Closed alebastianoni closed 2 months ago
Concentrations of TE need to be corrected by the sediment weight attacked with acid and microwave digested to report the actual concentration of the metal in ug of element/g of sediment and compare it with other values in the literature
This should be addressed by the user before adding the data to the env_dataset, in my opinion.
Added a comment in 6e56564c2edf96d63cc31b293c4e0cc8d2c63640
Concentrations of TE need to be corrected by the sediment weight attacked with acid and microwave digested to report the actual concentration of the metal in ug of element/g of sediment and compare it with other values in the literature