How to tutorial: mistake in pumped hydro instructions? #159
Closed
amnanni closed 6 months ago
In the last part, shouldn't these be just for unit_inputNodes?
" And setting parameters for unit_outputNode and unit_inputNode:
(hydro_pump | nodeA) constraint_flow_coefficient Map: plant_storage_nodeA_split , 2 (hydro_pump | pump_storage) constraint_flow_coefficient Map: plant_storage_nodeA_split , -1 "