Open delaineS opened 5 months ago
@delaineS A fix has been made to the upstream library IRremoteESP8266 v2.8.6 for COOLIX AC. This is reflected in Tasmota v13.1.0 and above. I'm not sure if it's related to this issue, but please try Tasmota v13.1.0 or above.
@nao-pon I didn't want to open a new topic cause my question is about a Toyotomi I have but registers as Coolpix in the mqtt.
I can control heat, cool, temperatures, swing vertical but I cannot set modes: auto, dry, fan. As far as I see everything is correct. Could it be the AC's fault ?
It just will not turn on if I initially choose auto, dry or fan. Not a big deal. ;)
@delaineS maybe you should check this also. My AC will turn on if I choose cool or heat and then auto, dry and fan work.
I followed your scheme, pressed ON on the remote control of my air conditioner, command read correctly by the Tasmota.
19:49:31.514 MQT: tele/Tasmota/RESULT = {"IrReceived":{"Protocol":"COOLIX","Bits":24,"Data":"0xB27BE0","DataLSB":"0x4DDE07","Repeat":0,"IRHVAC":{"Vendor":"COOLIX","Model":-1,"Command":"Control","Mode":"Off","Power":"Off","Celsius":"On","Temp":25,"FanSpeed":"Auto","SwingV":"Off","SwingH":"Off","Quiet":"Off","Turbo":"Off","Econo":"Off","Light":"Off","Filter":"Off","Clean":"Off","Beep":"Off","Sleep":-1,"iFeel":"Off","SensorTemp":null}}}
I resend the command and nothing Works
IRHVAC {"Vendor":"COOLIX","Model":-1,"Command":"Control","Mode":"Auto","Power":"On","Celsius":"On","Temp":28,"FanSpeed":"Auto","SwingV":"Off","SwingH":"Off","Quiet":"Off","Turbo":"Off","Econo":"Off","Light":"Off","Filter":"Off","Clean":"Off","Beep":"Off","Sleep":-1,"iFeel":"Off","SensorTemp":null}