ghorwin / SIM-VICUS

Building and District Energy Simulation and more...
https://ghorwin.github.io/SIM-VICUS/
Other
33 stars 12 forks source link

Bug: LW Strahlungsmodell wird verwendet, obwohl nicht aktiviert #655

Closed ghorwin closed 1 year ago

ghorwin commented 1 year ago

Fehlermeldung beim Solverstart:

  Initializing Constructions and Interfaces
    Interface B of construction instance 'Internal wall between surfaces '#Ceiling (2)' and '#Floor (2)' (ID=120)' (#29) is an inside surface (connected to a zone), yet has solar radiation BC parameters defined. This is likely an error.
Interface #1 in construction instance #56 (Roof surface 1 (ID=37)) exchanges long wave radiation with interface #2 in construction instance #29 (Internal wall between surfaces '#Ceiling (2)' and '#Floor (2)' (ID=120)), but it has no long wave emission model defined.
Error initializing construction instance #29 'Internal wall between surfaces '#Ceiling (2)' and '#Floor (2)' (ID=120)'.
Critical error, simulation aborted.

Es wurde kein langwelliges Strahlungsmodell ausgewählt, daher sollte die Prüfung nicht durchgeführt werden.