Open qbox4u opened 12 months ago
You should probably contact the company that you bought the hardware from.
I am using the default GRBL 1.1f build from here: https://github.com/gnea/grbl/releases/tag/v1.1f.20170801
Output is from UGS, so it is a bit more verbose - but as you can see it works fine:
>>> GXX
An error was detected while sending 'GXX': (error:2) Missing the expected G-code word value or numeric value format is not valid. Streaming has been paused.
>>> G545
An error was detected while sending 'G545': (error:20) Unsupported or invalid g-code command found in block. Streaming has been paused.
>>> G17
ok
>>> G18
ok
>>> G19
ok
>>> GXX
An error was detected while sending 'GXX': (error:2) Missing the expected G-code word value or numeric value format is not valid. Streaming has been paused.
Thanks Joacim
This confirms for me that the VEVOR 3018 Pro indeed should respond to G19 correctly and has an issue. ( i start to see more people with apparently the same issue when using fusion 360 )
You were a great help..
On Wed, Nov 29, 2023 at 10:13 AM Joacim Breiler @.***> wrote:
You should probably contact the company that you bought the hardware from.
I am using the default GRBL 1.1f build from here: https://github.com/gnea/grbl/releases/tag/v1.1f.20170801
Output is from UGS, so it is a bit more verbose - but as you can see it works fine:
GXX An error was detected while sending 'GXX': (error:2) Missing the expected G-code word value or numeric value format is not valid. Streaming has been paused. G545 An error was detected while sending 'G545': (error:20) Unsupported or invalid g-code command found in block. Streaming has been paused. G17 ok G18 ok G19 ok GXX An error was detected while sending 'GXX': (error:2) Missing the expected G-code word value or numeric value format is not valid. Streaming has been paused.
— Reply to this email directly, view it on GitHub https://github.com/gnea/grbl/issues/1236#issuecomment-1831502769, or unsubscribe https://github.com/notifications/unsubscribe-auth/AFMUGVINSDDUJ7QW6PCW5ELYG34CJAVCNFSM6AAAAAA77BD4TGVHI2DSMVQWIX3LMV43OSLTON2WKQ3PNVWWK3TUHMYTQMZRGUYDENZWHE . You are receiving this because you authored the thread.Message ID: @.***>
VEVOR confirmed that The supplier of the board did not implement and test the command G19 for the 3018PRO correctly VEVOR 3018 Pro Freezes after receiving G19 QUOTE OF VEVOR: Hello dear Thanks for your email.Sorry for inconvenience. our supplier never use it by that you said, so it's not mahcine problem and we also said operate by supplier s If there is any problem, pls contact us. Thanks for your understanding. Best regards Chris https://forums.autodesk.com/t5/forums/recentpostspage/post-type/message/user-id/14815108
The Manufacturer of the VEVOR 3018Pro is: Kunshan Boye Electronic Technology Co., Ltd. QUOTE OF VEVOR: if you want to contact with them, we're afraid that it is impossible, cause we asked them in a Wechat group any problem pls feel free to message us waiting for your reply Amber
i have the feeling that this is the right place to address a cnc issue for the Vevor 3018pro cpu firmware. please correct me if i am wrong.
the issue is quite simple See the video: https://www.youtube.com/shorts/mk0A7qj7N0s Fusion 360 generates a perfect output for cnc units, but als used G17, G18, G19 ** CNC part *** G1 Y15.762 X-28.762 Y-15.762 X27.762 Y-4.174 Y-3.856 G19 G3 Y-3.539 Z-4.682 J0 K0.318 G1 Z5 X21.922 Y-3.161 Z-4 Z-5 F150 G17 G2 X21.617 Y-3.625 I-2.146 J1.078 F500 G1 X21.614 Y-3.629
During execution of some samples, the cnc spindle was keep on running, but no serial communication was possible anymore. The programm was stuch on the line: G19 G3 Y-3.539 Z-4.682 J0 K0.318 The only way out was to reset the CPU board.
i will show the problem by means of the Candle console this shows the communication of the Vevor 3018 pro cnc https://www.youtube.com/shorts/QzzSysvoXXg
Grbl 1.1f ['$' for help] VIGOTEC.SDEM1.1.0.220328 GXX < error:2 G545 < error:20 G17 < ok G18 < ok G19 GXX CPU IS FROZEN
after reset, the console receives Grbl 1.1f ['$' for help] VIGOTEC.SDEM1.1.0.220328 This is correct
when the 3018Pro receives the false command "Gxx" it will reply "GXX < error:2" this is correct as error 2 means : “error:2” : _(“Numeric value format is not valid or missing an expected value.”), xx is not an numeric value, so this is the correct reply from the 3018
when a wrong G code would be send to the 3018 eg: G545 , the 3018pro replies: G545 < error:20 this would be correct as error 20 means: “error:20” : _(“Unsupported or invalid g-code command found in block.”),
when the 3018pro receives the command G17, it replies : G17 < ok this is correct
When the 3018 receives the command G19, the 3018 freezes and does not communicate anymore. this is an design flaw !!!
resuming the above it is proven that the 3018Pro CPU firmware has a design flaw as it does not return as expected if the code was not implemented with an error 20, but stops functioning !!!!!
i expect that the SW release of the 3018pro board is: Grbl 1.1f VIGOTEC.SDEM1.1.0.22032