influxdata / telegraf

Agent for collecting, processing, aggregating, and writing metrics, logs, and other arbitrary data.
https://influxdata.com/telegraf
MIT License
14.6k stars 5.57k forks source link

I attach simplest possible telegraf consumer config pointing to public broker and yet i get this "error listening for Data". Please help! #10840

Closed alexanderlvov1 closed 2 years ago

alexanderlvov1 commented 2 years ago
# Configuration for telegraf agent
[agent]
  ## Default data collection interval for all inputs
  interval = "20s"
  ## Rounds collection interval to 'interval'
  ## ie, if interval="10s" then always collect on :00, :10, :20, etc.
  round_interval = true

  ## Telegraf will send metrics to outputs in batches of at most
  ## metric_batch_size metrics.
  ## This controls the size of writes that Telegraf sends to output plugins.
  metric_batch_size = 1000

  ## Maximum number of unwritten metrics per output.  Increasing this value
  ## allows for longer periods of output downtime without dropping metrics at the
  ## cost of higher maximum memory usage.
  metric_buffer_limit = 10000

  ## Collection jitter is used to jitter the collection by a random amount.
  ## Each plugin will sleep for a random time within jitter before collecting.
  ## This can be used to avoid many plugins querying things like sysfs at the
  ## same time, which can have a measurable effect on the system.
  collection_jitter = "0s"

  ## Default flushing interval for all outputs. Maximum flush_interval will be
  ## flush_interval + flush_jitter
  flush_interval = "10s"
  ## Jitter the flush interval by a random amount. This is primarily to avoid
  ## large write spikes for users running a large number of telegraf instances.
  ## ie, a jitter of 5s and interval 10s means flushes will happen every 10-15s
  flush_jitter = "0s"

  ## By default or when set to "0s", precision will be set to the same
  ## timestamp order as the collection interval, with the maximum being 1s.
  ##   ie, when interval = "10s", precision will be "1s"
  ##       when interval = "250ms", precision will be "1ms"
  ## Precision will NOT be used for service inputs. It is up to each individual
  ## service input to set the timestamp at the appropriate precision.
  ## Valid time units are "ns", "us" (or "µs"), "ms", "s".
  precision = ""

  ## Log at debug level.
  # debug = false
  ## Log only error level messages.
  # quiet = false

  ## Log target controls the destination for logs and can be one of "file",
  ## "stderr" or, on Windows, "eventlog".  When set to "file", the output file
  ## is determined by the "logfile" setting.
  # logtarget = "file"

  ## Name of the file to be logged to when using the "file" logtarget.  If set to
  ## the empty string then logs are written to stderr.
  # logfile = ""

  ## The logfile will be rotated after the time interval specified.  When set
  ## to 0 no time based rotation is performed.  Logs are rotated only when
  ## written to, if there is no log activity rotation may be delayed.
  # logfile_rotation_interval = "0d"

  ## The logfile will be rotated when it becomes larger than the specified
  ## size.  When set to 0 no size based rotation is performed.
  # logfile_rotation_max_size = "0MB"

  ## Maximum number of rotated archives to keep, any older logs are deleted.
  ## If set to -1, no archives are removed.
  # logfile_rotation_max_archives = 5

  ## Pick a timezone to use when logging or type 'local' for local time.
  ## Example: America/Chicago
  # log_with_timezone = ""

  ## Override default hostname, if empty use os.Hostname()
  hostname = ""
  ## If set to true, do no set the "host" tag in the telegraf agent.
  omit_hostname = false
[[outputs.influxdb_v2]]
  ## The URLs of the InfluxDB cluster nodes.
  ##
  ## Multiple URLs can be specified for a single cluster, only ONE of the
  ## urls will be written to each interval.
  ##   ex: urls = ["https://us-west-2-1.aws.cloud2.influxdata.com"]
  urls = ["https://eu-central-1-1.aws.cloud2.influxdata.com"]

  ## Token for authentication.
  token = "$INFLUX_TOKEN"

  ## Organization is the name of the organization you wish to write to; must exist.
  organization = "alexanderlvov1@gmail.com"

  ## Destination bucket to write into.
  bucket = "hive_open1"

  ## The value of this tag will be used to determine the bucket.  If this
  ## tag is not set the 'bucket' option is used as the default.
  # bucket_tag = ""

  ## If true, the bucket tag will not be added to the metric.
  # exclude_bucket_tag = false

  ## Timeout for HTTP messages.
  # timeout = "5s"

  ## Additional HTTP headers
  # http_headers = {"X-Special-Header" = "Special-Value"}

  ## HTTP Proxy override, if unset values the standard proxy environment
  ## variables are consulted to determine which proxy, if any, should be used.
  # http_proxy = "http://corporate.proxy:3128"

  ## HTTP User-Agent
  # user_agent = "telegraf"

  ## Content-Encoding for write request body, can be set to "gzip" to
  ## compress body or "identity" to apply no encoding.
  # content_encoding = "gzip"

  ## Enable or disable uint support for writing uints influxdb 2.0.
  # influx_uint_support = false

  ## Optional TLS Config for use on HTTP connections.
  # tls_ca = "/etc/telegraf/ca.pem"
  # tls_cert = "/etc/telegraf/cert.pem"
  # tls_key = "/etc/telegraf/key.pem"
  ## Use TLS but skip chain & host verification
  # insecure_skip_verify = false
# Read metrics from MQTT topic(s)
[[inputs.mqtt_consumer]]
  ## Broker URLs for the MQTT server or cluster.  To connect to multiple
  ## clusters or standalone servers, use a separate plugin instance.
  ##   example: servers = ["tcp://localhost:1883"]
  ##            servers = ["ssl://localhost:1883"]
  ##            servers = ["ws://localhost:1883"]
  servers = ["tcp://mqtt.fluux.io:1883"]
  ## Topics that will be subscribed to.
  topics = [
    "telegraf/host01/cpu",
    "telegraf/+/mem",
    "sensors/#",
  ]
  # topic_fields = "_/_/_/temperature"
  ## The message topic will be stored in a tag specified by this value.  If set
  ## to the empty string no topic tag will be created.
  # topic_tag = "topic"
  ## QoS policy for messages
  ##   0 = at most once
  ##   1 = at least once
  ##   2 = exactly once
  ##
  ## When using a QoS of 1 or 2, you should enable persistent_session to allow
  ## resuming unacknowledged messages.
  # qos = 0
  ## Connection timeout for initial connection in seconds
  # connection_timeout = "30s"
  ## Maximum messages to read from the broker that have not been written by an
  ## output.  For best throughput set based on the number of metrics within
  ## each message and the size of the output's metric_batch_size.
  ##
  ## For example, if each message from the queue contains 10 metrics and the
  ## output metric_batch_size is 1000, setting this to 100 will ensure that a
  ## full batch is collected and the write is triggered immediately without
  ## waiting until the next flush_interval.
  # max_undelivered_messages = 1000
  ## Persistent session disables clearing of the client session on connection.
  ## In order for this option to work you must also set client_id to identify
  ## the client.  To receive messages that arrived while the client is offline,
  ## also set the qos option to 1 or 2 and don't forget to also set the QoS when
  ## publishing.
  # persistent_session = false
  ## If unset, a random client ID will be generated.
  # client_id = ""
  ## Username and password to connect MQTT server.
  # username = "telegraf"
  # password = "metricsmetricsmetricsmetrics"
  ## Optional TLS Config
  # tls_ca = "/etc/telegraf/ca.pem"
  # tls_cert = "/etc/telegraf/cert.pem"
  # tls_key = "/etc/telegraf/key.pem"
  ## Use TLS but skip chain & host verification
  # insecure_skip_verify = false
  ## Data format to consume.
  ## Each data format has its own unique set of configuration options, read
  ## more about them here:
  ## https://github.com/influxdata/telegraf/blob/master/docs/DATA_FORMATS_INPUT.md
  data_format = "influx"
  ## Enable extracting tag values from MQTT topics
  ## _ denotes an ignored entry in the topic path
  ## [[inputs.mqtt_consumer.topic_parsing]]
  ##  topic = ""
  ##  measurement = ""
  ##  tags = ""
  ##  fields = ""
  ## [inputs.mqtt_consumer.topic_parsing.types]
  ##
telegraf-tiger[bot] commented 2 years ago

Hello! I recommend posting this question in our Community Slack or Community Page, we have a lot of talented community members there who could help answer your question more quickly. Heads up, this issue will be automatically closed after 7 days of inactivity. Thank you!

telegraf-tiger[bot] commented 2 years ago

Hello! I am closing this issue due to inactivity. I hope you were able to resolve your problem, if not please try posting this question in our Community Slack or Community Page. Thank you!