Closed BluePaci closed 8 months ago
$338 is set to 7 to enable all Trinamic drivers? What is the output from M122? M122I?
Hi, 338 was set to 7, and the output was a no communication with driver error. But checking it did in fact solve my problem. It must require all axes to be enabled. setting it to 15, now enabling the A driver restored all power and motion to Y and Z. Not sure how healthy this is for the system though. Thanks for the help!
Hi, i've flashed the webbuild xPRO V5 firmware onto verified to be working hardware and only the X axis motors receive step pulses and power. Unsure of what the root cause is. happy to try potential solutions on my own hardware. I've checked that the pin map is correct and consistent with my existing fluidNC install, as well as config settings. (Going back to FluidNC fixes the issue)