gremau / NMEG_FluxProc

Code used to process and manage eddy covariance data for the New Mexico Elevation Gradient.
8 stars 2 forks source link

Radiation sensor calibration factor cleanup #15

Open gremau opened 9 years ago

gremau commented 9 years ago

Correct calibration factors for CNR1 and PPFD sensors at all sites

Calibration factors for CNR1 four component radiation systems and PPFD sensors are applied in the UNM_RBD_apply_radiation_calibration_factors.m script. Its likely that many of these are incorrect or applied to the wrong sensor data streams.

gremau commented 9 years ago

I am finding the correct (I think) calibration factors in the datalogger programs. In some cases the wrong calibration factor was applied to PPFD or CNR1 data for a number of years before being corrected in the new datalogger programs sent in January of 2014.