issues
search
jbuehl
/
solaredge
SolarEdge inverter logging data capture
GNU General Public License v3.0
288
stars
60
forks
source link
issues
Newest
Newest
Most commented
Recently updated
Oldest
Least commented
Least recently updated
RS485 battery interface question
#190
jutshanahan
opened
5 months ago
0
Bump pycryptodome from 3.16.0 to 3.19.1
#189
dependabot[bot]
opened
6 months ago
0
Disable DC Safemode?
#188
eggehad
closed
9 months ago
1
Issue painfully slow data extraction using RS485 solved
#187
eriksl
opened
10 months ago
1
ethernet active mode: failed to parse message
#186
fredericve
opened
10 months ago
2
Exception while reading data, getting Solaredge key
#185
fozed1
opened
10 months ago
3
Exception while reading data
#184
fozed1
closed
10 months ago
0
Maybe want to help dissecting the 0x3c2 message
#183
eriksl
opened
10 months ago
0
semonitor mis-identifies the serial numbers on some of my optimizers
#182
eggehad
closed
10 months ago
3
run CI on forks
#181
ericbuehl
closed
1 year ago
0
Dockerise semonitor
#180
oliv3r
opened
1 year ago
13
Deprecation and sanity improvements
#179
oliv3r
closed
1 year ago
0
Remote serial converter
#178
eriksl
closed
10 months ago
9
Just a little help RS485 please
#177
eriksl
closed
10 months ago
4
Where to insert key
#176
fozed1
closed
10 months ago
0
Can't get useful data from SE10000H via RS-485, Unknown Function
#175
cschuhen
closed
1 year ago
3
test
#173
ericbuehl
closed
1 year ago
0
use github actions, deprecate circleci
#172
ericbuehl
closed
1 year ago
0
Initial commit to add the se2influx.py utility.
#171
eschwim
closed
1 year ago
0
Semonitor has stopped producing any output
#170
Millox
closed
1 year ago
1
"TypeError: ord() expected string of length 1, but int found" in network.py
#169
InFerYes
opened
1 year ago
0
Add support for S440 optimizers
#168
hberntsen
closed
2 years ago
1
Multiple Connections
#167
gamblor999
opened
2 years ago
2
semonitor.py does not always produce valid JSON
#166
ocaj-nl
opened
2 years ago
0
FiX key extraction from RS485 interface
#165
BenCastricum
closed
2 years ago
0
Solaredge webscrape - PO data without inverter configuration
#164
dragoshenron
opened
2 years ago
0
Can we access module (optimizer) data totally remotely?
#163
inckagan
closed
2 years ago
4
Exception: timestamp out of range for platform time_t
#162
ocaj-nl
closed
2 years ago
4
Setting battery charge/discharge profiles
#161
nerfherder
opened
3 years ago
0
First time serial
#160
Kirstabro
opened
3 years ago
2
Time set of the converter by RS485-USB-adapter without fully started OS?
#159
ethpi
opened
3 years ago
1
Python3 ?
#158
Mike4U
closed
3 years ago
2
No data on RS485 passive
#157
dennisfisch
opened
3 years ago
7
Could firmware update of inverter SE4K conflict with old semonitor.py via RS485?
#156
ethpi
closed
2 years ago
2
lg battery modbus registers description or rs485 log
#155
math322
opened
3 years ago
1
semonitor won't open serial port if symlink
#154
Millox
closed
1 year ago
4
Data length is too big for the message
#153
JustApu
opened
4 years ago
1
SolarEdge
#152
manne71
closed
4 years ago
0
Battery Data always Zero
#151
felixmartens
opened
4 years ago
0
Optimizer data via modbus
#150
marcpuca
opened
4 years ago
7
Has solaredge switched to SSL?
#149
hydrael
opened
4 years ago
8
State of (active) network mode
#148
michelwilson
opened
4 years ago
3
RS485 key retrieval value zero
#147
fgnn
opened
4 years ago
4
semonitor.py Output Files
#146
Llibyddap
closed
4 years ago
3
Fix readMsg in doCommand
#145
jpnp
closed
4 years ago
0
SMI safety monitoring interface
#144
gruenst
opened
4 years ago
0
Optimizer inputC parameter - integer vs float
#143
dragoshenron
opened
4 years ago
0
Solution working with latest model (without display) and latest firmware
#142
pschelling
opened
4 years ago
19
Waiting for DNS message: timed out
#141
Llibyddap
closed
4 years ago
3
RS485-1 and RS485-E configuration with LG battery
#140
antoniolobefaro
opened
4 years ago
2
Next