Closed vtorok closed 3 years ago
In the newer version we respect the local coordinate system of members from the original model. Check coordiante systems in your model, imported connections - they should be same. That is why the end and the begin are swapped
Hello, the bug has now been solved. The fix will be a part of the next patch coming this week.
Hi, It has been noticed that something has been changed in Idea between ver 20 and 20.1 regarding the export from Consteel to Idea. Consteel uses an XML file to export the parts of a connection to IDEA. It worked well in ver. 20 but in ver. 20.1 the signs of the exported forces are interchanged. The forces in ver. 20.1 are therefore not in equilibrium, too. See the attached pictures and files.
What has been modified in this field in IDEA since version 20? Was it needed or is it a bug maybe?
XML file and screenshots are attached.
2039-E61.csm - IDEA IOM.zip
Best regards, Vazul Török Consteel Solutions Ltd.