icub-tech-iit / cad-libraries

In this repository we store the CAD libraries and the PTC Creo configuration files.
17 stars 9 forks source link

Harwin - R30-6700394 - Spacer, cylindrical, int.diam. 3.2mm, through hole, h=3mm, nylon #165

Closed Lawproto closed 4 months ago

Lawproto commented 9 months ago
Description Field
Datasheet component [see Wingst]
Project ergoCub lower arm
Alias Creo HARWIN_R30-6700394
IIT-Code 4591
Applicant Lorenzo Protopapa, @Lawproto
Supervisor Luca Fiorio, @fiorisi
Maintainer Marcello Savoldi, @marcellosavoldi
Coworkers @icub-tech-iit/silo-mech

Attachment:

Notes:

Checklist:

Complete the checklist in order to proceed with the request.

Lawproto commented 9 months ago

See commit above. Closing.

Mick3Lozzo commented 4 months ago

@Lawproto there are some problems with this component.

  1. In WinGST this component has not the correct alias.

image

  1. Another WinGST code, the 17485, stands for the same commercial component and has the correct alias, but its standardization is incomplete.

image

cc @Fabrizio69

Lawproto commented 4 months ago

@Mick3Lozzo it is a duplicated code. I say we just keep one of them, replace all the where used of the other and then delete it. Anyway, I suggest that the library component issue stay close since it is mostly unrelated to this problem.

Mick3Lozzo commented 4 months ago

@Lawproto I did a check and a component with a 4591 alias does not even exist, maybe I can correct the alias of this and make this one obsolete.

cc @Fabrizio69

Fabrizio69 commented 4 months ago

@Mick3Lozzo, cod.4591 is available in the warehouse:

image

cc: @Lawproto

Lawproto commented 4 months ago

@Fabrizio69 I checked, I please ask you to do this:

Everything will fall back into place.

Fabrizio69 commented 4 months ago

Done: deleted cod.17845

Miche19 commented 4 months ago

@Mick3Lozzo @Lawproto after a check, only 20 pieces of the code 4591 are present in the warehouse

Fixed real quantities in WinGst

cc: @Fabrizio69