gmegan / specification

OpenSHMEM Application Programming Interface
http://www.openshmem.org
1 stars 0 forks source link

Atomicity Requirements for Two Different Teams #152

Open naveen-rn opened 4 years ago

naveen-rn commented 4 years ago

At present, two AMOs (same data type) from different contexts initiated by two different PEs targeting the same remote location should be atomic. Bring in Teams into this list, if the AMOs are initiated from two different teams - does the final remote update required to be atomic?