Hi Mr Phil,
I'll not reply on your question as I don't know the module yet, sorry ;-)
But about the Xtender system I have experience. There exists an "independant" mode when you have multiple units: param 1462 With that mode you can have all three Xtenders working together on the same Studer-bus but not synchronized as if it would be in parrallel or in threephased. This will be OK if you have one battery and one BSP in a system as multi BSP is not possible.
Maybe that could fit your case
Regards
Hi moixpo Thanks a lot for the hint. I didn't know that. I would stick to the 3 independent battery systems, since that setup has also some advantages. especially if you have huge stack of lead-acid batteries that need a full load every couple of days, that maintenance load can be done independently. Regards, Phil
Hi, First of all, many thanks for providing this module. It works pretty well! My current setup is a bit overloaded. I run 3 xtender and each has its own Bus (xtender + BSP). With that setup, I currently have a Raspberry PI Zero for each xtender. Of course thats not ideal, especially because of maintenance, but also because of the power consumption and the coordination between the 3 xtenders (which needs another device). I would rather use one device (maybe a raspi 3 or 4) to communicate with all xtenders. So my question: is there a way to run multiple scom interfaces in parallel? e.g. xtender 1 runs on tty0, xtender 2 on tty1 etc. Since only one devicemanager and therefore one scom is initialized, I would say that's currently not possible.