Closed MartinRJDagleish closed 2 years ago
Hi, the NMR mode requires Boltzmann factors to be available (or the free energy to compute them). If you start censo only with part4 and no previous part which can provide free energies, CENSO does not find the energy, solvation free energy, or GRRHO. I never thought about only running part4 and it seems to be a good idea to add a requirement that a previous part (any of part0-part3) has to be running before part4. Hope this helps.
Best,
Fabian
Hi, Thank you for your answer!
The way you phrased it CENSO can not find the previously calculated energies then, right? I had run CENSO with part0-2 in the same folder and I wanted to restart the calculation but only part4 because the calculations of the energies were done in the previous run already.
Does that mean I have to rerun the whole calcuation with part0-2 and part 4?
yes, rerun it with all previous parts on. CENSO keeps a record of already performed calculations and for those CENSO prints the results, rather than performing the calculations again. Then the Gibbs energy information is available for part4.
Ok thank you! I am going to try to rerun with all previous parts then.
Hey,
First of all the CREST + CENSO interface has worked very well.
I seem to have a problem though with my most recent calculation which I also can not seem to restart.
The error message is local variable 'energy' referenced before assignment
The Output file looks like this: