I think the R404a might be unrelated, accidentally added a bug in my evaporator code.
I have identified the problem with R134a (critical region term), and will fix it (and other fluids that use the same code) this afternoon or tomorrow.
On 11/30/13, bachc notifications@github.com wrote:
Reopened #79.
Reply to this email directly or view it on GitHub: https://github.com/ibell/coolprop/issues/79
Fixed.
There seems to be some significant differences in the property calculations between r4.0.0 beta and r2.3. These result in about 12% difference in the Shah 2 phase evap HT coefficient (attached images). According to Ian this seems to be a result of the thermal conductivity calculations for R134a. I couldn't match my old evaporator calculations for R404a and think it might be related to the same issue for R404a.
Please check and fix. Thanks!