jsmithtx commented 8 months ago

Would love to see support for EG4 6000XP. Will download the code and see what I can do to help contribute.

gonzalop commented 8 months ago

If you can point me to documentation on connection type (RS232, RS485) and some details about the protocol, that would be helpful. For RS485+Modbus, if there's no documentation available, the modbus-read command can be useful to find out what registers are available.

Update: found it! https://eg4electronics.com/backend/wp-content/uploads/2023/10/EG4-6000XP-MODBUS-Communication-Protocol.pdf

There are a lot of registers but we could start by using modbus-read. I'll post a command for you to run that will read some data from the inverter and verify it works as expected. After this, I'll add some code to monitor-inverters to support fetching the most interesting data from the long list of registrs.

gonzalop commented 8 months ago

Download a release binary of wombatt for you system (windows, linux ARM/ARM64 for a Pi or linux AMD64 for intel), or build wombatt from source, then save the following lines to a file named format.txt:

u16:state
u16:pv1_voltage:V:0.01
u16:pv2_voltage:V:0.01
u16:pv3_voltage:V:0.01
u16:battery_voltage:V:0.1
u8:soc:%
u8:soh:%
u16:internal_fault
u16:pv1_power:W
u16:pv2_power:W
u16:pv3_power:W
u16:charging_power:W
u16:discharging_power:W

Now you need to connect the INV485 port (also try the 485A and 485B) to a RS485 to USB converter (i.e., something like https://www.amazon.com/Industrial-Bidirectional-Resettable-Protection-300bps-3MbpsBaudrateSupport/dp/B0B8DWLT1V/) and plug that converter to a computer.

Assuming the wombatt binary and the above file are in the same folder, and that the RS485 to USB converter shows as /dev/ttyUSB0 , run the following command:

./wombatt modbus-read -B 19200 --protocol ModbusRTU -O format.txt -p /dev/ttyUSB0 --id 1 --start 0 --count 12

If the output makes sense, we're on the right track and I'd need to make a couple of general-purpose changes to support Modbus in the monitor-inverter command, and then add a struct containing all the fields that you deem most relevant (or all?) to a new struct that will be used to read the modbus data into and display it or send it to MQTT.

jsmithtx commented 8 months ago

Do you have any thoughts about getting the data via an existing wireless/wired connection? Currently the device is connected to a private wired network (which is how it can send the data to the 'cloud' if I enabled it), so I wonder if there's a tcp command that can get the data.

gonzalop commented 8 months ago

I don't think that the dongle would expose the port directly, but you could try using 'nmap' to find open ports at the IP address assigned to the dongle and see if any of those ports might be it.

What I would try in this case is a main-in-the-middle approach. For this you need 4 RS485 to USB adapters and a Pi or other computer on which you can run commands and have the 2 adapters connected at the same time. One adapter goes to the inverter, the other adapter goes to the dongle. Then run the wombatt forward command and that will show you the data that goes back and forth between the inverter and the dongle. With a bit of luck, that data will use the same modbus protocol documented for the inverter and could be extracted without sending any actual request from the device inspecting the data.

jsmithtx commented 8 months ago

I did confirm with EG that the WLAN adapter does NOT support getting data.

Where would you connect the RS485 port to that adapter? The only port I know of is the battery comm, but I don't think it would chat about inverter data. I wonder what port I would use...

gonzalop commented 8 months ago

I don't own one, but the manual online says what to do in section 8.3 THIRD-PARTY RS485 COMMUNICATION: "Meters 485B and 485A can be used when a meteris not connected. These two pins can be used to communicate with the inverter using the RS485 Modbus protocol. INV485: This interface is shared with the Wi-Fi module. If the Wi-Fi module is not in use, this interface can be used to communicate with the inverter."

jsmithtx commented 8 months ago

Ah yes, I remember that part of the manual. I just need to open up mine and see where these 'meters' are at.

jsmithtx commented 8 months ago

GOT IT! When I took the adapter cover off, there are 4 wires... blue, red, white, and black

B - black wire A - white wire

And results...

wombatt.exe modbus-read -B 19200 --protocol ModbusRTU -O format.txt -p COM6 --id 1 --start 0 --count 12 State: 705 Pv1_voltage: 0.01V Pv2_voltage: 133.63V Pv3_voltage: 131.1V Battery_voltage: 1336.7V Soc: 50% Soh: 48% Internal_fault: 13361 Pv1_power: 25443W Pv2_power: 24929W Pv3_power: 2838W Charging_power: 267W Discharging_power: 0W

jsmithtx commented 8 months ago

If the output makes sense, we're on the right track and I'd need to make a couple of general-purpose changes to support Modbus in the monitor-inverter command, and then add a struct containing all the fields that you deem most relevant (or all?)

My one comment on the output is that the actual number values are incorrect (or very weird). Hopefully it is just an struct mismatch.

gonzalop commented 8 months ago

If the output makes sense, we're on the right track and I'd need to make a couple of general-purpose changes to support Modbus in the monitor-inverter command, and then add a struct containing all the fields that you deem most relevant (or all?)

My one comment on the output is that the actual number values are incorrect. Hopefully it is just an struct mismatch.

Right, I was about to say that some values look wrong. Can you run another command for me?

./wombatt modbus-read -B 19200 --protocol ModbusRTU -p COM6 --id 1 --start 0 --count 40

and let me know the output. That should help me writing tests and start fetching the most interesting values from the long list of registers.

It would also be very helpful if you can take a look at https://eg4electronics.com/backend/wp-content/uploads/2023/10/EG4-6000XP-MODBUS-Communication-Protocol.pdf at the table under "3. Register Mapping Table 1) Input register". For the first 40 registers, which will be fetched by the command above, try to provide as many known values as possible. I.e., if you know by other means the value of SOC and SOH, total PV production per string, their voltage, charging or discharging power, etc... This will help me narrow down any issues with the struct alignment.

Additional tests like trying ID 2 if you have a second inverter or seeing if lowering the baud rate to 9600 produces different values might also be helpful.

Thanks!

jsmithtx commented 8 months ago

Output from your command above (9600 baud returned nothing):


00000000  02 c1 00 01 34 33 33 36  34 37 32 30 34 31 63 63  |....4336472041cc|
00000010  61 61 0b 16 01 0b 00 00  02 18 12 06 11 15 00 01  |aa..............|
00000020  00 01 00 00 00 00 00 26  00 04 03 81 00 41 00 00  |.......&.....A..|
00000030  00 00 00 00 00 00 00 00  00 00 00 00 00 00 00 00  |................|
00000040  00 00 00 00 00 00 00 00  00 00 00 00 00 00 00 00  |................|```

Here is what I have so far -- note that ONLY PV1 has anything incoming -- PV2 is always 0; PV3 does not exist. I am not plugged in at all to the grid and there is no generator:

 0 
 1 Vpv1 264
 2 Vpv2 0
 3 Vpv3 0
 4 Vbat 52.5
 5 SOC  89%
 5 SOH     
 6 Fault 
 7 Ppv1 0.19 
 8 Ppv2 0
 9 PPV3 0
10 Pchar
11 Pdis 0.02 ?
12 VacR
13 VacS
14 VacT
15 Fac 
16 Pinv
17 Prec
18 Irms
19 PF  
20 VepsR
21 VepsS
22 VepsT
23 Feps 60.0 ?
24 Pesp
25 Seps
26 Ptogrid
27 Ptouser
28 Epv1_day 3.4
29 Epv2_day 0
30 Epv3_day 0
31 Einv_day
32 Erec_day
33 Echg_day
34 Edischg_day
35 Eeps_day
36 Etogrid_day
37 Etouser_day
jsmithtx commented 8 months ago

I thought I would get clever and write the hex int values out to see if I could correlate them, but it seems to have made it even worse. Here are the first 20:

No = register number (I am assuming two bytes for each register) HexBA - is the "inverted" hex value (the modbus says the high and low are swapped) BANo - this is the int hex value ANo - the int "A" value BNo - the int B value

The only one that looks reasonable is that 256 for PV1 voltage. But then 2 and 3 should be 0! And 5 should be around 89, not 48/50. Am I offset somewhere (like first 10 are something different)?


02 C1 00 01 34 33 33 36 34 37 32 30 34 31 63 63 61 61 0B 16 01 0B 00 00 02 18 01 07 25 14 00 01 00 01 00 00 00 00 00 26 00

No | HexBA  | BANo  | ANo | BNo
00 | 0xC102 | 49410 | 002 | 193
01 | 0x0100 | 00256 | 000 | 001
02 | 0x3334 | 13108 | 052 | 051
03 | 0x3633 | 13875 | 051 | 054
04 | 0x3734 | 14132 | 052 | 055
05 | 0x3032 | 12338 | 050 | 048
06 | 0x3134 | 12596 | 052 | 049
07 | 0x6363 | 25443 | 099 | 099
08 | 0x6161 | 24929 | 097 | 097
09 | 0x160B | 05643 | 011 | 022
10 | 0x0B01 | 02817 | 001 | 011
11 | 0x0000 | 00000 | 000 | 000
12 | 0x1802 | 06146 | 002 | 024
13 | 0x0701 | 01793 | 001 | 007
14 | 0x1425 | 05157 | 037 | 020
15 | 0x0100 | 00256 | 000 | 001
16 | 0x0100 | 00256 | 000 | 001
17 | 0x0000 | 00000 | 000 | 000
18 | 0x0000 | 00000 | 000 | 000
19 | 0x2600 | 09728 | 000 | 038
jsmithtx commented 8 months ago

The command you sent is reading the holding registers, not the input registers. I'm not sure what command to issue for those, but I found a modbus c# library and read the input registers and got (some) data that is actually meaningful (I was able to match the serial number of register 115, count 5)

Just need the modbus command to read the INPUT register

jsmithtx commented 7 months ago

Ok, good grief.. sorry to spam you. I finally got the numbers to match. I should not reverse the hex values even though I must reverse for the serial number -- no idea why!

This reading is taken at night-- and I think a lot of 0s because the inverter is UTC so new day.


00 40 00 00 00 00 0F 49 02 0D 00 57 00 00 00 00 00 00 00 00 00 00 00 9A 
00 00 00 00 18 01 00 00 00 00 00 00 00 5A 00 00 09 5F 27 40 50 52 17 6D 
00 92 00 B6 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 03 00 02 
00 00 00 00 0F 51 0E 88 08 83 00 00 00 00 00 00 00 00 00 00 00 00 00 00 
00 53 00 00 05 CE 00 00 03 B7 00 00 05 42 00 00 00 00 00 00 00 5A 00 00 
00 00 00 00 00 00 00 00 00 1A 00 24 00 27 00 1A 00 00 75 B2 00 37 00 00 
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 02 3A 98 75 30 02 30 
00 00 00 00 00 00 C0 00 00 00 00 00 12 00 AB BF 00 04 60 1C 00 85 00 03 
00 04 01 90 FE 98 00 00 00 00 0C FC 0C D2 00 E6 00 6E 02 12 00 01 02 12 
00 00 00 00 00 00 00 00 00 00 01 04 00 00 

No   |  AB-Hex  |  AB-Int |  A-Int  |  B-Int
000  |  0x0040  |  00064  |   000   |   064 // correct, 0x40 is "night" mode (battery only); Day will switch to C0 (second hex)
001  |  0x0000  |  00000  |   000   |   000
002  |  0x0000  |  00000  |   000   |   000
003  |  0x0F49  |  03913  |   015   |   073 // there is no PV3, I can only assume that it just makes stuff up
004  |  0x020D  |  00525  |   002   |   013 // correct, battery voltage is 52.5v (AB-Int)
005  |  0x0057  |  00087  |   000   |   087 // correct, SOC is 87% (B-Int)
006  |  0x0000  |  00000  |   000   |   000
007  |  0x0000  |  00000  |   000   |   000
008  |  0x0000  |  00000  |   000   |   000
009  |  0x0000  |  00000  |   000   |   000
010  |  0x0000  |  00000  |   000   |   000
011  |  0x009A  |  00154  |   000   |   154 // correct, discharge is around ~150w (AB-Int)
012  |  0x0000  |  00000  |   000   |   000
013  |  0x0000  |  00000  |   000   |   000
014  |  0x1801  |  06145  |   024   |   001
015  |  0x0000  |  00000  |   000   |   000
016  |  0x0000  |  00000  |   000   |   000
017  |  0x0000  |  00000  |   000   |   000
018  |  0x005A  |  00090  |   000   |   090
019  |  0x0000  |  00000  |   000   |   000
020  |  0x095F  |  02399  |   009   |   095
021  |  0x2740  |  10048  |   039   |   064
022  |  0x5052  |  20562  |   080   |   082
023  |  0x176D  |  05997  |   023   |   109
024  |  0x0092  |  00146  |   000   |   146
025  |  0x00B6  |  00182  |   000   |   182
026  |  0x0000  |  00000  |   000   |   000
027  |  0x0000  |  00000  |   000   |   000
028  |  0x0000  |  00000  |   000   |   000
029  |  0x0000  |  00000  |   000   |   000
030  |  0x0000  |  00000  |   000   |   000
031  |  0x0000  |  00000  |   000   |   000
032  |  0x0000  |  00000  |   000   |   000
033  |  0x0000  |  00000  |   000   |   000
034  |  0x0003  |  00003  |   000   |   003
035  |  0x0002  |  00002  |   000   |   002
036  |  0x0000  |  00000  |   000   |   000
037  |  0x0000  |  00000  |   000   |   000
038  |  0x0F51  |  03921  |   015   |   081
039  |  0x0E88  |  03720  |   014   |   136
...
096  |  0x0004  |  00004  |   000   |   004  //4 is correct
097  |  0x0190  |  00400  |   001   |   144  //400 correct
gonzalop commented 7 months ago

The first reply that you posted, starting with bytes "02 c1" seems like some kind of error response because the second byte has the highest bit set to 1.

You are correct and I should be using the 'Read Input Register' (0x04) command instead of the 'Read Holding Register' (0x03) command. That's an easy fix.

You're getting somewhere in this last message. How did you get that data? Specifically I'd like to know all the bytes sent to request it and all the bytes that were received, not just the register data bytes.

jsmithtx commented 7 months ago

Interesting note on the 0xC1, it should be C0. I'll have to pull a fresh check tomorrow when charging and see if it goes back to C0. I think it will; I had the battery comm messed up. An earlier communication had it as "00 C0".

I got the data the same way you are getting it, just using the input rather than holding registers. If I pull the "holding" ones I get the exact match to what wombatt returns.

I am using FluentModbus (nuget C# library);

using var client = new ModbusRtuClient()
{
    BaudRate = 19200,
    StopBits = StopBits.One,
    Parity = Parity.None
};
client.Connect("COM6", ModbusEndianness.LittleEndian);
var registers = client.ReadInputRegisters(0x01, 0, 40).ToArray();  // or .ReadHoldingRegisters(...)
jsmithtx commented 7 months ago

Ok, to follow up from last night, my holding numbers match exactly with your wombatt command. So whatever you are doing, if you change it to input registers (0x04), you'll probably get the same data below.

I dumped the data from 138 input registers (and snipped my serial number part out). For the data I could identify and matched correctly, I put a comment on the line with name=value. Some of the lines make no sense (marked with ?) -- weird values that seem wild.


Data at 2024-02-20T14:42:56 UTC:
00 C0 09 CA 00 00 0F 80 02 14 00 58 00 00 01 54 00 00 00 00 00 EF 00 00 00 00 00 00 18 01 00 00 00 00 00 00 00 64 00 00 09 78 27 40 20 02 17 71 00 26 00 26 00 00 00 00 00 02 00 00 00 00 00 00 00 00 00 00 00 0B 00 0C 00 00 00 00 0F 78 0E AF 00 E3 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 93 00 00 00 50 00 00 00 79 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 1F 00 2E 00 31 00 2B 00 00 36 CA 00 05 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 02 3A 98 75 30 02 30 00 00 00 00 00 00 C0 00 00 00 00 00 12 00 AB BF 00 00 60 1C 04 A5 00 03 00 04 01 90 01 5E 00 00 00 00 0D 09 0C FD 00 DC 00 6E 02 16 00 01 02 13 00 00 00 00 00 00 00 00 00 00 01 04 00 00 .. .. .. .. .. .. .. .. .. .. 07 CA 00 00 00 00 36 E0 02 00 7C C1 00 14 04 AF 04 BA 00 10 00 15 00 10 00 18 00 02 00 0B 00 10 00 00 00 6C

No   |  AB-Hex  |  AB-Int |  A-Int  |  B-Int
000  |  0x00C0  |  00192  |   000   |   192  // state = PV off-grid (0xC0)
001  |  0x09CA  |  02506  |   009   |   202  // vpv1 = 250.6v
002  |  0x0000  |  00000  |   000   |   000  // vpv2 = 0
003  |  0x0F80  |  03968  |   015   |   128  // vpv3 = ???? (does not exist)
004  |  0x0214  |  00532  |   002   |   020  // vbat = 53.2v
005  |  0x0058  |  00088  |   000   |   088  // SOC = 88%
006  |  0x0000  |  00000  |   000   |   000  // internal fault code = 0 (none)
007  |  0x0154  |  00340  |   001   |   084  // Ppv1 = 340w
008  |  0x0000  |  00000  |   000   |   000  // Ppv2 = 0
009  |  0x0000  |  00000  |   000   |   000  // Ppv3
010  |  0x00EF  |  00239  |   000   |   239  // Pcharge = 239w
011  |  0x0000  |  00000  |   000   |   000  // Pdisch = 0
012  |  0x0000  |  00000  |   000   |   000  // VacR
013  |  0x0000  |  00000  |   000   |   000  // VacS
014  |  0x1801  |  06145  |   024   |   001  // VacT  ???
015  |  0x0000  |  00000  |   000   |   000  // Fac
016  |  0x0000  |  00000  |   000   |   000  // Pinv
017  |  0x0000  |  00000  |   000   |   000  // Prec
018  |  0x0064  |  00100  |   000   |   100  // IinvRMS ??
019  |  0x0000  |  00000  |   000   |   000  // PF
020  |  0x0978  |  02424  |   009   |   120  // VepsR  ???
021  |  0x2740  |  10048  |   039   |   064  // VepsS ???
022  |  0x2002  |  08194  |   032   |   002  // VepsT  ???
023  |  0x1771  |  06001  |   023   |   113  // Feps = 60.01Hz
024  |  0x0026  |  00038  |   000   |   038  // Peps 
025  |  0x0026  |  00038  |   000   |   038  // Seps 
026  |  0x0000  |  00000  |   000   |   000  // Ptogrid = 0
027  |  0x0000  |  00000  |   000   |   000  // Ptouser = 0
028  |  0x0002  |  00002  |   000   |   002  // Epv1_day = 0.2kWh
029  |  0x0000  |  00000  |   000   |   000  // Epv2_day = 0
030  |  0x0000  |  00000  |   000   |   000  // Epv3_day = 0
031  |  0x0000  |  00000  |   000   |   000  // Einv_day = 0
032  |  0x0000  |  00000  |   000   |   000  // Erec_day = 0
033  |  0x0000  |  00000  |   000   |   000  // Echg_day = 0
034  |  0x000B  |  00011  |   000   |   011  // Edischg_day = 1.1kWh
035  |  0x000C  |  00012  |   000   |   012  // Eeps_day = 1.2kWh
036  |  0x0000  |  00000  |   000   |   000  // Etogrid_day = 0
037  |  0x0000  |  00000  |   000   |   000  // Etouser_day = 0
038  |  0x0F78  |  03960  |   015   |   120  // Vbus1  ??
039  |  0x0EAF  |  03759  |   014   |   175  // Vbus2  ??
040  |  0x00E3  |  00227  |   000   |   227  // Epv1_all L=22.7kWh
041  |  0x0000  |  00000  |   000   |   000
042  |  0x0000  |  00000  |   000   |   000
043  |  0x0000  |  00000  |   000   |   000
044  |  0x0000  |  00000  |   000   |   000
045  |  0x0000  |  00000  |   000   |   000
046  |  0x0000  |  00000  |   000   |   000
047  |  0x0000  |  00000  |   000   |   000
048  |  0x0000  |  00000  |   000   |   000
049  |  0x0000  |  00000  |   000   |   000
050  |  0x0093  |  00147  |   000   |   147  // Echg_all L=14.7kWh
051  |  0x0000  |  00000  |   000   |   000
052  |  0x0050  |  00080  |   000   |   080
053  |  0x0000  |  00000  |   000   |   000
054  |  0x0079  |  00121  |   000   |   121  // Eeps_all L=12.1kWh
055  |  0x0000  |  00000  |   000   |   000
056  |  0x0000  |  00000  |   000   |   000
057  |  0x0000  |  00000  |   000   |   000
058  |  0x0000  |  00000  |   000   |   000
059  |  0x0000  |  00000  |   000   |   000
060  |  0x0000  |  00000  |   000   |   000
061  |  0x0000  |  00000  |   000   |   000
062  |  0x0000  |  00000  |   000   |   000
063  |  0x0000  |  00000  |   000   |   000
064  |  0x001F  |  00031  |   000   |   031  // Tinner=31C
065  |  0x002E  |  00046  |   000   |   046  // Tr1=46C
066  |  0x0031  |  00049  |   000   |   049  // Tr2=49C
067  |  0x002B  |  00043  |   000   |   043  // TBat=43C
068  |  0x0000  |  00000  |   000   |   000
069  |  0x36CA  |  14026  |   054   |   202
070  |  0x0005  |  00005  |   000   |   005
071  |  0x0000  |  00000  |   000   |   000
072  |  0x0000  |  00000  |   000   |   000
073  |  0x0000  |  00000  |   000   |   000
074  |  0x0000  |  00000  |   000   |   000
075  |  0x0000  |  00000  |   000   |   000
076  |  0x0000  |  00000  |   000   |   000
077  |  0x0000  |  00000  |   000   |   000
078  |  0x0000  |  00000  |   000   |   000
079  |  0x0000  |  00000  |   000   |   000
080  |  0x0002  |  00002  |   000   |   002  // bat type,branch = 02
081  |  0x3A98  |  15000  |   058   |   152  // MaxChgCurr=150A
082  |  0x7530  |  30000  |   117   |   048  // MaxDischCurr=300A
083  |  0x0230  |  00560  |   002   |   048  // ChargeVoltRef=56.0
084  |  0x0000  |  00000  |   000   |   000  // DischgCutVolt=0
085  |  0x0000  |  00000  |   000   |   000
086  |  0x0000  |  00000  |   000   |   000
087  |  0xC000  |  49152  |   192   |   000
088  |  0x0000  |  00000  |   000   |   000
089  |  0x0000  |  00000  |   000   |   000
090  |  0x1200  |  04608  |   018   |   000
091  |  0xABBF  |  43967  |   171   |   191
092  |  0x0000  |  00000  |   000   |   000
093  |  0x601C  |  24604  |   096   |   028
094  |  0x04A5  |  01189  |   004   |   165
095  |  0x0003  |  00003  |   000   |   003
096  |  0x0004  |  00004  |   000   |   004
097  |  0x0190  |  00400  |   001   |   144  // BatCapacity=400Ah
098  |  0x015E  |  00350  |   001   |   094  // BatCurrent_BMS=3.5A
099  |  0x0000  |  00000  |   000   |   000
100  |  0x0000  |  00000  |   000   |   000
101  |  0x0D09  |  03337  |   013   |   009
102  |  0x0CFD  |  03325  |   012   |   253
103  |  0x00DC  |  00220  |   000   |   220
104  |  0x006E  |  00110  |   000   |   110
105  |  0x0216  |  00534  |   002   |   022
106  |  0x0001  |  00001  |   000   |   001
107  |  0x0213  |  00531  |   002   |   019
108  |  0x0000  |  00000  |   000   |   000
109  |  0x0000  |  00000  |   000   |   000
110  |  0x0000  |  00000  |   000   |   000
111  |  0x0000  |  00000  |   000   |   000
112  |  0x0000  |  00000  |   000   |   000
113  |  0x0104  |  00260  |   001   |   004
114  |  0x0000  |  00000  |   000   |   000
..snip..
120  |  0x07CA  |  01994  |   007   |   202  // VBusP  ??
121  |  0x0000  |  00000  |   000   |   000
122  |  0x0000  |  00000  |   000   |   000
123  |  0x36E0  |  14048  |   054   |   224  // no generator; numbers odd
124  |  0x0200  |  00512  |   002   |   000
125  |  0x7CC1  |  31937  |   124   |   193
126  |  0x0014  |  00020  |   000   |   020
127  |  0x04AF  |  01199  |   004   |   175  // EPSVoltL1N=119.9V
128  |  0x04BA  |  01210  |   004   |   186  // EPSVoltL2N=121.0V
129  |  0x0010  |  00016  |   000   |   016  // Peps_L1N=16w
130  |  0x0015  |  00021  |   000   |   021  // Peps_L2N=21w
131  |  0x0010  |  00016  |   000   |   016  // Seps_L1N=16VA
132  |  0x0018  |  00024  |   000   |   024  // Seps_L2N=24VA
133  |  0x0002  |  00002  |   000   |   002  // EepsL1N_day=0.2kWh
134  |  0x000B  |  00011  |   000   |   011  // EepsL2N_day=1.1kWh
135  |  0x0010  |  00016  |   000   |   016 
136  |  0x0000  |  00000  |   000   |   000
137  |  0x006C  |  00108  |   000   |   108
gonzalop commented 4 months ago

Note to self: use the changes in commit #846d4476f30dc742b20252bd459f641a57dbdcc4 to add a new protocol for monitor-inverters