Closed slampt closed 7 years ago
You can e-mail me on: goodwelogger@forward.cat
Hi, I tried mailing you on the above address, but I got the following unhelpful error:
Failed recipient(s):
goodwelogger@forward.cat
Error message:
null
I was wondering if you had any idea how to connect if the inverter (GW10KN-DT) shows 2 pairs of RS485 connections, a RX and a TX pair. Are 2 RS485 interfaces needed?
Only one RS485 connection is needed. The second RS485 connection is for connecting to the next inverter so they can be daisy-chained. The forward e-mail address you've mailed is a temporary email address. Commenting and questions can be posted here.
There are 2 physical connectors, with each connector showing 2 pairs of RS485 pins. This is a grab of the installation manual where it's described: http://corky.wurtel.net/~paul/rs485-rj45-2.gif I'll have a look in person at the unit this weekend to see what's actually there :-)
Hi!
I’m interested in using this for a SolarRiver inverter. Would the implementation be the same?
Hello, not an issue but I wanted to get in touch and ask you a few questions about this logger via email.
Thanks!