Open MacB19 opened 1 year ago

MacB19 commented 1 year ago

Would it be possible to add some more data on BYD HVS in standard adapter ? Here is the result of a simple "readable" poll: (http://192.168.178.88/components/readable)

Specially the following data can be imho very usefull: "BAT_TEMPERATURE_CELL_F64" : 24.0, "BAT_TEMPERATURE_CELL_MAX_F64" : 25.0, "BAT_TEMPERATURE_CELL_MIN_F64" : 23.0, ... "BAT_VALUE_STATE_OF_HEALTH_RELATIVE_U16" : 99.0, ... "DEVICE_TEMPERATURE_AMBIENTEMEAN_F32" : 26.0 ...

... ... "16580608" : { "attributes" : { ".simple-version-field" : "BYD2;10000;53490001;3.18", "[ENABLE]" : "true", "[VISIBLE]" : "true", "addr" : "21", "connection" : "{\"id\":\"rtu-generic-storage_/dev/rtu0\",\"name\":\"modbus-rtu-hub\",\"protocol\":\"ModbusRTU\",\"rtu-interface\":\"/dev/rtu0\",\"socket\":\"/tmp/modbus-rtu-hub.rtu0.uds\"}\n", "createTS" : "1676014641", "group-id" : "generic-storage-group", "has_internal_dcdc" : "false", "hwversion" : "5.0", "id" : "rtu-generic-storage/dev/rtu0@21", "if" : "modbus-rtu-hub;/dev/rtu0", "internal_dcdc_is_configurable" : "false", "manufacturer" : "BYD", "max_udc" : "467.2", "min_udc" : "320", "model" : "BYD Battery-Box Premium HV", "nameplate" : "{\"capacity_wh\":10240,\"manufacturer\":\"BYD\",\"max_power_charge_w\":10240,\"max_power_discharge_w\":10240,\"max_soc\":100,\"max_udc\":467,\"min_soc\":5,\"min_udc\":320,\"model\":\"BYD Battery-Box Premium HV\",\"module_number\":1,\"peak_power_charge_sec\":10,\"peak_power_charge_w\":13312,\"peak_power_discharge_sec\":10,\"peak_power_discharge_w\":13312,\"serial\":\"P030T020Z2211110601 \"}\n", "protocol_version_major" : "1", "protocol_version_minor" : "0", "serial" : "P030T020Z221111xxx ", "storage_interface_id" : "0x53490001", "sw_version" : "3.18" }, "channels" : { "BAT_CURRENT_DC_F64" : 0.69876139284879646, "BAT_CURRENT_DC_INTERNAL_F64" : 0.6994152046783626, "BAT_ENERGYACTIVE_ESTIMATION_MAX_CAPACITY_F64" : 35982000.0, "BAT_ENERGYACTIVE_LIFETIME_CHARGED_F64" : 2975310000.0, "BAT_ENERGYACTIVE_LIFETIME_DISCHARGED_F64" : 2414844000.0, "BAT_ENERGYACTIVE_MAX_CAPACITY_F64" : 36493200.0, "BAT_MODE_CELL_STATE_U16" : 3.0, "BAT_MODE_HYBRID_OPERATING_STATE_U16" : 1.0, "BAT_MODE_LAST_FAULT_PARAMETER_U16" : 0.0, "BAT_MODE_STATE_U16" : 0.0, "BAT_MODE_U16" : 2.0, "BAT_MODE_WAKE_ENABLE_STATUS_U16" : 1.0, "BAT_TEMPERATURE_CELL_F64" : 24.0, "BAT_TEMPERATURE_CELL_MAX_F64" : 25.0, "BAT_TEMPERATURE_CELL_MIN_F64" : 23.0, "BAT_VALUE_STATE_OF_CHARGE_RELATIVE_U16" : 98.599999999999994, "BAT_VALUE_STATE_OF_HEALTH_RELATIVE_U16" : 99.0, "BAT_VALUE_WARNING_CODE_U16" : 46.0, "BAT_VOLTAGE_DC_INTERNAL_F64" : 427.5, "COMPONENTS_MODE_ENABLE_U16" : 1.0, "COMPONENTS_MODE_VISIBLE_U16" : 1.0, "COMPONENTS_TIME_STAMP_U64" : 1692020116.0, "DCLINK_POWERACTIVE_LIMIT_DISCHARGE_F64" : 10944.0, "DCLINK_POWERACTIVE_MAX_F32" : 11020.0, "DCLINK_VOLTAGE_MEAN_F32" : 427.89999999999998, "DEVICE_TEMPERATURE_AMBIENTEMEAN_F32" : 26.0 } }, .... ...

My System: { "Body" : { "Data" : { "Inverter" : { "1" : { "DT" : 1, "Serial" : "33497xxx" } }, "Meter" : { "0" : { "DT" : -1, "Serial" : "1836451xxx" } }, "Ohmpilot" : {}, "Storage" : { "0" : { "DT" : -1, "Serial" : "P030T020Z2211110601 " } } } }, "Head" : { "RequestArguments" : { "DeviceClass" : "System" }, "Status" : { "Code" : 0, "Reason" : "", "UserMessage" : "" }, "Timestamp" : "2023-08-14T13:40:26+00:00" } }