Internal clock of Treequencer & Smute never align with other clocked systems on startup #66

Closed isivisi closed 8 months ago

isivisi commented 9 months ago

Smute & Treequencer clocks never seem to initially line up with other sequencers / clocked tools in vcvrack on startup. running all modules through a reset at the same time fixes this but its weird behavior.

Don't know what is causing this yet.

isivisi commented 8 months ago

they have a 0.001 delay before accepting clock triggers after a reset https://vcvrack.com/manual/VoltageStandards#Timing