Closed jpnielsen closed 1 month ago
Hi. Sorry for the late reply. Thanks for the report. That is definitely not good...
We have tried to replicate this deleting both the sending (left) and the receiving (right) cvOSCcv modules and have not had it crash yet. It doesn't crash with the default send rate at 100 Hz or at 1000 Hz either.
I tried on the free version of VCV Rack (just using Fundamental modules with it). j4s0n tried on the Pro version with all the same modules in the image except for the scope you used.
What OS are you using? And do you have the save file for this patch? Are you able to consistently replicate this? Can you replicate it with just simple modules (like VCV Rack Fundamental, in case we don't have all the same modules)? If you could upload a save file where this happens for you, we can hopeful get it to crash on us too.
I forgot to see your reply - sorry about that.
On windows 11 22H2 (OS Build 22621.521) - using Rack Free 2.1.2
I can reproduce it: load the attached patch.
enable both cvOSCcv modules (observe the waveforms on the scope) right-click the cvOSCcv module to the right + select delete = crash
No error is logged in log.txt the patch file: cvosccv-loop_WIP.zip
Thank you for adding the "Send Frequency / Hz" option.
Thanks. I will try to look at it later tonight, but I'm working on a different project now.
Hi. This has been fixed in the latest release v2.0.6 and should update in the library in the next week or so.
I have a bug report.
Deleting the cvOSCcv module on the right, when it's "Enabled", crashes Rack2 pro standalone.
Also, I changed TROWA_OSCCV_DEFAULT_SEND_HZ to 1000 Please make the default send freq a runtime configurable option.
Thank you for making these plugins available. I use them frequently, and recommend them in the community forum:
https://community.vcvrack.com/t/ui-your-opinion-and-advice-appreciated/15713/6 https://community.vcvrack.com/t/thinking-about-purchasing-the-es-9/16228/10 https://community.vcvrack.com/t/bring-in-measurements-from-a-digital-multimeter/14557