Genmon Use of 003a instead of 05f4 and 05f5 for Load Current Values #403

Closed sefs85 closed 4 years ago

sefs85 commented 4 years ago

Use the template below if you have an issue or want to report a bug. If you have a question or a feature request you can ignore the questions below.

NOTE: If you are having issues with your serial connection, please read this page before posting:

https://github.com/jgyates/genmon/wiki/3.6---Serial-Troubleshooting

If you are having other issues, please see the following page:

https://github.com/jgyates/genmon/wiki/3.5---General-Troubleshooting

If you need to send you logs and registers to the developer, if you email is setup and working properly you can click send your logs on the About page in the web interface.

Expected Behavior

Genmon should read the CT1 and CT2 registers to determine load current. 05f4 and 05f5

Actual Behavior

Gemon is reading 003a, which I believe is actually the position of the stepper motor controlling the throttle. This is why it has a significant value when you are running no-load, but also appears to be closely related when loads are put on or taken off of the generator.

The best solution would be if we could have both L1 and L2 voltages (~120V), however, since the generator only reads L1-L2 voltage (~240V), the closest calculation that should be done is Approximate_240V_Load = (CT1+CT2)/2. This would then properly calculate into the kW Power.

Steps to Reproduce (including precondition)

Anytime the generator is running.

Screenshot or Pictures relating to the problem (if possible)

{Please write here}

Your Environment

grsthegreat commented 4 years ago

Also, i doubt it matters which side of breaker you mount ct's to. My clamp on meter reads same Regardless. The only place dealer has to mount to is gen side during construction. The manufacturer does not have to follow NEC wire size. Heck, neither do utilities. Look at the size wires dropping off of power poles that hook up to the ridiculous large size wires we have to run.

On Tue, Aug 11, 2020, 1:36 PM Affordable Electric grsaec1@gmail.com wrote:

22kw arnt supposed to have them, only the 20 and less. Weird

On Tue, Aug 11, 2020, 1:27 PM jwtaylor310 notifications@github.com wrote:

Hi, lilux;

My generator is a 22 KW Evo2. That's why I was surprised to find that it has CT's factory installed.

Thanks for the location and wire rating info.

— You are receiving this because you were mentioned. Reply to this email directly, view it on GitHub https://github.com/jgyates/genmon/issues/403#issuecomment-672261988, or unsubscribe https://github.com/notifications/unsubscribe-auth/AMBLZMCAG66GLX5H4PMT5ILSAGSS3ANCNFSM4OA6FIKA .

grsthegreat commented 4 years ago

Power is out......cts working great. I can now see what turning on oven snd ac unit do to my power supply.

chia9876 commented 3 years ago

22kw arnt supposed to have them, only the 20 and less. Weird My 22 kw doesn't have them, and the last 22kw i installed a few months back did not have them.

Hello Everyone, I'm new here and I'm in the middle of installing my 24kw air cooled gen and was planning on putting in the current transformers when I also noticed that I also have them factory installed. The 24kw just came out so maybe Generac is installing them on all gens now?!? 20201121_134820 20201121_135013~01 20201121_134622~01_1

liltux commented 3 years ago

Yes, I believe on 2019/2020 and newer units all have CTs. Safe to get if your unit is 2017 and older 22KW, you do not have CTs.