The Shelly Plus 1PM with the add-on device placed on it is able to handle 5x temperature-sensors… In Homey Pro the sensors are named in the follow way:

Temperature-sensor 1 Temperature-sensor 2 Temperature-sensor 3 Temperature-sensor Temperature-sensor Instead of numbering up to 4 and 5, it gives a basic name without a number… Ok, it is possible to use it in a flow, but it is always the big question wich one is 4 or 5… Just try it a few times and you find the correct temp.device. Would it be possible to fix this issue in a next update? Even more great would be, when the defined sensorname from Shelly-cloud/device would be there instead of a number! Thanks anyway for reading this!

Best regards,

Mark Kobes

jghaanstra commented 1 year ago

Wil fix it with the next release. That may take a while though as I'll be on holiday for the next weeks.

jghaanstra commented 1 year ago

Should be fixed with release 3.21.1, please test and confirm.

MarkKobes commented 1 year ago

Thank you! Problem solved!

Verzonden vanaf Outlook voor Androidhttps://aka.ms/AAb9ysg


From: Jelger Haanstra @.> Sent: Tuesday, August 1, 2023 8:43:56 PM To: jghaanstra/cloud.shelly @.> Cc: Mark Kobes @.>; Author @.> Subject: Re: [jghaanstra/cloud.shelly] Shelly Plus 1Pm with addon with more than 3 temp.sensors (Issue #193)

Should be fixed with release 3.21.1, please test and confirm.

— Reply to this email directly, view it on GitHubhttps://github.com/jghaanstra/cloud.shelly/issues/193#issuecomment-1660887100, or unsubscribehttps://github.com/notifications/unsubscribe-auth/AYS6OVOKG2PGIIVQXB6VX73XTFE6ZANCNFSM6AAAAAA27LW3UY. You are receiving this because you authored the thread.Message ID: @.***>