Closed beelsebob closed 6 months ago
Yeah most likely an issue with Safari, it can be quite strange at times.
@beelsebob can you check Settings -> Dashbaord -> Temperature Gauges -> Bed Max Temp
?
Ahhh, you know I recon that's the issue - it appears that the default max is 100º, which is no good if you're going to start printing PC. That indication looks an awful lot like it's trying to indicate 4º. Perhaps there's a clamp
missing on the temperature somewhere, and a check to show some kind of warning if the temperature is off the scale?
Yeah, looks like that's it.
Done
I have created a fix, it will be included in the next release! If you want to try it out before then, you can install the development branch using this url:
https://github.com/j7126/OctoPrint-Dashboard/archive/development.zip
Please note that this branch may be unstable.
Thanks a lot!
The problem
The scaling of the bed temperature graph is weird for my Prusa Mk3. Here's an example while warming up to print PC-CF:
As you can see, it seems to be showing the range 100ºC - 1000ºC or something like that, rather than what I'd expect - something like 20ºC to 150ºC.
Doesn't occur when viewing in Firefox, so probably an issue with JS/Safari.
octoprint-systeminfo-20240218120259.zip
Version of OctoPrint
1.9.3
Platform
Raspberry Pi 4
Operating system running OctoPrint
OctoPi
Dashboard version
1.19.10
Python version
3.9.2
Printer model & used firmware incl. version
Prusa i3 Mk3s+, 3.1.12
Browser and version of browser, operating system running browser
macOS 14.2, Safari 17.2
Logs and other files needed for analysis
File uploads & additional information
No response