Closed DMIINC closed 4 years ago
Hi
Yep - if you want to do it just for you - the approach is too add/change the json files in mpp-solar/commands folder (if you do it in the download copy you'll need to reinstall afterward)
For me to do it more generically would take a bit longer as I'd need to add a way to filter commands based on what device you have (though that is probably a good idea for the future)
Which file? Is it lot of typing. I have a daughter at the house with nothing to do due to virus. Is it mostly copy paste type of adding commands?
Thanks,
Depends what you want to change...
While the mpp-solar can do a summary for you with -s
etc. You can also just use the raw commands like -c QPIGS
, some of these are the same (e.g. QPIGS), some have changed a little (like QPGSn) and some are new (e.g. QPIGS2)
e.g. to update QPGSn you'd edit the mppsolar/commands/qpgs.json
(from the downloaded content)
to create support for a new command like QPIGS2 copy mppsolar/commands/qpigs.json
to mppsolar/commands/qpig2.json
and update the content
Then re-install the package with sudo python ./setup.py install
Hope this helps - if not let me know your priorities and I'll try to get time to look at implementing something
I really do I appreciate your help. But before we put a lot of work on this, what would be the easiest way to see if these commands can communicate with all 6 inverters. 2 per chassis for 3 chassis. All I can do now is one half of one chassis.
So what command is working now?
If you are using -s
, try -c QPIGS
then -c QPGS0
, and -c QPGS1
, and -c QPGS2
and let me see what you get
i@raspberrypi:~ $ sudo mpp-solar -c QPIGS -R (122.5 59.9 122.5 59.9 0539 0486 021 228 56.10 003 100 0036 0000 000.0 00.00 00000 0100010 00 00 00000 110�p pi@raspberrypi:~ $
pi@raspberrypi:~ $ sudo mpp-solar -c QPGS0 -R 2020-03-26 19:16:27,944 - MPP-Solar - mppcommand.py - ERROR - Response invalid as insufficient number of elements in response. Got 1, expected as least 27 (NAKss pi@raspberrypi:~ $ sudo mpp-solar -c QPGS0 2020-03-26 19:16:52,081 - MPP-Solar - mppcommand.py - ERROR - Response invalid as insufficient number of elements in response. Got 1, expected as least 27 pi@raspberrypi:~ $ i@raspberrypi:~ $ sudo mpp-solar -c QPIGS -R bash: i@raspberrypi:~: command not found
pi@raspberrypi:~ $ sudo mpp-solar -c QPI protocol_id PI41
what about sudo mpp-solar -c QPGS1 -R
?
I take it that you are using a USB to serial converter?
pi@raspberrypi:~ $ sudo mpp-solar -c QPGS1 -R 2020-03-26 19:33:02,609 - MPP-Solar - mppcommand.py - ERROR - Response invalid as insufficient number of elements in response. Got 1, expected as least 27 (NAKss
Same thing for additional numbers
Yes usb to serial
So, sudo mpp-solar -c QPIGS -R
works?
what about sudo mpp-solar -c QMOD
and sudo mpp-solar -c QDI
?
(coz QPGS0 should work accord to the doc you sent
pi@raspberrypi:~ $ sudo mpp-solar -c QMOD
device_mode Line
pi@raspberrypi:~ $ sudo mpp-solar -c QDI
ac_output_frequency 60.0 Hz
ac_output_voltage 120.0 V
battery_bulk_charge_voltage 56.4 V
battery_float_charge_voltage 54.0 V
battery_recharge_voltage 46.0 V
battery_redischarge_voltage 54.0 V
battery_type AGM
battery_under_voltage 42.0 V
buzzer enabled
charger_source_priority Solar + Utility
input_voltage_range Appliance
lcd_backlight enabled
lcd_reset_to_default enabled
max_ac_charging_current 0030 A
max_charging_current 60 A
output_mode parallel output
output_source_priority Utility first
over_temperature_restart disabled
overload_bypass disabled
overload_restart disabled
power_saving disabled
primary_source_interrupt_alarm enabled
pv_ok_condition As long as one unit of inverters has connect PV, parallel system will consider PV OK
pv_power_balance PV input max current will be the max charged current
record_fault_code disabled
unknown_value_in_response 000
Yes, on all 3 commands
Unless all of them need to be connected via usb or serial to raspberry pi
thats not what the doc says (i.e. it implies you can get details from any using QPGSn)
I've added a QP2GSn
command, can you install the latest from git and try mpp-solar -c QP2GS0 -M LV5048
and maybe mpp-solar -c QP2GS0 -M LV5048 -D
if it doesnt work
The new -M
command is to limit commands to inverters that support them
pi@raspberrypi:~ $ mpp-solar -c QP2GS0 -M LV5048
ERROR:MPP-Solar:Response invalid as insufficient number of elements in response. Got 1, expected as least 17
pi@raspberrypi:~ $ mpp-solar -c QP2GS0 -M LV5048 -D
INFO:MPP-Solar:command QP2GS0
INFO:MPP-Solar:Serial device used: /dev/ttyUSB0, baud rate: 2400
INFO:MPP-Solar:Loading commands for inverter model: LV5048
DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/f.json
DEBUG:MPP-Solar:Command F supported all inverters
INFO:MPP-Solar:... command F loaded for inverter model: LV5048
DEBUG:MPP-Solar:Generate full command for F
DEBUG:MPP-Solar:Calculating CRC for F
DEBUG:MPP-Solar:Generated CRC 29 2 2902
DEBUG:MPP-Solar:Full command: F)
DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/mchgc.json
DEBUG:MPP-Solar:Command MCHGC supported all inverters
INFO:MPP-Solar:... command MCHGC loaded for inverter model: LV5048
DEBUG:MPP-Solar:Generate full command for MCHGC
DEBUG:MPP-Solar:Calculating CRC for MCHGC
DEBUG:MPP-Solar:Generated CRC 9d a2 9da2
DEBUG:MPP-Solar:Full command: MCHGC��
DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/mnchgc.json
DEBUG:MPP-Solar:Command MNCHGC supported all inverters
INFO:MPP-Solar:... command MNCHGC loaded for inverter model: LV5048
DEBUG:MPP-Solar:Generate full command for MNCHGC
DEBUG:MPP-Solar:Calculating CRC for MNCHGC
DEBUG:MPP-Solar:Generated CRC 57 23 5723
DEBUG:MPP-Solar:Full command: MNCHGCW#
DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/muchgc.json
DEBUG:MPP-Solar:Command MUCHGC supported all inverters
INFO:MPP-Solar:... command MUCHGC loaded for inverter model: LV5048
DEBUG:MPP-Solar:Generate full command for MUCHGC
DEBUG:MPP-Solar:Calculating CRC for MUCHGC
DEBUG:MPP-Solar:Generated CRC bf 86 bf86
DEBUG:MPP-Solar:Full command: MUCHGC��
DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/pbcv.json
DEBUG:MPP-Solar:Command PBCV supported all inverters
INFO:MPP-Solar:... command PBCV loaded for inverter model: LV5048
DEBUG:MPP-Solar:Generate full command for PBCV
DEBUG:MPP-Solar:Calculating CRC for PBCV
DEBUG:MPP-Solar:Generated CRC 64 5a 645a
DEBUG:MPP-Solar:Full command: PBCVdZ
DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/pbdv.json
DEBUG:MPP-Solar:Command PBDV supported all inverters
INFO:MPP-Solar:... command PBDV loaded for inverter model: LV5048
DEBUG:MPP-Solar:Generate full command for PBDV
DEBUG:MPP-Solar:Calculating CRC for PBDV
DEBUG:MPP-Solar:Generated CRC fd cd fdcd
DEBUG:MPP-Solar:Full command: PBDV��
DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/pbft.json
DEBUG:MPP-Solar:Command PBFT supported all inverters
INFO:MPP-Solar:... command PBFT loaded for inverter model: LV5048
DEBUG:MPP-Solar:Generate full command for PBFT
DEBUG:MPP-Solar:Calculating CRC for PBFT
DEBUG:MPP-Solar:Generated CRC bb ed bbed
DEBUG:MPP-Solar:Full command: PBFT��
DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/pbt.json
DEBUG:MPP-Solar:Command PBT supported all inverters
INFO:MPP-Solar:... command PBT loaded for inverter model: LV5048
DEBUG:MPP-Solar:Generate full command for PBT
DEBUG:MPP-Solar:Calculating CRC for PBT
DEBUG:MPP-Solar:Generated CRC 2f 11 2f11
DEBUG:MPP-Solar:Full command: PBT/
DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/pcp.json
DEBUG:MPP-Solar:Command PCP supported all inverters
INFO:MPP-Solar:... command PCP loaded for inverter model: LV5048
DEBUG:MPP-Solar:Generate full command for PCP
DEBUG:MPP-Solar:Calculating CRC for PCP
DEBUG:MPP-Solar:Generated CRC 5c a4 5ca4
DEBUG:MPP-Solar:Full command: PCP\�
DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/pcvv.json
DEBUG:MPP-Solar:Command PCVV supported all inverters
INFO:MPP-Solar:... command PCVV loaded for inverter model: LV5048
DEBUG:MPP-Solar:Generate full command for PCVV
DEBUG:MPP-Solar:Calculating CRC for PCVV
DEBUG:MPP-Solar:Generated CRC af ec afec
DEBUG:MPP-Solar:Full command: PCVV��
DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/pepd.json
DEBUG:MPP-Solar:Command PEPD supported all inverters
INFO:MPP-Solar:... command PEPD loaded for inverter model: LV5048
DEBUG:MPP-Solar:Generate full command for PEPD
DEBUG:MPP-Solar:Calculating CRC for PEPD
DEBUG:MPP-Solar:Generated CRC 85 99 8599
DEBUG:MPP-Solar:Full command: PEPD��
DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/pf.json
DEBUG:MPP-Solar:Command PF supported all inverters
INFO:MPP-Solar:... command PF loaded for inverter model: LV5048
DEBUG:MPP-Solar:Generate full command for PF
DEBUG:MPP-Solar:Calculating CRC for PF
DEBUG:MPP-Solar:Generated CRC 26 bd 26bd
DEBUG:MPP-Solar:Full command: PF&�
DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/pgr.json
DEBUG:MPP-Solar:Command PGR supported all inverters
INFO:MPP-Solar:... command PGR loaded for inverter model: LV5048
DEBUG:MPP-Solar:Generate full command for PGR
DEBUG:MPP-Solar:Calculating CRC for PGR
DEBUG:MPP-Solar:Generated CRC b0 22 b022
DEBUG:MPP-Solar:Full command: PGR�"
DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/pop.json
DEBUG:MPP-Solar:Command POP supported all inverters
INFO:MPP-Solar:... command POP loaded for inverter model: LV5048
DEBUG:MPP-Solar:Generate full command for POP
DEBUG:MPP-Solar:Calculating CRC for POP
DEBUG:MPP-Solar:Generated CRC 19 c9 19c9
DEBUG:MPP-Solar:Full command: POP�
DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/popm.json
DEBUG:MPP-Solar:Command POPM supported all inverters
INFO:MPP-Solar:... command POPM loaded for inverter model: LV5048
DEBUG:MPP-Solar:Generate full command for POPM
DEBUG:MPP-Solar:Calculating CRC for POPM
DEBUG:MPP-Solar:Generated CRC d3 71 d371
DEBUG:MPP-Solar:Full command: POPM�q
DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/ppcp.json
DEBUG:MPP-Solar:Command PPCP supported all inverters
INFO:MPP-Solar:... command PPCP loaded for inverter model: LV5048
DEBUG:MPP-Solar:Generate full command for PPCP
DEBUG:MPP-Solar:Calculating CRC for PPCP
DEBUG:MPP-Solar:Generated CRC 29 9f 299f
DEBUG:MPP-Solar:Full command: PPCP)�
DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/ppvokc.json
DEBUG:MPP-Solar:Command PPVOKC supported all inverters
INFO:MPP-Solar:... command PPVOKC loaded for inverter model: LV5048
DEBUG:MPP-Solar:Generate full command for PPVOKC
DEBUG:MPP-Solar:Calculating CRC for PPVOKC
DEBUG:MPP-Solar:Generated CRC af 9 af09
DEBUG:MPP-Solar:Full command: PPVOKC�
DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/psdv.json
DEBUG:MPP-Solar:Command PSDV supported all inverters
INFO:MPP-Solar:... command PSDV loaded for inverter model: LV5048
DEBUG:MPP-Solar:Generate full command for PSDV
DEBUG:MPP-Solar:Calculating CRC for PSDV
DEBUG:MPP-Solar:Generated CRC 89 9e 899e
DEBUG:MPP-Solar:Full command: PSDV��
DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/pspb.json
DEBUG:MPP-Solar:Command PSPB supported all inverters
INFO:MPP-Solar:... command PSPB loaded for inverter model: LV5048
DEBUG:MPP-Solar:Generate full command for PSPB
DEBUG:MPP-Solar:Calculating CRC for PSPB
DEBUG:MPP-Solar:Generated CRC 14 9c 149c
DEBUG:MPP-Solar:Full command: PSPB�
DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/q1.json
DEBUG:MPP-Solar:Command Q1 supported all inverters
INFO:MPP-Solar:... command Q1 loaded for inverter model: LV5048
DEBUG:MPP-Solar:Generate full command for Q1
DEBUG:MPP-Solar:Calculating CRC for Q1
DEBUG:MPP-Solar:Generated CRC 1b fc 1bfc
DEBUG:MPP-Solar:Full command: Q1
DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/qboot.json
DEBUG:MPP-Solar:Command QBOOT supported all inverters
INFO:MPP-Solar:... command QBOOT loaded for inverter model: LV5048
DEBUG:MPP-Solar:Generate full command for QBOOT
DEBUG:MPP-Solar:Calculating CRC for QBOOT
DEBUG:MPP-Solar:Generated CRC b 88 b88
DEBUG:MPP-Solar:Full command: QBOOT
�
DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/qdi.json
DEBUG:MPP-Solar:Command QDI supported all inverters
INFO:MPP-Solar:... command QDI loaded for inverter model: LV5048
DEBUG:MPP-Solar:Generate full command for QDI
DEBUG:MPP-Solar:Calculating CRC for QDI
DEBUG:MPP-Solar:Generated CRC 71 1b 711b
DEBUG:MPP-Solar:Full command: QDIq
EBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/qflag.json DEBUG:MPP-Solar:Command QFLAG supported all inverters INFO:MPP-Solar:... command QFLAG loaded for inverter model: LV5048 DEBUG:MPP-Solar:Generate full command for QFLAG DEBUG:MPP-Solar:Calculating CRC for QFLAG DEBUG:MPP-Solar:Generated CRC 98 74 9874 DEBUG:MPP-Solar:Full command: QFLAG�t DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/qid.json DEBUG:MPP-Solar:Command QID supported all inverters INFO:MPP-Solar:... command QID loaded for inverter model: LV5048 DEBUG:MPP-Solar:Generate full command for QID DEBUG:MPP-Solar:Calculating CRC for QID DEBUG:MPP-Solar:Generated CRC d6 ea d6ea DEBUG:MPP-Solar:Full command: QID�� DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/qmchgcr.json DEBUG:MPP-Solar:Command QMCHGCR supported all inverters INFO:MPP-Solar:... command QMCHGCR loaded for inverter model: LV5048 DEBUG:MPP-Solar:Generate full command for QMCHGCR DEBUG:MPP-Solar:Calculating CRC for QMCHGCR DEBUG:MPP-Solar:Generated CRC d8 55 d855 DEBUG:MPP-Solar:Full command: QMCHGCR�U DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/qmod.json DEBUG:MPP-Solar:Command QMOD supported all inverters INFO:MPP-Solar:... command QMOD loaded for inverter model: LV5048 DEBUG:MPP-Solar:Generate full command for QMOD DEBUG:MPP-Solar:Calculating CRC for QMOD DEBUG:MPP-Solar:Generated CRC 49 c1 49c1 DEBUG:MPP-Solar:Full command: QMODI� DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/qmuchgcr.json DEBUG:MPP-Solar:Command QMUCHGCR supported all inverters INFO:MPP-Solar:... command QMUCHGCR loaded for inverter model: LV5048 DEBUG:MPP-Solar:Generate full command for QMUCHGCR DEBUG:MPP-Solar:Calculating CRC for QMUCHGCR DEBUG:MPP-Solar:Generated CRC 26 34 2634 DEBUG:MPP-Solar:Full command: QMUCHGCR&4 DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/qopm.json DEBUG:MPP-Solar:Command QOPM supported all inverters INFO:MPP-Solar:... command QOPM loaded for inverter model: LV5048 DEBUG:MPP-Solar:Generate full command for QOPM DEBUG:MPP-Solar:Calculating CRC for QOPM DEBUG:MPP-Solar:Generated CRC a5 c5 a5c5 DEBUG:MPP-Solar:Full command: QOPM�� DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/qp2gs.json DEBUG:MPP-Solar:Command QP2GSn supported by model LV5048 INFO:MPP-Solar:... command QP2GSn loaded for inverter model: LV5048 DEBUG:MPP-Solar:Generate full command for QP2GSn DEBUG:MPP-Solar:Calculating CRC for QP2GSn DEBUG:MPP-Solar:Generated CRC af 3e af3e DEBUG:MPP-Solar:Full command: QP2GSn�> DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/qpgs.json DEBUG:MPP-Solar:Command QPGSn supported all inverters INFO:MPP-Solar:... command QPGSn loaded for inverter model: LV5048 DEBUG:MPP-Solar:Generate full command for QPGSn DEBUG:MPP-Solar:Calculating CRC for QPGSn DEBUG:MPP-Solar:Generated CRC 84 e1 84e1 DEBUG:MPP-Solar:Full command: QPGSn�� DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/qpi.json DEBUG:MPP-Solar:Command QPI supported all inverters INFO:MPP-Solar:... command QPI loaded for inverter model: LV5048 DEBUG:MPP-Solar:Generate full command for QPI DEBUG:MPP-Solar:Calculating CRC for QPI DEBUG:MPP-Solar:Generated CRC be ac beac DEBUG:MPP-Solar:Full command: QPI�� DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/qpigs-lv.json DEBUG:MPP-Solar:Command QPIGS supported by model LV5048 INFO:MPP-Solar:... command QPIGS loaded for inverter model: LV5048 DEBUG:MPP-Solar:Generate full command for QPIGS DEBUG:MPP-Solar:Calculating CRC for QPIGS DEBUG:MPP-Solar:Generated CRC b7 a9 b7a9 DEBUG:MPP-Solar:Full command: QPIGS�� DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/qpigs.json DEBUG:MPP-Solar:Command QPIGS not supported on inverter LV5048 DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/qpigs2.json DEBUG:MPP-Solar:Command QPIGS2 supported by model LV5048 INFO:MPP-Solar:... command QPIGS2 loaded for inverter model: LV5048 DEBUG:MPP-Solar:Generate full command for QPIGS2 DEBUG:MPP-Solar:Calculating CRC for QPIGS2 DEBUG:MPP-Solar:Generated CRC 68 2d 682d DEBUG:MPP-Solar:Full command: QPIGS2h- DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/qpiri-lv.json DEBUG:MPP-Solar:Command QPIRI supported by model LV5048 INFO:MPP-Solar:... command QPIRI loaded for inverter model: LV5048 DEBUG:MPP-Solar:Generate full command for QPIRI DEBUG:MPP-Solar:Calculating CRC for QPIRI DEBUG:MPP-Solar:Generated CRC f8 54 f854 DEBUG:MPP-Solar:Full command: QPIRI�T DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/qpiri.json DEBUG:MPP-Solar:Command QPIRI not supported on inverter LV5048 DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/qpiws.json DEBUG:MPP-Solar:Command QPIWS supported all inverters INFO:MPP-Solar:... command QPIWS loaded for inverter model: LV5048 DEBUG:MPP-Solar:Generate full command for QPIWS DEBUG:MPP-Solar:Calculating CRC for QPIWS DEBUG:MPP-Solar:Generated CRC b4 da b4da DEBUG:MPP-Solar:Full command: QPIWS�� DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/qvfw.json DEBUG:MPP-Solar:Command QVFW supported all inverters INFO:MPP-Solar:... command QVFW loaded for inverter model: LV5048 DEBUG:MPP-Solar:Generate full command for QVFW DEBUG:MPP-Solar:Calculating CRC for QVFW DEBUG:MPP-Solar:Generated CRC 62 99 6299 DEBUG:MPP-Solar:Full command: QVFWb� DEBUG:MPP-Solar:Loading command information from /usr/local/lib/python2.7/dist-packages/mpp_solar-0.2.2-py2.7.egg/mppsolar/commands/qvfw2.json DEBUG:MPP-Solar:Command QVFW2 supported all inverters INFO:MPP-Solar:... command QVFW2 loaded for inverter model: LV5048 DEBUG:MPP-Solar:Generate full command for QVFW2 DEBUG:MPP-Solar:Calculating CRC for QVFW2 DEBUG:MPP-Solar:Generated CRC c3 f5 c3f5 DEBUG:MPP-Solar:Full command: QVFW2�� DEBUG:MPP-Solar:Searching for cmd 'QP2GS0' DEBUG:MPP-Solar:Matched: QP2GSn Value: 0 DEBUG:MPP-Solar:Generate full command for QP2GSn0 DEBUG:MPP-Solar:Calculating CRC for QP2GSn0 DEBUG:MPP-Solar:Generated CRC 4c 56 4c56 DEBUG:MPP-Solar:Full command: QP2GSn0LV INFO:MPP-Solar:SERIAL connection: executing QP2GSn Parallel Information inquiry -- example: QP2GS1 queries the values of various metrics from instance 1 of parallel setup Inverters (numbers from 0)
DEBUG:MPP-Solar:port /dev/ttyUSB0, baudrate 2400 DEBUG:MPP-Solar:Command execution attempt 1... DEBUG:MPP-Solar:serial response was: (NAKss DEBUG:MPP-Solar:Response length: 7 DEBUG:MPP-Solar:CRC resp 73 73 DEBUG:MPP-Solar:Calculating CRC for (NAK DEBUG:MPP-Solar:Generated CRC 73 73 7373 DEBUG:MPP-Solar:CRC calc 73 73 DEBUG:MPP-Solar:CRCs match ERROR:MPP-Solar:Response invalid as insufficient number of elements in response. Got 1, expected as least 17 INFO:MPP-Solar:Invalid response pi@raspberrypi:~ $
Weird - your inverter doesn't seem to respond to the new commands in the documentation, or the documentation is incorrrect? Maybe you have a 2 digit ID or the ID isnt 0-3?? Did it come with software?
Yes. Windows side. It is called watch power. https://usa-mpp-solar.com/manuals/Software/WatchPowerV1.13SP3(latest)/ and you can find Linux stuff on that link.
I know just weird. I have been pulling my hair out for last 4 weeks. Just can't figure it out.
Can you check the inverters to see what IDs are set Page39 of the user manual has some details https://usa-mpp-solar.com/manuals/LV5048%20split%20phase%20manual-20191024.pdf
They are set as they requested it. System is performing flawlessly.
So the dip switches have the IDs set to 0 and 1?
If you look at the diagram all three are set as they want them to be.
Dalibor Majksner Hera Realty 2444 Duluth Highway STE 203 Duluth GA 30097 404-710-4876
-------- Original message -------- From: jblance notifications@github.com Date: 3/27/20 8:32 PM (GMT-05:00) To: jblance/mpp-solar mpp-solar@noreply.github.com Cc: Dalibor Majksner dalibor@jcwon.com, Author author@noreply.github.com Subject: Re: [jblance/mpp-solar] Adding commands for LV5048. (#11)
So the dip switches have the IDs set to 0 and 1?
— You are receiving this because you authored the thread. Reply to this email directly, view it on GitHubhttps://github.com/jblance/mpp-solar/issues/11#issuecomment-605367539, or unsubscribehttps://github.com/notifications/unsubscribe-auth/AO4DWSXCIZIBEKNDBGWCBGTRJVASDANCNFSM4LUD7OBA.
Watch power app does see all three.
Nice setup I was meaning the ID number - was wondering if they were set to something other than 0,1,2 - the manual says it could be 0-7 and as long as they are all different everything will work
Yes they are different
Thanks,
Does the command QPIGS2 work?
i.e. mpp-solar -c QPIGS2 -M LV5048 -I
pi@raspberrypi:~ $ sudo mpp-solar -c QPIGS2 -M LV5048 -I INFO:MPP-Solar:command QPIGS2 INFO:MPP-Solar:Serial device used: /dev/ttyUSB0, baud rate: 2400 INFO:MPP-Solar:Loading commands for inverter model: LV5048 INFO:MPP-Solar:... command F loaded for inverter model: LV5048 INFO:MPP-Solar:... command MCHGC loaded for inverter model: LV5048 INFO:MPP-Solar:... command MNCHGC loaded for inverter model: LV5048 INFO:MPP-Solar:... command MUCHGC loaded for inverter model: LV5048 INFO:MPP-Solar:... command PBCV loaded for inverter model: LV5048 INFO:MPP-Solar:... command PBDV loaded for inverter model: LV5048 INFO:MPP-Solar:... command PBFT loaded for inverter model: LV5048 INFO:MPP-Solar:... command PBT loaded for inverter model: LV5048 INFO:MPP-Solar:... command PCP loaded for inverter model: LV5048 INFO:MPP-Solar:... command PCVV loaded for inverter model: LV5048 INFO:MPP-Solar:... command PEPD loaded for inverter model: LV5048 INFO:MPP-Solar:... command PF loaded for inverter model: LV5048 INFO:MPP-Solar:... command PGR loaded for inverter model: LV5048 INFO:MPP-Solar:... command POP loaded for inverter model: LV5048 INFO:MPP-Solar:... command POPM loaded for inverter model: LV5048 INFO:MPP-Solar:... command PPCP loaded for inverter model: LV5048 INFO:MPP-Solar:... command PPVOKC loaded for inverter model: LV5048 INFO:MPP-Solar:... command PSDV loaded for inverter model: LV5048 INFO:MPP-Solar:... command PSPB loaded for inverter model: LV5048 INFO:MPP-Solar:... command Q1 loaded for inverter model: LV5048 INFO:MPP-Solar:... command QBOOT loaded for inverter model: LV5048 INFO:MPP-Solar:... command QDI loaded for inverter model: LV5048 INFO:MPP-Solar:... command QFLAG loaded for inverter model: LV5048 INFO:MPP-Solar:... command QID loaded for inverter model: LV5048 INFO:MPP-Solar:... command QMCHGCR loaded for inverter model: LV5048 INFO:MPP-Solar:... command QMOD loaded for inverter model: LV5048 INFO:MPP-Solar:... command QMUCHGCR loaded for inverter model: LV5048 INFO:MPP-Solar:... command QOPM loaded for inverter model: LV5048 INFO:MPP-Solar:... command QP2GSn loaded for inverter model: LV5048 INFO:MPP-Solar:... command QPGSn loaded for inverter model: LV5048 INFO:MPP-Solar:... command QPI loaded for inverter model: LV5048 INFO:MPP-Solar:... command QPIGS loaded for inverter model: LV5048 INFO:MPP-Solar:... command QPIGS2 loaded for inverter model: LV5048 INFO:MPP-Solar:... command QPIRI loaded for inverter model: LV5048 INFO:MPP-Solar:... command QPIWS loaded for inverter model: LV5048 INFO:MPP-Solar:... command QVFW loaded for inverter model: LV5048 INFO:MPP-Solar:... command QVFW2 loaded for inverter model: LV5048 INFO:MPP-Solar:SERIAL connection: executing QPIGS2 General Status Parameters inquiry -- queries the value of various metrics from the Inverter
is_l2_ac_charging_on 0 True - 1/False - 0 is_l2_line_not_ok 0 True - 1/False - 0 is_l2_scc_charging_on 0 True - 1/False - 0 is_l2_scc_ok 0 True - 1/False - 0 is_load_on 1 True - 1/False - 0 l2_ac_input_frequency 60.0 Hz l2_ac_input_voltage 123.8 V l2_ac_output_active_power 0492 W l2_ac_output_apparent_power 0539 VA l2_ac_output_frequency 60.0 Hz l2_ac_output_load 021 % l2_ac_output_voltage 119.8 V l2_battery_voltage 52.20 V pv2_battery_charging_current 0000 A pv2_input_voltage 000.0 V reserved 1 True - 1/False - 0 pi@raspberrypi:~ $
Interesting - so the only ones that dont seem to work are the parallel commands
can you run mpp-solar -c QPIRI -M LV5048
for me please
Also, what is the box below the 3 inverters?
pi@raspberrypi:~ $ sudo mpp-solar -c QPIRI -M LV5048
WARNING:MPP-Solar:Serial read error: list index out of range
Traceback (most recent call last):
File "/usr/local/bin/mpp-solar", line 11, in
Box houses DC breakers for each inverter and generic battery monitor.
Bummer, ok try sudo mpp-solar -c QPIRI -M LV5048 -R
pi@raspberrypi:~ $ sudo mpp-solar -c QPIRI -M LV5048 -R WARNING:MPP-Solar:Serial read error: list index out of range (120.0 20.8 120.0 60.0 20.8 2500 2500 48.0 47.0 43.0 56.1 56.1 2 40 060 0 0 0 9 01 0 6 55.0 0 1 000��
OK, so fixed the above error - but I just can't figure out why any command with the parallel ID fails to work - it looks like the command isn't recognized but it is the command as per the documentation.
Thanks . I will reinstall in the morning and try again. I really appreciate your help.
Sent from Mailhttps://go.microsoft.com/fwlink/?LinkId=550986 for Windows 10
From: jblancemailto:notifications@github.com Sent: Friday, March 27, 2020 9:33 PM To: jblance/mpp-solarmailto:mpp-solar@noreply.github.com Cc: Dalibor Majksnermailto:dalibor@jcwon.com; Authormailto:author@noreply.github.com Subject: Re: [jblance/mpp-solar] Adding commands for LV5048. (#11)
OK, so fixed the above error - but I just can't figure out why any command with the parallel ID fails to work - it looks like the command isn't recognized but it is the command as per the documentation.
— You are receiving this because you authored the thread. Reply to this email directly, view it on GitHubhttps://github.com/jblance/mpp-solar/issues/11#issuecomment-605375516, or unsubscribehttps://github.com/notifications/unsubscribe-auth/AO4DWSXFGT7AZ36ZQFIZSULRJVHWTANCNFSM4LUD7OBA.
QPIGS Inverter general status parameters inquiry for Line 1 of one inverter. It works. QPIGS2 Inverter general status parameters inquiry for Line 2 of one inverter. It works.
With these commands above I see all of the information from one inverter. Since L1 and L2 are 180 deg out that gives 240 volts across them. Full phase. L1 to N = 120 Volts L2 to N = 120 Volts for split phase.
For this to work, I think each inverter will need it's own connection to Raspberry Pi. USB to Serial. Unless you can add lines for USB connection. I do not think that we know the code to pick up all of the information that is floating around through parallel cables between inverters.
And in that case QPGSn and QP2GSn will work. I will see if MicroCenter has any USB to serial cabels today.
Bought 2 more USB to serial connectors. Looking better. Shows no errors but no information comes back for QP2GSn QPGSn
pi@raspberrypi:~ $ sudo mpp-solar -c QP2GS0 -M LV5048
pi@raspberrypi:~ $ sudo mpp-solar -c QP2GS1 -M LV5048
pi@raspberrypi:~ $ sudo mpp-solar -c QPGS1 -M LV5048
pi@raspberrypi:~ $ sudo mpp-solar -c QPGS2 -M LV5048
pi@raspberrypi:~ $ sudo mpp-solar -c QPIGS -M LV5048
battery_capacity 100 %
battery_charging_current 000 A
battery_discharge_current 00000 A
battery_voltage 56.20 V
battery_voltage_from_scc 00.00 V
bus_voltage 225 V
inverter_heat_sink_temperature 0036 Deg_C
is_battery_over 0 True - 1/False - 0
is_battery_under 0 True - 1/False - 0
is_l1_ac_charging_on 0 True - 1/False - 0
is_l1_line_not_ok 1 True - 1/False - 0
is_l1_scc_charging_on 0 True - 1/False - 0
is_l1_scc_ok 0 True - 1/False - 0
is_load_on 0 True - 1/False - 0
l1_ac_input_frequency 59.9 Hz
l1_ac_input_voltage 122.8 V
l1_ac_output_active_power 0392 W
l1_ac_output_apparent_power 0392 VA
l1_ac_output_frequency 59.9 Hz
l1_ac_output_load 015 %
l1_ac_output_voltage 122.8 V
pv_input_current_for_battery 0000 A
pv_input_voltage 000.0 V
unknown_value_in_response 110
pi@raspberrypi:~ $ sudo mpp-solar -c QPIGS2 -M LV5048
is_l2_ac_charging_on 0 True - 1/False - 0
is_l2_line_not_ok 0 True - 1/False - 0
is_l2_scc_charging_on 0 True - 1/False - 0
is_l2_scc_ok 0 True - 1/False - 0
is_load_on 1 True - 1/False - 0
l2_ac_input_frequency 59.9 Hz
l2_ac_input_voltage 123.5 V
l2_ac_output_active_power 0094 W
l2_ac_output_apparent_power 0111 VA
l2_ac_output_frequency 59.9 Hz
l2_ac_output_load 004 %
l2_ac_output_voltage 123.5 V
l2_battery_voltage 56.20 V
pv2_battery_charging_current 0000 A
pv2_input_voltage 000.0 V
reserved 0 True - 1/False - 0
Great that you have a solution. Just strange that the commands dont work as per the docs. My parallel 4048s work with QPGS0 and 1 showing the data from the 2 inverters while only connected to one of them.
Well. Now when I type pi@raspberrypi:~ $ sudo mpp-solar -c QP2GS0 -M LV5048 it returns as this
pi@raspberrypi:~ $ sudo mpp-solar -c QP2GS0 -M LV5048 pi@raspberrypi:~ $
It does not give error or anything else.
Sorry, yes i was cleaning up some of the log messages
I have added a bit more information to the response if the command fails now - e.g.
mpp-solar -c QPIRI -d TEST -M LV5048
error Invalid response
response (NAKss
Will test it out. Thank you.
Very glad to see you guys working together on a solution to this. I have an LV5048 and have been struggling for a couple of months trying to get a data logged in a useful format with "solar-sis" for the 4048. Your efforts are very much appreciated!
Ok. I see what you mean. Well. It is another wall barrier. I need to put my hard thinking hat on.
ok, so the java code shows the command is QPGS0
- also it has some indication that it tries multiple times...
e.g. the below tries 3 times from P41ComUSBProcessor.java
for (try_i = 0, try_i = 0; try_i < 3; ++try_i) {
ret = handler.excuteCommand("QPGS0", true);
if (!ret.equals("(NAK")) {
break;
}
}
Maybe try bruting it? Can you try the below:
for x in 1 2 3 4 5; do echo $x; sudo mpp-solar -c QP2GS0 -M LV5048; done
With my thinking hat on........ can it be done via USB connection? Three USB cables = 3 devices There for mpp-solar -c QPIGS or QPIGS2 -d /dev/hidraw0 or 1 or 2
How do I try that command? Maybe try bruting it? Can you try the below: for x in 1 2 3 4 5; do echo $x; sudo mpp-solar -c QP2GS0 -M LV5048; done
pi@raspberrypi:~ $ echo $1; sudo mpp-solar -c QP2GS0 -M LV5048; done bash: syntax error near unexpected token `done' pi@raspberrypi:~ $ echo $1; sudo mpp-solar -c QP2GS0 -M LV5048;
error Invalid response
response (NAKss
pi@raspberrypi:~ $ echo $1; sudo mpp-solar -c QP2GS0 -M LV5048
error Invalid response
response (NAKss
pi@raspberrypi:~ $
LV5048 5KW protocol-20190222 for customer.pdf Hello,
Thank you for your help last week. I was in touch with MPP Solar and they provided communication protocol for LV5048. See attached. Is there way to integrate some of these commands with what you have written so far?