34][C][wifi:411]: IP Address: 192.168.1.156 [17:31:34][C][wifi:412]: BSSID: [redacted]

[17:31:34][C][wifi:416]: Signal strength: -54 dB ▂▄▆█ [17:31:34][C][wifi:420]: Channel: 1 [17:31:34][C][wifi:421]: Subnet: 255.255.255.0 [17:31:34][C][wifi:422]: Gateway: 192.168.1.1 [17:31:34][C][wifi:423]: DNS1: 80.58.61.254 [17:31:34][C][wifi:424]: DNS2: 80.58.61.250

[17:31:34][C][logger:440]: Level: DEBUG [17:31:34][C][logger:441]: Log Baud Rate: 0 [17:31:34][C][logger:443]: Hardware UART: UART0 [17:31:34][C][logger:447]: Level for 'component': ERROR [17:31:34][C][homeassistant.time:010]: Home Assistant Time:

[17:31:34][I][MitsubishiHeatPump:062]: ESPHome MitsubishiHeatPump version 2.4.1 [17:31:34][I][MitsubishiHeatPump:504]: Supports HEAT: YES [17:31:34][I][MitsubishiHeatPump:505]: Supports COOL: YES [17:31:34][I][MitsubishiHeatPump:506]: Supports AWAY mode: NO [17:31:34][I][MitsubishiHeatPump:507]: Saved heat: 22.5 [17:31:34][I][MitsubishiHeatPump:508]: Saved cool: -1.0 [17:31:34][I][MitsubishiHeatPump:509]: Saved auto: -1.0 [17:31:34][C][captive_portal:088]: Captive Portal: [17:31:34][C][web_server:168]: Web Server: [17:31:34][C][web_server:169]: Address: p20240210-2.local:80

[17:31:34][C][mdns:116]: Hostname: p20240210-2 [17:31:34][C][ota:097]: Over-The-Air Updates: [17:31:34][C][ota:098]: Address: p20240210-2.local:8266 [17:31:34][W][ota:106]: Last Boot was an unhandled reset, will proceed to safe mode in 8 restarts [17:31:36][C][api:139]: API Server: [17:31:36][C][api:140]: Address: p20240210-2.local:6053 [17:31:36][C][api:144]: Using noise encryption: NO [17:31:36][C][homeassistant.sensor:030]: Homeassistant Sensor 'Temperatura Salon' [17:31:36][C][homeassistant.sensor:030]: State Class: '' [17:31:36][C][homeassistant.sensor:030]: Unit of Measurement: '' [17:31:36][C][homeassistant.sensor:030]: Accuracy Decimals: 1 [17:31:36][C][homeassistant.sensor:031]: Entity ID: 'sensor.temperature_salon' [17:31:38][D][api:102]: Accepted 192.168.1.145 [17:31:38][D][api.connection:1121]: Home Assistant 2024.2.1 (192.168.1.145): Connected successfully [17:31:38][D][time:044]: Synchronized time: 2024-02-20 17:31:38 [17:31:38][D][homeassistant.sensor:024]: 'sensor.temperature_salon': Got state 22.40 [17:31:38][D][sensor:093]: 'Temperatura Salon': Sending state 22.40000 with 1 decimals of accuracy [17:31:38][D][MitsubishiHeatPump:409]: Setting remote temp: 22.4 [17:31:42][D][climate:396]: 'Aire salon 2º' - Sending state: [17:31:42][D][climate:399]: Mode: HEAT [17:31:42][D][climate:401]: Action: IDLE [17:31:42][D][climate:404]: Fan Mode: AUTO [17:31:42][D][climate:416]: Swing Mode: OFF [17:31:42][D][climate:419]: Current Temperature: 22.50°C [17:31:42][D][climate:425]: Target Temperature: 22.50°C [17:31:49][D][climate:396]: 'Aire salon 2º' - Sending state: [17:31:49][D][climate:399]: Mode: HEAT [17:31:49][D][climate:401]: Action: HEATING [17:31:49][D][climate:404]: Fan Mode: AUTO [17:31:49][D][climate:416]: Swing Mode: OFF [17:31:49][D][climate:419]: Current Temperature: 22.50°C [17:31:49][D][climate:425]: Target Temperature: 22.50°C

those 3 lines repit sometimes WARNING p20240210-2 @ 192.168.1.156: Connection error occurred: [Errno 104] Connection reset by peer INFO Processing unexpected disconnect from ESPHome API for p20240210-2 @ 192.168.1.156 WARNING Disconnected from API

Bye

jesus51998 commented 4 months ago

I have 2 Mitsubishi, the MSZ-AP35VG, works very good with the same program, the MSZ-SF35VE2 doesn't work.

jesus51998 commented 3 months ago

My devices is working, change the software, and push software of "github://echavet/MitsubishiCN105ESPHome" and my MSZ-SF35VE2 work very good.

iannnnnnnn commented 3 months ago

Hi, I have a MFZ-KJ12NA and was having the same problem you are.

Setting the baud rate to 2400 solved the issue for me.

JaviElio commented 2 weeks ago

Same problem here. it works fine for some time, then stops and shows IDLE. Unplug/plug the external unit returns ESP's to live. Thanks for the info @iannnnnnnn, I'll try it