idaholab / TMAP8

Tritium Migration Analysis Program, Version 8
https://mooseframework.inl.gov/TMAP8/
GNU Lesser General Public License v2.1
15 stars 21 forks source link

VV tests #12

Open lindsayad opened 3 years ago

lindsayad commented 3 years ago

We want to make sure that we've at least covered the VV tests from TMAP4. I believe that @simopier indicated he has some more VV tests to add as well. We should also add documentation for this so that users can view it on our website

@simopier: EDIT - Adding the full list of TMAP4 and TMAP7 V&V cases with names of who's working on which. This is meant to facilitate coordination.

Case name​ Case description Status or name
ver-1a​ Depleting Source Problem​
ver-1b​ Diffusion Problem with Constant Source Boundary Condition​
ver-1c​ Diffusion Problem with Partially Preloaded Slab​​
ver-1da​ Permeation Problem with Trapping​​
ver-1dd​ No Trapping (7)​​
ver-1dc​ Multiple Trap (7)​​
ver-1dd Permeation Problem without Trapping​​
ver-1e​ Diffusion in Composite Material Layers​​
ver-1fa​ Heat Conduction with Heat Generation​​
ver-1fb​ Thermal Transient​​
ver-1fc​ Conduction in Composite Structure with Constant Surface Temperatures​​
ver-1fd​ Convective Heating​​
ver-1g​ Simple Forward Chemical Reaction​​
ver-1gc​ Series Chemical Reactions​​
ver-1ha​ Convective Gas Outflow Problem​​
ver-1hb​ Equilibrating Enclosures (7)​​
ver-1ia​ Species Equilibration on a Reactive Surface - a (7)​
ver-1ib​ Species Equilibration on a Reactive Surface - b (7)​
ver-1ic​ Species Equilibration on a Reactive Surface - c (7)​
ver-1id​ Species Equilibration on a Reactive Surface - d (7)​
ver-1ie​ Species Equilibration on a Reactive Surface - e (7)​
ver-1if​ Species Equilibration on a Reactive Surface - f (7)​
ver-1ja​ Radioactive Decay of Mobile Tritium in a Slab​
ver-1jb​ Radioactive Decay of Mobile Tritium in a Slab with a Distributed Trap Concentration (7)​​
ver-1ka​ Enclosure Volumetric Source Rate - Simple (7)​
ver-1kb​ Enclosure Volumetric Source Rate - Henry (7)​
ver-1kc​ Enclosure Volumetric Source Rate - Sieverts 1 (7)​ @Lee01Atom @simopier
ver-1kd​ Enclosure Volumetric Source Rate - Sieverts 2 (7)​ @Lee01Atom @simopier
val-2a​ Ion Implantation Experiment (4+7)​​
val-2ba​ Diffusion Experiment in Beryllium​​
val-2bb​ Diffusion Experiment in Beryllium​​
val-2c​ Test Cell Release Experiment (4+7)​​
val-2d​ Thermal Desorption Spectroscopy on Tungsten ()​​ @lin-yang-ly
val-2e​ Co-permeation of H2 and D2 through Pd​​ @ke7kto

@chaibhave is also working on defining standards for the TMAP8 V&V cases, which will need to be followed: https://github.com/idaholab/TMAP8/issues/123.

simopier commented 3 years ago

The manual for TMAP7 describes more VV tests than the manual for TMAP4. It's a good place to look at!

lindsayad commented 2 years ago

@singhgp4321 feel free to check off the task list items in the title post of this issue if/as you address them