There hasn't been any activity on this issue recently, so we clean up some of the older and inactive issues. Please make sure to update to the latest version and check if that solves the issue. Let us know if that works for you by leaving a comment 👍 This issue has now been marked as stale and will be closed if no further activity occurs. Thanks!
Problem/Motivation
I tried to connect my UPS EATON with HA (Docker in a Virtual Machine in ESXI). I can start NUTS and aparently everything goes well, but when i go the the log file it seems that is having a permission problem. I share the log below:
6-rc: info: service s6rc-oneshot-runner: starting s6-rc: info: service s6rc-oneshot-runner successfully started s6-rc: info: service base-addon-banner: starting
Add-on: Network UPS Tools Manage battery backup (UPS) devices
Add-on version: 0.12.0 You are running the latest version of this add-on. System: Home Assistant OS 10.4 (amd64 / qemux86-64) Home Assistant Core: 2023.8.1 Home Assistant Supervisor: 2023.08.1
Please, share the above information when looking for help or support in, e.g., GitHub, forums or the Discord chat.
s6-rc: info: service base-addon-banner successfully started s6-rc: info: service fix-attrs: starting s6-rc: info: service base-addon-timezone: starting s6-rc: info: service base-addon-log-level: starting s6-rc: info: service fix-attrs successfully started [23:18:23] INFO: Configuring timezone (Europe/Lisbon)... s6-rc: info: service base-addon-log-level successfully started s6-rc: info: service base-addon-timezone successfully started s6-rc: info: service legacy-cont-init: starting cont-init: info: running /etc/cont-init.d/nut.sh [23:18:25] INFO: Setting mode to netserver... [23:18:25] INFO: Generating /etc/nut/upsd.users... [23:18:25] INFO: Configuring user: eaton [23:18:26] INFO: Password is NOT in the Have I Been Pwned database! Nice! [23:18:27] INFO: Configuring Device named myups... [23:18:27] INFO: Starting the UPS drivers... Network UPS Tools - Generic HID driver 0.47 (2.8.0) USB communication driver (libusb 1.0) 0.43 libusb1: Could not open any HID devices: insufficient permissions on everything No matching HID UPS found Network UPS Tools - UPS driver controller 2.8.0 Driver failed to start (exit status=1) cont-init: info: /etc/cont-init.d/nut.sh exited 1 cont-init: info: running /etc/cont-init.d/nutclient.sh cont-init: info: /etc/cont-init.d/nutclient.sh exited 0 cont-init: warning: some scripts exited nonzero s6-rc: warning: unable to start service legacy-cont-init: command exited 1 /run/s6/basedir/scripts/rc.init: warning: s6-rc failed to properly bring all the services up! Check your logs (in /run/uncaught-logs/current if you have in-container logging) for more information. /run/s6/basedir/scripts/rc.init: fatal: stopping the container. s6-rc: info: service fix-attrs: stopping s6-rc: info: service base-addon-timezone: stopping s6-rc: info: service base-addon-log-level: stopping s6-rc: info: service base-addon-timezone successfully stopped s6-rc: info: service base-addon-log-level successfully stopped s6-rc: info: service fix-attrs successfully stopped s6-rc: info: service base-addon-banner: stopping s6-rc: info: service base-addon-banner successfully stopped s6-rc: info: service s6rc-oneshot-runner: stopping s6-rc: info: service s6rc-oneshot-runner successfully stopped