Open matthiasdiener opened 2 years ago
✅ Reproduced with a weeks-old SingleGridWorkBalancing array context. Init seems to be working OK, but after the first step:
Pressure range violation (p_min=2528.236407762848, p_max=274270.23911909416)
health_pres_min: 2.65231e3
health_pres_max: 2.77231e5
I think we should just ignore this until @anderson2981 takes a look. In the meantime, as a workaround, the following changes to run_params.yaml
will make the tests step without running into health issues:
-current_dt: 1.0e-9
-t_final: 2.e-8
+current_dt: 1.0e-11
+t_final: 2.e-10
-health_pres_min: 2.65231e3
+health_pres_min: 2.3e3
smoke_test_injection_3d
fails the health check before the first step:The error happens for single-rank eager and lazy, with the current
main
branches (except mirgecom, which is on theproduction
branch).Pressure (and temperature) eventually become negative, after about 8 steps.
To reproduce:
smoke_test_3d
is also affected.