Closed mbhomie007 closed 1 year ago
@frankjoke
Wird noch an dem Adapter gearbeitet? Bitte um kurze Rückmeldung.
Hi all, verwende zwar kein ioBrocker aber konnte das buderus2mqtt (https://github.com/krambox/buderus2mqtt) anpassen um mit meiner Logavent HRV2-350 (KM200 HRV) zu sprechen. Eventuell hilft es... Ich habe ein 2-ten Docker Container erstellt:
version: "3.7"
services:
######################
buderus_mqtt:
image: krambox/buderus2mqtt
container_name: logavent_mqtt
environment:
- KM200_url=mqtt://mqtt IP
- KM200_config=/data/config.yml
- KM200_passcode=AES Key
- KM200_km200=KM200HRV IP
volumes:
- km200data:/data
restart: unless-stopped
####################
volumes:
km200data:
driver_opts:
type: "nfs4"
o: "addr=nfs-server IP,nolock,soft,rw"
device: ":/data/docker_nfs/logavent/data"
Die config.yml:
measurements:
- url: '/ventilation/firmwareVersion'
- url: '/ventilation/unitName'
- url: '/ventilation/unitType'
- url: '/ventilation/unitComponents'
- url: '/ventilation/hacComponents'
- url: '/ventilation/switchPos'
- url: '/ventilation/operationModes'
- url: '/ventilation/workingTime'
- url: '/ventilation/fan'
- url: '/ventilation/sensor'
- url: '/ventilation/filter'
- url: '/ventilation/bypass'
- url: '/ventilation/preheater'
- url: '/ventilation/update'
- url: '/ventilation/service'
- url: '/ventilation/operationModes/enabledModes'
- url: '/ventilation/operationModes/activeMode'
- url: '/ventilation/operationModes/demand'
- url: '/ventilation/operationModes/manual'
- url: '/ventilation/operationModes/switchProgram'
- url: '/ventilation/operationModes/away'
- url: '/ventilation/operationModes/night'
- url: '/ventilation/operationModes/fireplace'
- url: '/ventilation/operationModes/bypass'
- url: '/ventilation/operationModes/demand/enable'
- url: '/ventilation/operationModes/demand/rhThreshold'
- url: '/ventilation/operationModes/demand/vocThreshold'
- url: '/ventilation/operationModes/demand/co2Threshold'
- url: '/ventilation/workingTime/totalSystem'
- url: '/ventilation/workingTime/totalInstallation'
- url: '/ventilation/fan/currentFanSpeed'
- url: '/ventilation/fan/supplyNominal'
- url: '/ventilation/fan/extractNominal'
- url: '/ventilation/fan/currentSupply'
- url: '/ventilation/fan/currentExtract'
- url: '/ventilation/sensor/outdoorTemp'
- url: '/ventilation/sensor/supplyTemp'
- url: '/ventilation/sensor/extractTemp'
- url: '/ventilation/sensor/exhaustTemp'
- url: '/ventilation/sensor/remoteTemp'
- url: '/ventilation/sensor/vocValue'
- url: '/ventilation/sensor/rhValue'
- url: '/ventilation/sensor/vocPollution'
- url: '/ventilation/filter/remainingTime'
- url: '/ventilation/filter/periodTime'
- url: '/ventilation/filter/reset'
- url: '/ventilation/bypass/state'
- url: '/ventilation/bypass/minOutsideTemp'
- url: '/ventilation/bypass/maxInsideTemp'
- url: '/ventilation/update/update'
- url: '/ventilation/update/request'
- url: '/ventilation/update/strategy'
- url: '/ventilation/operationModes/manual/enable'
- url: '/ventilation/operationModes/manual/fanSetpoint'
Ich habe aus dieser config die Datenpunkte /system und /gateway weggelassen ... hauptsächlich weil /gateway/firmware ein Fehler produziert. Für mich sind beide Datenpunkte nicht relevant.
An dem Adapter wird leider schon lange nicht mehr gearbeitet.
Stattdessen bin ich mit dem Adapter voll zufrieden.
Auch die Lüftungsanlage ist integriert.
Adapter km200 is deprected. So this isse will be closed.
See #122
Hallo @frankjoke Ich habe folgenden Request. Vielleicht könnte dies integriert werden.
Ich benutze die Adapter Version 2.0.3.
Leider ist in dem Adapter das Buderus KM200 HRV Gateway für Logavent Lüftungsanlagen nicht integriert.
Die Daten lassen sich nicht richtig auslesen, einige Daten werden aber abgegriffen. Die Verbindung wurde erfolgreich über den Adapter hergestellt. Nur kann man mit den Daten nichts anfangen...
Habe eine Buderus HRV2 Lüftungsanlage in Verbindung mit dem KM200 HRV und der Buderus App "My Vent".
Produkt: https://www.buderus.de/de/produkte/catalogue/alle-produkte/7719_gateway-logamatic-web-km100-km200-km200-hrv
Ich bin gerne bereit bei der Integrierung zu unterstützen und zu testen.