ibell / pdsim

Steady-State simulation code for positive displacement machines
MIT License
38 stars 25 forks source link

Fix initialization of CV for scroll #63

Closed ibell closed 4 years ago

ibell commented 4 years ago

The initial pressures all seem to be equal to suction pressure, which slows down convergence. They should be initialized with something like assumption of adiabatic compression.