Routes of administration: Injection (IV, IM, SC, etc): Loss of 0.1 mL from Luer taper #12

Open davidhedlund opened 1 year ago

davidhedlund commented 1 year ago

"About 0.1 mL of the solution is lost in conventional syringes through the Luer taper tip and the Luer taper adapter of the hypodermic needle. That can be compensated by either adding extra 10% or 5% substance in 1 mL or 2 mL syringes respectively, or by using low dead space syringes."

Title: Routes of administration Author: David Hedlund Source: https://psychonautwiki.org/wiki/Routes_of_administration License: Creative Commons Attribution-ShareAlike 4.0 International