Closed italobusi closed 2 years ago
Dr. Zheng from China Unicom have a different idea about the model design. He prefers to define the inventory objects directly and follow the relationship like:
+inventory
+--equipment-rooms
| +--racks
| | +--shelves
| | | +--slots
| | | | +--subslots
| +--network-elements
| | +--boards
| | | +--ports
I have clarified that this issue applies with RFC8348 and created a new issue to track the discussion regarding Dr. Zheng proposal
It has been agreed to augment RFC8345 where the NE/nodes are contained within a network.
The examples have been developed under the assumption that there is only one top-level component within a NE/node
This assumption should be validated