Enphase Envoy Production Today sensor values after a power outage #118729

Closed ericstewart22 closed 1 week ago

ericstewart22 commented 1 month ago

The problem

After a power outage, the Enphase Envoy Energy Production Today sensor reports incorrect values of 5,000 kWh-16,000 kWh for a period of time. This causes issues with the energy dashboard. I would suggest that the output from this sensor pass through a range sensor for reasonable values.

What version of Home Assistant Core has the issue?

2024.5.5

What was the last working version of Home Assistant Core?

No response

What type of installation are you running?

Home Assistant Container

Integration causing the issue

Enphase Envoy

Link to integration documentation on our website

https://www.home-assistant.io/integrations/enphase_envoy/

Diagnostics information

Envoy Screenshot

Example YAML snippet

No response

Anything in the logs that might be useful for us?

No response

Additional information

No response

home-assistant[bot] commented 1 month ago

Hey there @bdraco, @cgarwood, @dgomes, @joostlek, @catsmanac, mind taking a look at this issue as it has been labeled with an integration (enphase_envoy) you are listed as a code owner for? Thanks!

Code owner commands Code owners of `enphase_envoy` can trigger bot actions by commenting: - `@home-assistant close` Closes the issue. - `@home-assistant rename Awesome new title` Renames the issue. - `@home-assistant reopen` Reopen the issue. - `@home-assistant unassign enphase_envoy` Removes the current integration label and assignees on the issue, add the integration domain after the command. - `@home-assistant add-label needs-more-information` Add a label (needs-more-information, problem in dependency, problem in custom component) to the issue. - `@home-assistant remove-label needs-more-information` Remove a label (needs-more-information, problem in dependency, problem in custom component) on the issue.

(message by CodeOwnersMention)


enphase_envoy documentation enphase_envoy source (message by IssueLinks)

catsmanac commented 1 month ago

Hi @ericstewart22, recommendation is to use the lifetime energy production value for the energy dashboard. Day values have been reported as less reliable and prone to surprises, like in your case.

DavidAtGoliathResearch commented 1 month ago

The problem

After a power outage, the Enphase Envoy Energy Production Today sensor reports incorrect values of 5,000 kWh-16,000 kWh for a period of time. This causes issues with the energy dashboard. I would suggest that the output from this sensor pass through a range sensor for reasonable values.

What version of Home Assistant Core has the issue?

2024.5.5

What was the last working version of Home Assistant Core?

No response

What type of installation are you running?

Home Assistant Container

Integration causing the issue

Enphase Envoy

Link to integration documentation on our website

https://www.home-assistant.io/integrations/enphase_envoy/

Diagnostics information

Envoy Screenshot

Example YAML snippet

No response

Anything in the logs that might be useful for us?

No response

Additional information

No response

In my case, it stopped receiving information. I was restarted Envoy to no avail. I know enabled debug logging on the integration...

catsmanac commented 1 month ago

Hi @DavidAtGoliathResearch, do you have the same problem (spikes in todays production after power outage) or a different one? From your description it sounds as if you can't connect to the envoy after power outage. If the first, make sure to use the lifetime energy production value in the Energy dashboard. If the latter please create a separate issue and not add a different issue here.

DavidAtGoliathResearch commented 1 month ago

Sorry, yesterday I couldn't even connect to the Envoy, but today I got information from yesterday and today. I still need to compare the information against Enlighten to see if they match. It is not the first time I suffered a power outage, but it was the first time Home Assistant stopped receiving information from my Envoy IQ7. So, even if the issue is not exactly the same, the reason was the same. If my values match, something I should know by the end of the day, I could create a different issue.

Thanks,

David


From: Arie Catsman @.> Sent: Wednesday, June 12, 2024 3:08 AM To: home-assistant/core @.> Cc: David Izada-Rodriguez @.>; Mention @.> Subject: Re: [home-assistant/core] Enphase Envoy Production Today sensor values after a power outage (Issue #118729)

Hi @DavidAtGoliathResearchhttps://github.com/DavidAtGoliathResearch, do you have the same problem (spikes in todays production after power outage) or a different one? From your description it sounds as if you can't connect to the envoy after power outage. If the first, make sure to use the lifetime energy production value in the Energy dashboard. If the latter please create a separate issue and not add a different issue here.

— Reply to this email directly, view it on GitHubhttps://github.com/home-assistant/core/issues/118729#issuecomment-2162269144, or unsubscribehttps://github.com/notifications/unsubscribe-auth/AS2FH7ZHV3GR7QCPSHV475DZG7XV5AVCNFSM6AAAAABIWUKKPSVHI2DSMVQWIX3LMV43OSLTON2WKQ3PNVWWK3TUHMZDCNRSGI3DSMJUGQ. You are receiving this because you were mentioned.Message ID: @.***>

catsmanac commented 3 weeks ago

@ericstewart22, @DavidAtGoliathResearch, as there's no further reply can we close this one?

DavidAtGoliathResearch commented 3 weeks ago

Sorry, after the last few days following the power outage, the connection to the Enphase panel failed for some reason and I found differences against Enlighten. With this information you can decide if the case should be closed.

Thanks,

David Izada Rodriguez

Get Outlook for Androidhttps://aka.ms/AAb9ysg


From: Arie Catsman @.> Sent: Saturday, June 22, 2024 5:10:32 AM To: home-assistant/core @.> Cc: David Izada-Rodriguez @.>; Mention @.> Subject: Re: [home-assistant/core] Enphase Envoy Production Today sensor values after a power outage (Issue #118729)

@ericstewart22https://github.com/ericstewart22, @DavidAtGoliathResearchhttps://github.com/DavidAtGoliathResearch, as there's no further reply can we close this one?

— Reply to this email directly, view it on GitHubhttps://github.com/home-assistant/core/issues/118729#issuecomment-2183955020, or unsubscribehttps://github.com/notifications/unsubscribe-auth/AS2FH7266FNF34PDGJLLFC3ZIU5QRAVCNFSM6AAAAABIWUKKPSVHI2DSMVQWIX3LMV43OSLTON2WKQ3PNVWWK3TUHMZDCOBTHE2TKMBSGA. You are receiving this because you were mentioned.Message ID: @.***>

catsmanac commented 1 week ago

@ericstewart22, what firmware is your Envoy running? If it's version 3.x there's a fix in the making. If the fw is newer I would need a debug log file with enphase_envoy debug enabled that catches a power outage/restart of the Envoy to apply a similar filter.

ericstewart22 commented 1 week ago

Thanks for following up. I have an IQ Gateway (SKU X-IQ-AM1-240-3-ES) and the firmware is D7.3.621. I am not sure if the fix in the making would apply to my device. The workaround/solution suggested above has been working for me for the time being, thankfully. In case it's useful, I have my device connected via ethernet so the communication should be very reliable.

catsmanac commented 1 week ago

Thanks for the feedback @ericstewart22. With your firmware version the solution is indeed to use the lifetime value, the day value has been reported multiple times with this awkward behavior.

catsmanac commented 1 week ago

@home-assistant close