hultenvp / solis-sensor

HomeAssistant integration for the SolisCloud PV Monitoring portal via SolisCloud API
Apache License 2.0
190 stars 41 forks source link

Phase specific measurements missing #360

Open jseppeli opened 3 months ago

jseppeli commented 3 months ago

Updated to latest version and now missing measurements in all the Solis grid phase measurements.

Solis

jseppeli commented 3 months ago

Tried to reconfigure the integration by deleting inverter and adding it back but no change.

VyckaLTU commented 3 months ago

Same is for me. I think it has problem with version 3.5.2. I reinstalled version 3.5.1 and everything works.

jseppeli commented 3 months ago

I also now did the same. 3.5.1 seems to work without issues.

hultenvp commented 3 months ago

Appears a side effect of moving to InverterDetailList (to fix #354). So daily energy charged/discharged doesn't work properly in InverterDetail and the Solis grid phase measurements apparently do not work in InverterDetailList... Let me see if I can do something about it and make both groups happy. For now, best indeed to stay on 3.5.1.

jseppeli commented 3 months ago

I'll stick to 3.5.1 then :) Appreciate the time you put into this @hultenvp!