@moose-ncrc commented at Dec 12, 2022 02:19PM MST:
In GitLab by @kyriv1980 on Dec 12, 2022, 14:19
added 2 designs
@kyriv1980 commented at Feb 01, 2023 02:33PM MST:
@loganharbour Can you please close this issue? It has been resolved.
@loganharbour commented at Feb 01, 2023 02:50PM MST:
Closed by #292176
Issue closed at: Feb 01, 2023 02:50PM MST by @loganharbour
Imported from https://github.inl.gov/ncrc/subchannel/issues/72 : @moose-ncrc created issue at Dec 12, 2022 01:41PM MST:
In GitLab by @kyriv1980 on Dec 12, 2022, 13:41
Description of the error report
The post processor responsible for printing out a solution value at a point is not working properly. In contrast the corresponding Prost-processor for the quad geometry (QuadSubchannelPointValue) works like a charm.
Information for reproducing the error
Run this input file. FFM-3A.i The printed temperature value is the initial solution value, not the correct temperature after the problem has been solved. The solution for a center Subchannel, looks like the attached plot. The Subchannel indexes are also attached for user reference. So one would expect the printed value to be about 857K (same as the exit temperature in the plot).
Identified impact
The user needs to be able to print QOI like solution variables through the input file (post-processor) without the need to hard-code.