Closed GoogleCodeExporter closed 9 years ago
I am adding these two choices. Note that the F-factor assignments for
below-grade floors will be the same as the slab-on-grade floors, since we don't
have any separate F-factors defined for below-grade floors.
ALSO NOTE! I am recommending a bit of a change and simplfiication to be
consistent with the other building envelope baseline rules: baseline floor is
always unheated slab-on-grade or unheated below-grade floor. This makes for a
more stable baseline. Baseline construction is the same, but with "No
Insulation" for an F-factor of 0.73. Let me know if this poses any problems
with the software. I don't think it will have a significant energy impact,
given that the baseline heated slab-on-grade floors were only slightly higher,
but I prefer to be consistent with the other envelope components.
Original comment by JohnJArent
on 28 May 2013 at 9:15
Verified changes to NACM. Revising owner to RHi for implementation in rules.
Original comment by da...@360-analytics.com
on 24 Sep 2013 at 9:52
Changing owner to Noah.
Noah, can you verify that the rules are consistent with the above?
Original comment by rhedr...@archenergy.com
on 15 Oct 2013 at 4:24
Fixed the CheckCode within the OpaqueEnvelope-UndergroundSurfaces.rule as well
as the FFactor table lookup bug.
Original comment by ncz...@archenergy.com
on 18 Nov 2013 at 9:58