Open moradza opened 5 years ago
Hi,
Please send me your input files (julien.devemy(at)uca.fr), I'll try to take a look.
Bye, Julien
Hi,
Please find the attachments of the input files, I got the force field for ions from https://pubs.acs.org/doi/10.1021/ct900576a. I did one simulation in the confinement and I noticed drude particles get absorbed by K+ ions, and then suddenly jump away.
Thanks, Alireza
From: Julien Devémy [mailto:notifications@github.com] Sent: Friday, November 8, 2019 4:19 AM To: jdevemy/lammps-drude Cc: Moradzadeh, Alireza; Author Subject: Re: [jdevemy/lammps-drude] Question About Ions with SWM4-NDP (#2)
Hi,
Please send me your input files (julien.devemy(at)uca.fr), I'll try to take a look.
Bye, Julien
— You are receiving this because you authored the thread. Reply to this email directly, view it on GitHubhttps://github.com/jdevemy/lammps-drude/issues/2?email_source=notifications&email_token=ADSPOQ6YSAJTOMBKPXJ2CPDQSU4IJA5CNFSM4JIACD62YY3PNVWWK3TUL52HS4DFVREXG43VMVBW63LNMVXHJKTDN5WW2ZLOORPWSZGOEDPY47Q#issuecomment-551521918, or unsubscribehttps://github.com/notifications/unsubscribe-auth/ADSPOQ7QE6KPHX6L7W6UOSLQSU4IJANCNFSM4JIACD6Q.
Hi, I simulate NaCl with water of SWM4-NDP and also encountered this problem. How did you solve it. Please give me some suggestion. Thanks, Chenxia
Hi, Strong H-bonds or small, densely-charged ions (Li+, Na+) can lead to instabilities in the induced dipoles. We added a short-range damping function to charge-induce dipole interactions in order to remedy this. It is implemented in lammps (pair/coul/tt). You could add it to the interactions between Na+ and the drude dipole on Ow atoms. Please check this publication 10.26434/chemrxiv.12999524.v3 Let us know if this helps. Agilio
Hi,
Thanks for the great wor. I am trying to simulate a pair of KCl ions solvated in the water. And, I am using drude polarizable model for all the entities of my system. I am using a very similar input file as the one used in the swm4-ndp example. However, my simulation crashes after 5000-40,000 steps. Can you suggest what can be wrong in my simulation?
Do you have any example for similar system to share it? I highly appreciate your help.
Thanks, Alireza