laser exhaust system asks for maintenance #116

Closed LukasFreeze closed 7 years ago

LukasFreeze commented 7 years ago

Our exhaust system (VacuAir UML 500, not listed in cameo's selection anymore) has a flashing red/green light and the remote reads "Sichtkontrolle" or "Wartung Akt. Kohle" if you confirm having looked inside.

It appears this is more than just a "I've run for 100 h, please check me" thing, unfortunately there does not seem to be a manual... I'll get in touch with our technician and ask for one.

LukasFreeze commented 7 years ago

I got the manual as a pdf, if we really don't have a copy in the black binder under the laser I'll print it on Wednesday. Nothing on specific error messages, though...

LukasFreeze commented 7 years ago

I received the missing document after a nice chat with a cameo guy and know what to do, will print the manual tonight!

LukasFreeze commented 7 years ago

This remains more difficult than it should, it seems a passcode is required to access the relevant menu entry...I'll see if I can get that as well -.-

Pakue95 commented 7 years ago

The code worked! This unlocks the menu and you can check off "Sichtkontrolle" and other settings. I also checked off "Aktivekohle" as our filter is new and shouldn't need changing this early. Is was probably missed to reset in the factory.