ipbus / ipbus-firmware

Firmware that implements a reliable high-performance control link for particle physics electronics, based on the IPbus protocol
https://ipbus.web.cern.ch
Other
41 stars 32 forks source link

Bug in register slave strobe signal #26

Closed dmnewbold closed 6 years ago

dmnewbold commented 7 years ago

There is an accidental latch in ipbus_ctrlreg_v strobe output signal, which can cause the strobe to latch high under some conditions. Also, ipbus_reg_v should have a strobe output signal for consistency with ipbus_ctrlreg_v and ipbus_syncreg_v.

tswilliams commented 6 years ago

All done, by @dmnewbold . Closing.