Defect Description :
In the experiment section of "Instrumentation and working principles of solutions infra red spectroscopy" experiment, the position for the movable mirror is differing.
Actual Result :
In the experiment section of "Instrumentation and working principles of solutions infra red spectroscopy" experiment, the position for the movable mirror is differing. The mirror is positioned at a little top and came back to desired position once the movement is stopped.
The issue persisted with the functionality of both the scenarios 2methyl Benzoicacid and 2-nitrophynol.
Defect Description : In the experiment section of "Instrumentation and working principles of solutions infra red spectroscopy" experiment, the position for the movable mirror is differing.
Actual Result : In the experiment section of "Instrumentation and working principles of solutions infra red spectroscopy" experiment, the position for the movable mirror is differing. The mirror is positioned at a little top and came back to desired position once the movement is stopped.
The issue persisted with the functionality of both the scenarios 2methyl Benzoicacid and 2-nitrophynol.
Environment : OS: Windows 7, Ubuntu-16.04,Centos-6 Browsers:Firefox-42.0,Chrome-47.0,chromium-45.0 Bandwidth : 100Mbps Hardware Configuration:8GBRAM , Processor:i5
Attachments: