issues
search
goecharger
/
go-eCharger-API-v1
API specification for V2 go-eCharger (compatible with V3 too)
100
stars
26
forks
source link
issues
Newest
Newest
Most commented
Recently updated
Oldest
Least commented
Least recently updated
Misc software issues
#68
povlhp
opened
3 years ago
1
How to switch between 1 and 3 phases
#67
povlhp
closed
3 years ago
2
Some findings about the api of the hardware version 3
#66
ddrrhh
closed
3 years ago
4
HTTP API V2 nicht äquivalent nutzbar wie V1
#65
chk2902
closed
3 years ago
1
<ip>/status -> couldn't take api lock in 3s, please try again later
#64
chk2902
closed
3 years ago
8
check if new firmware available
#63
clyso
closed
3 years ago
3
Update go-eCharger API v1 DE.md
#62
chilobo
closed
3 years ago
0
r1x
#61
chk2902
opened
3 years ago
0
KfW-Förderung: Wallbox mit Limit 11 kW gibt zu hohen Maximalstromwert zurück
#60
chk2902
closed
3 years ago
1
MQTT client ID
#59
t-mon
opened
3 years ago
1
API V1 mit Hardware V3
#57
chk2902
closed
3 years ago
4
Fehler API V1 mit Hardware V3
#56
chk2902
closed
3 years ago
11
Please update API with needed firmware + HW version information
#55
sigma415
opened
3 years ago
2
New Commands/Registers for Hardware V3 documentation needed
#54
chk2902
closed
3 years ago
5
MQTT sessionChargeEnergyLimit unterstützt keine Nachkommastellen
#53
ako-3004
opened
3 years ago
0
Ist Eigenverbruach der Box in 'eto' enthalten?
#52
mat-fu
closed
3 years ago
2
RFID beim Überschussladen
#51
fuchs-1978
opened
3 years ago
3
cURL: Operation timed out
#50
kaufi88
closed
3 years ago
6
AMX setting: Which firmware version ?
#49
sigma415
closed
3 years ago
2
Genauigkeit 'eto'
#48
Chringbay
opened
3 years ago
7
DWS reset: Wie und wann?
#47
tuxedo0801
opened
3 years ago
0
Update go-eCharger Modbus TCP API v1 DE.md
#46
Bernd-G
opened
3 years ago
0
AMX-Wert darf nur Ganzzahlig (6..32) sein?
#45
uklatt
closed
3 years ago
7
Fronius Wattpilot
#44
geowiwi
closed
3 years ago
8
Eindeutiger hostname?
#43
tuxedo0801
opened
3 years ago
5
Welchen Wertebereich kann AMX haben?
#42
Clemens-XXX
opened
3 years ago
1
Number of last scanned RFID card
#41
stefansommer
opened
3 years ago
0
Documentation for Modbus TCP/IP in english
#40
DotSlashSteve
closed
3 years ago
0
Code Beispiele hinzugefügt
#39
DotSlashSteve
closed
3 years ago
0
Update go-eCharger API v1 DE.md
#38
steffenknott
opened
3 years ago
1
Wert von AMX nicht in den MQTT Daten
#37
Dreistein19
opened
3 years ago
3
Signalstärke WLAN über API
#36
fuchs-1978
opened
3 years ago
0
Writing MQTT value locally
#35
torebrigaglia
closed
3 months ago
2
Button for own Use-Cases
#34
LichtiMC
opened
3 years ago
2
RST,ACK nach /status Abfrage führt zur Endlosschleife
#33
kaufi88
closed
3 years ago
2
Scheduler
#32
chk2902
opened
3 years ago
0
Wie kann ich die Box über den API neustarten?
#31
faxmaster
closed
3 years ago
3
Added txi as attribute
#30
MK-2001
closed
3 months ago
0
Register 315 korrigieren
#29
rootandy
closed
3 years ago
1
Optimierung der MODBUS Dokumentation
#28
rootandy
closed
3 years ago
1
Wie kann ich die Ladung über API komplett stoppen
#27
AlxBe
opened
3 years ago
8
Fehlende Angaben
#26
Tagiwara
opened
3 years ago
1
Local MQTT only available when Cloud activated?
#25
dzett
opened
3 years ago
1
How to decrypt api response
#24
tillschweneker
closed
3 years ago
7
Nachkommastellen bei AMP und AMX möglich?
#23
fuchs-1978
closed
3 years ago
2
some typos in go-eCharger API v1 EN.md
#22
hombach
closed
3 years ago
1
Some typos in "...v1 DE.md"
#21
hombach
closed
3 years ago
1
Neuer Parameter "amx" nicht im Status oder Set-Antwort
#20
hombach
closed
3 years ago
3
Typos and missing parameter in list of writeable parameters
#19
hombach
closed
3 years ago
1
Fixed some doc mistakes
#18
edgale
closed
3 years ago
1
Previous
Next