Open supermas opened 1 year ago
I have the exact same problem :/
did you find out how?
No answers yet but I have a horrible feeling we're going to have to do it from the Data Logger Dongle itself.
see https://github.com/johanmeijer/grott/issues/79
just try and try again
Have you checked that the container is reachable at your IP? i.e. can you connect to 192.168.1.226 on port 5279? If not, you need to fix your Docker forwarding, otherwise no amount of fiddling with the data logger settings will help.
If server IP is being set to the grott address and it does not reach grott then it will not be possible to communicate with the inverter from the growatt site (and no statics will be shown anymore).
If you still are able to set or read things then probably the address in not set (or grott is doing its thing, look with docker logs command).
Good point.
The last lines of the Docker grottrpi say:
Grott proxy mode started Hostname : 33c95e2349a3 IP : 172.17.0.2 , port : 5279
Do I assume the IP listed is the one I should be connecting to?
If so, why is it not in my network range, 192.168..?
It will be your network range 192.168... the 172.17 is the internal docker IP address.
If you specified the docker port at 5279 (-p 5279:5279) then grott address will be 192.168.x.y:5279.
Ah, okay.
At this point I should state that I am a Docker newby and this was my first project.
So after running "docker run ledidobe/grottrpi" and seeing all the config go past, the interface stays open (no prompt)
I have to Ctrl C to get back to prompt.
Is that expected behaviour?
I installed the image and just ran it.
The instructions seemed to suggest that defaults would kick in and all would be well.
Is the Growatt Data Logger clever enough to check it gets a valid response from the IP before it lets you switch to it?
I do not think so. But have never tried it....
If you have started the docker container you can look in the log with docker logs command (docker logs grott). You can see if something is being sent via grott.
You can also try to go grott via a browser page by 192.168.x.y:5279. You will see nothing in the browser but should see something in the grott log.
Okay a step further..
Re-ran docker with command line params: docker run -d -p 5279:5279 --restart on-failure -e gmqttip="192.168.1.226" ledidobe/grott
prompt came back.
Checked logs - looking good.
pointed browser at 192.168.1.226:5297 - spinning..
Re-checked logs and new message: Growatt packet received: etc..
Now if I could just get my Data Logger IP to change..
Otherwise you have to reset your datalogger en start configuring it again.
@supermas is this one solved?
I've put this on the back burner for now.
Thanks for all your help getting this far.
I ran into the same problem, but just resolved it after an hour or so's trial and error, this is with a Shine Wifi-S
What didn't work: editing the datalogger configuration via the web UI and changing the IP. The 'Successful' message is a lie.
What did work: Using the ShinePhone app, click the + in the top right hand corner and list dataloggers.
Go to 'Datalogger configuration'
Put the Shine Wifi-S into AP mode, this requires physically pressing the reset switch on the dongle itself.
Once in AP mode and connected to the hotspot (pw: 12345678), go to advanced settings - change the server IP there. The interface for this is completely different even though the setting is theoretically the same. You can also change the update frequency here if you want it lower than the standard 5 minutes.
Exit AP mode.
After this I started getting output from grott/mqtt.
I ran into the same problem, but just resolved it after an hour or so's trial and error, this is with a Shine Wifi-S
What didn't work: editing the datalogger configuration via the web UI and changing the IP. The 'Successful' message is a lie.
What did work: Using the ShinePhone app, click the + in the top right hand corner and list dataloggers.
Go to 'Datalogger configuration'
Put the Shine Wifi-S into AP mode, this requires physically pressing the reset switch on the dongle itself.
Once in AP mode and connected to the hotspot (pw: 12345678), go to advanced settings - change the server IP there. The interface for this is completely different even though the setting is theoretically the same. You can also change the update frequency here if you want it lower than the standard 5 minutes.
Exit AP mode.
After this I started getting output from grott/mqtt.
Change it to what exactly? I understand the 172.x.x.x IP is not the correct one and it should be 192.168.x.y. But how do I find what x and y it is using?
And going to advanced settings after connecting to the hotspot happens in the app? Of through a web config?
I am running Docker on a Raspberry Pi Zero following your instructions.
The Raspberry Pi IP address is 192.168.1.226
I run: docker run ledidobe/grottrpi
and I get this output: Grott Growatt logging monitor : 2.6.1g
Grott Command line parameters processed: verbose: True config file: grott.ini output file: <_io.TextIOWrapper name='' mode='w' encoding='UTF-8'>
nomqtt: False
inverterid: automatic
pvoutput: False
blockcmd: False
noipf: False
Grott process configuration file
Grott process environmental variables
Grott override settings if set in commandline
Grott process json layout files t0060104sph.json
Grott layout records loaded T02NNNN : {'decrypt': {'value': 'False'}, 'pvserial': {'value': 36, 'length': 10, 'type': 'text', 'divide': 10}, 'date': {'value': 56, 'divide': 10}, 'recortype1': {'value': 70, 'length': 2, 'type': 'num', 'incl': 'no'}, 'recortype2': {'value': 74, 'length': 2, 'type': 'num', 'incl': 'no'}, 'pvstatus': {'value': 78, 'length': 2, 'type': 'num'}, 'pvpowerin': {'value': 82, 'length': 4, 'type': 'num', 'divide': 10}, 'pv1voltage': {'value': 90, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1current': {'value': 94, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1watt': {'value': 98, 'length': 4, 'type': 'num', 'divide': 10}, 'pv2voltage': {'value': 106, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2current': {'value': 110, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2watt': {'value': 114, 'length': 4, 'type': 'num', 'divide': 10}, 'pvpowerout': {'value': 122, 'length': 4, 'type': 'num', 'divide': 10}, 'pvfrequentie': {'value': 130, 'length': 2, 'type': 'num', 'divide': 100}, 'pvgridvoltage': {'value': 134, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent': {'value': 138, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower': {'value': 142, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage2': {'value': 150, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent2': {'value': 154, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower2': {'value': 158, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage3': {'value': 166, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent3': {'value': 170, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower3': {'value': 174, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytoday': {'value': 182, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytotal': {'value': 190, 'length': 4, 'type': 'num', 'divide': 10}, 'totworktime': {'value': 198, 'length': 4, 'type': 'num', 'divide': 7200}, 'pvtemperature': {'value': 206, 'length': 2, 'type': 'num', 'divide': 10}, 'isof': {'value': 210, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'gfcif': {'value': 214, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'dcif': {'value': 218, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'vpvfault': {'value': 222, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'vacfault': {'value': 226, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'facfault': {'value': 230, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'tmpfault': {'value': 234, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'faultcode': {'value': 238, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'pvipmtemperature': {'value': 242, 'length': 2, 'type': 'num', 'divide': 10}, 'pbusvolt': {'value': 246, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'nbusvolt': {'value': 250, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'epv1today': {'value': 278, 'length': 4, 'type': 'num', 'divide': 10}, 'epv1total': {'value': 286, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2today': {'value': 294, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2total': {'value': 302, 'length': 4, 'type': 'num', 'divide': 10}, 'epvtotal': {'value': 310, 'length': 4, 'type': 'num', 'divide': 10}, 'rac': {'value': 318, 'length': 4, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'eractoday': {'value': 326, 'length': 4, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'eractotal': {'value': 334, 'length': 4, 'type': 'num', 'divide': 1, 'incl': 'no'}} T05NNNN : {'decrypt': {'value': 'True'}, 'pvserial': {'value': 36, 'length': 10, 'type': 'text', 'divide': 10}, 'date': {'value': 56, 'divide': 10}, 'recortype1': {'value': 70, 'length': 2, 'type': 'num', 'incl': 'no'}, 'recortype2': {'value': 74, 'length': 2, 'type': 'num', 'incl': 'no'}, 'pvstatus': {'value': 78, 'length': 2, 'type': 'num'}, 'pvpowerin': {'value': 82, 'length': 4, 'type': 'num', 'divide': 10}, 'pv1voltage': {'value': 90, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1current': {'value': 94, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1watt': {'value': 98, 'length': 4, 'type': 'num', 'divide': 10}, 'pv2voltage': {'value': 106, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2current': {'value': 110, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2watt': {'value': 114, 'length': 4, 'type': 'num', 'divide': 10}, 'pvpowerout': {'value': 122, 'length': 4, 'type': 'numx', 'divide': 10}, 'pvfrequentie': {'value': 130, 'length': 2, 'type': 'num', 'divide': 100}, 'pvgridvoltage': {'value': 134, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent': {'value': 138, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower': {'value': 142, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage2': {'value': 150, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent2': {'value': 154, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower2': {'value': 158, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage3': {'value': 166, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent3': {'value': 170, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower3': {'value': 174, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytoday': {'value': 182, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytotal': {'value': 190, 'length': 4, 'type': 'num', 'divide': 10}, 'totworktime': {'value': 198, 'length': 4, 'type': 'num', 'divide': 7200}, 'pvtemperature': {'value': 206, 'length': 2, 'type': 'num', 'divide': 10}, 'isof': {'value': 210, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'gfcif': {'value': 214, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'dcif': {'value': 218, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'vpvfault': {'value': 222, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'vacfault': {'value': 226, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'facfault': {'value': 230, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'tmpfault': {'value': 234, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'faultcode': {'value': 238, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'pvipmtemperature': {'value': 242, 'length': 2, 'type': 'num', 'divide': 10}, 'pbusvolt': {'value': 246, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'nbusvolt': {'value': 250, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'epv1today': {'value': 278, 'length': 4, 'type': 'num', 'divide': 10}, 'epv1total': {'value': 286, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2today': {'value': 294, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2total': {'value': 302, 'length': 4, 'type': 'num', 'divide': 10}, 'epvtotal': {'value': 310, 'length': 4, 'type': 'num', 'divide': 10}, 'rac': {'value': 318, 'length': 4, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'eractoday': {'value': 326, 'length': 4, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'eractotal': {'value': 334, 'length': 4, 'type': 'num', 'divide': 1, 'incl': 'no'}} T06NNNN : {'decrypt': {'value': 'True'}, 'pvserial': {'value': 76, 'length': 10, 'type': 'text', 'divide': 10}, 'date': {'value': 136, 'divide': 10}, 'recortype1': {'value': 150, 'length': 2, 'type': 'num', 'incl': 'yes'}, 'recortype2': {'value': 154, 'length': 2, 'type': 'num', 'incl': 'yes '}, 'pvstatus': {'value': 158, 'length': 2, 'type': 'num'}, 'pvpowerin': {'value': 162, 'length': 4, 'type': 'num', 'divide': 10}, 'pv1voltage': {'value': 170, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1current': {'value': 174, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1watt': {'value': 178, 'length': 4, 'type': 'num', 'divide': 10}, 'pv2voltage': {'value': 186, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2current': {'value': 190, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2watt': {'value': 194, 'length': 4, 'type': 'num', 'divide': 10}, 'pvpowerout': {'value': 202, 'length': 4, 'type': 'numx', 'divide': 10}, 'pvfrequentie': {'value': 210, 'length': 2, 'type': 'num', 'divide': 100}, 'pvgridvoltage': {'value': 214, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent': {'value': 218, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower': {'value': 222, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage2': {'value': 230, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent2': {'value': 234, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower2': {'value': 238, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage3': {'value': 246, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent3': {'value': 250, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower3': {'value': 254, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytoday': {'value': 262, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytotal': {'value': 270, 'length': 4, 'type': 'num', 'divide': 10}, 'totworktime': {'value': 278, 'length': 4, 'type': 'num', 'divide': 7200}, 'pvtemperature': {'value': 286, 'length': 2, 'type': 'num', 'divide': 10}, 'isof': {'value': 290, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'gfcif': {'value': 294, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'dcif': {'value': 298, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'vpvfault': {'value': 302, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'vacfault': {'value': 306, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'facfault': {'value': 310, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'tmpfault': {'value': 314, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'faultcode': {'value': 318, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'pvipmtemperature': {'value': 322, 'length': 2, 'type': 'num', 'divide': 10}, 'pbusvolt': {'value': 326, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'nbusvolt': {'value': 330, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'epv1today': {'value': 358, 'length': 4, 'type': 'num', 'divide': 10}, 'epv1total': {'value': 366, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2today': {'value': 374, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2total': {'value': 382, 'length': 4, 'type': 'num', 'divide': 10}, 'epvtotal': {'value': 390, 'length': 4, 'type': 'num', 'divide': 10}} T05NNNNX : {'decrypt': {'value': 'True'}, 'pvserial': {'value': 36, 'length': 10, 'type': 'text', 'divide': 10}, 'date': {'value': 56, 'divide': 10}, 'recortype1': {'value': 70, 'length': 2, 'type': 'num', 'incl': 'no'}, 'recortype2': {'value': 74, 'length': 2, 'type': 'num', 'incl': 'no'}, 'pvstatus': {'value': 78, 'length': 2, 'type': 'num'}, 'pvpowerin': {'value': 82, 'length': 4, 'type': 'num', 'divide': 10}, 'pv1voltage': {'value': 90, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1current': {'value': 94, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1watt': {'value': 98, 'length': 4, 'type': 'num', 'divide': 10}, 'pv2voltage': {'value': 106, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2current': {'value': 110, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2watt': {'value': 114, 'length': 4, 'type': 'num', 'divide': 10}, 'pvpowerout': {'value': 170, 'length': 4, 'type': 'numx', 'divide': 10}, 'pvfrequentie': {'value': 178, 'length': 2, 'type': 'num', 'divide': 100}, 'pvgridvoltage': {'value': 182, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent': {'value': 186, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower': {'value': 190, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage2': {'value': 198, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent2': {'value': 202, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower2': {'value': 206, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage3': {'value': 214, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent3': {'value': 218, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower3': {'value': 222, 'length': 4, 'type': 'num', 'divide': 10}, 'totworktime': {'value': 266, 'length': 4, 'type': 'num', 'divide': 7200}, 'pvenergytoday': {'value': 274, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytotal': {'value': 282, 'length': 4, 'type': 'num', 'divide': 10}, 'epvtotal': {'value': 290, 'length': 4, 'type': 'num', 'divide': 10}, 'epv1today': {'value': 298, 'length': 4, 'type': 'num', 'divide': 10}, 'epv1total': {'value': 306, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2today': {'value': 314, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2total': {'value': 322, 'length': 4, 'type': 'num', 'divide': 10}, 'pvtemperature': {'value': 450, 'length': 2, 'type': 'num', 'divide': 10}, 'pvipmtemperature': {'value': 466, 'length': 2, 'type': 'num', 'divide': 10}, 'pbusvolt': {'value': 470, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'nbusvolt': {'value': 474, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}} T06NNNNX : {'decrypt': {'value': 'True'}, 'datalogserial': {'value': 16, 'length': 10, 'type': 'text', 'divide': 10, 'incl': 'no'}, 'pvserial': {'value': 76, 'length': 10, 'type': 'text', 'divide': 10}, 'date': {'value': 136, 'divide': 10}, 'recortype1': {'value': 150, 'length': 2, 'type': 'num', 'incl': 'yes'}, 'recortype2': {'value': 154, 'length': 2, 'type': 'num', 'incl': 'yes'}, 'pvstatus': {'value': 158, 'length': 2, 'type': 'num'}, 'pvpowerin': {'value': 162, 'length': 4, 'type': 'num', 'divide': 10}, 'pv1voltage': {'value': 170, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1current': {'value': 174, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1watt': {'value': 178, 'length': 4, 'type': 'num', 'divide': 10}, 'pv2voltage': {'value': 186, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2current': {'value': 190, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2watt': {'value': 194, 'length': 4, 'type': 'num', 'divide': 10}, 'pvpowerout': {'value': 250, 'length': 4, 'type': 'numx', 'divide': 10}, 'pvfrequentie': {'value': 258, 'length': 2, 'type': 'num', 'divide': 100}, 'pvgridvoltage': {'value': 262, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent': {'value': 266, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower': {'value': 270, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage2': {'value': 278, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent2': {'value': 282, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower2': {'value': 286, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage3': {'value': 294, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent3': {'value': 298, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower3': {'value': 302, 'length': 4, 'type': 'num', 'divide': 10}, 'totworktime': {'value': 346, 'length': 4, 'type': 'num', 'divide': 7200}, 'pvenergytoday': {'value': 354, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytotal': {'value': 362, 'length': 4, 'type': 'num', 'divide': 10}, 'epvtotal': {'value': 370, 'length': 4, 'type': 'num', 'divide': 10}, 'epv1today': {'value': 378, 'length': 4, 'type': 'num', 'divide': 10}, 'epv1total': {'value': 386, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2today': {'value': 394, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2total': {'value': 402, 'length': 4, 'type': 'num', 'divide': 10}, 'pvtemperature': {'value': 530, 'length': 2, 'type': 'num', 'divide': 10}, 'pvipmtemperature': {'value': 546, 'length': 2, 'type': 'num', 'divide': 10}, 'pbusvolt': {'value': 550, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'nbusvolt': {'value': 554, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}} T06NNNNXSPH : {'decrypt': {'value': 'True'}, 'pvserial': {'value': 76, 'length': 10, 'type': 'text', 'divide': 10}, 'date': {'value': 136, 'divide': 10}, 'recortype1': {'value': 150, 'length': 2, 'type': 'num', 'incl': 'no'}, 'recortype2': {'value': 154, 'length': 2, 'type': 'num', 'incl': 'no'}, 'pvstatus': {'value': 158, 'length': 2, 'type': 'num'}, 'pvpowerin': {'value': 162, 'length': 4, 'type': 'num', 'divide': 10}, 'pv1voltage': {'value': 170, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1current': {'value': 174, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1watt': {'value': 178, 'length': 4, 'type': 'num', 'divide': 10}, 'pv2voltage': {'value': 186, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2current': {'value': 190, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2watt': {'value': 194, 'length': 4, 'type': 'num', 'divide': 10}, 'pvpowerout': {'value': 298, 'length': 4, 'type': 'numx', 'divide': 10}, 'pvfrequentie': {'value': 306, 'length': 2, 'type': 'num', 'divide': 100}, 'pvgridvoltage': {'value': 310, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent': {'value': 314, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower': {'value': 318, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage2': {'value': 326, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent2': {'value': 330, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower2': {'value': 334, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage3': {'value': 342, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent3': {'value': 346, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower3': {'value': 350, 'length': 4, 'type': 'num', 'divide': 10}, 'totworktime': {'value': 386, 'length': 4, 'type': 'num', 'divide': 7200}, 'eactoday': {'value': 370, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytoday': {'value': 370, 'length': 4, 'type': 'num', 'divide': 10}, 'eactotal': {'value': 378, 'length': 4, 'type': 'num', 'divide': 10}, 'epvtotal': {'value': 522, 'length': 4, 'type': 'num', 'divide': 10}, 'epv1today': {'value': 394, 'length': 4, 'type': 'num', 'divide': 10}, 'epv1total': {'value': 402, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2today': {'value': 410, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2total': {'value': 418, 'length': 4, 'type': 'num', 'divide': 10}, 'pvtemperature': {'value': 530, 'length': 2, 'type': 'num', 'divide': 10}, 'pvipmtemperature': {'value': 534, 'length': 2, 'type': 'num', 'divide': 10}, 'pvboosttemp': {'value': 538, 'length': 2, 'type': 'num', 'divide': 10}, 'bat_dsp': {'value': 546, 'length': 2, 'type': 'num', 'divide': 10}, 'pbusvolt': {'value': 550, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, '#nbusvolt': {'value': 554, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, '#ipf': {'value': 558, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, '#realoppercent': {'value': 562, 'length': 2, 'type': 'num', 'divide': 100, 'incl': 'no'}, '#opfullwatt': {'value': 566, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, '#deratingmode': {'value': 574, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'eacharge_today': {'value': 606, 'length': 4, 'type': 'num', 'divide': 10}, 'eacharge_total': {'value': 614, 'length': 4, 'type': 'num', 'divide': 10}, 'batterytype': {'value': 634, 'length': 2, 'type': 'num', 'divide': 1}, 'uwsysworkmode': {'value': 666, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword0': {'value': 670, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword1': {'value': 674, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword2': {'value': 678, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword3': {'value': 682, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword4': {'value': 686, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword5': {'value': 690, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword6': {'value': 694, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword7': {'value': 698, 'length': 2, 'type': 'num', 'divide': 1}, 'pdischarge1': {'value': 702, 'length': 4, 'type': 'num', 'divide': 10}, 'p1charge1': {'value': 710, 'length': 4, 'type': 'num', 'divide': 10}, 'vbat': {'value': 718, 'length': 2, 'type': 'num', 'divide': 10}, 'SOC': {'value': 722, 'length': 2, 'type': 'num', 'divide': 100}, 'pactouserr': {'value': 726, 'length': 4, 'type': 'num', 'divide': 10}, '#pactousers': {'value': 734, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, '#pactousert': {'value': 742, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'pactousertot': {'value': 750, 'length': 4, 'type': 'num', 'divide': 10}, 'pactogridr': {'value': 758, 'length': 4, 'type': 'num', 'divide': 10}, '#pactogrids': {'value': 766, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, '#pactogridt': {'value': 774, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'pactogridtot': {'value': 782, 'length': 4, 'type': 'num', 'divide': 10}, 'plocaloadr': {'value': 790, 'length': 4, 'type': 'num', 'divide': 10}, '#plocaloads': {'value': 798, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, '#plocaloadt': {'value': 806, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'plocaloadtot': {'value': 814, 'length': 4, 'type': 'num', 'divide': 10}, '#ipm': {'value': 822, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, '#battemp': {'value': 826, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'spdspstatus': {'value': 830, 'length': 2, 'type': 'num', 'divide': 10}, 'spbusvolt': {'value': 834, 'length': 2, 'type': 'num', 'divide': 10}, 'etouser_tod': {'value': 842, 'length': 4, 'type': 'num', 'divide': 10}, 'etouser_tot': {'value': 850, 'length': 4, 'type': 'num', 'divide': 10}, 'etogrid_tod': {'value': 858, 'length': 4, 'type': 'num', 'divide': 10}, 'etogrid_tot': {'value': 866, 'length': 4, 'type': 'num', 'divide': 10}, 'edischarge1_tod': {'value': 874, 'length': 4, 'type': 'num', 'divide': 10}, 'edischarge1_tot': {'value': 882, 'length': 4, 'type': 'num', 'divide': 10}, 'eharge1_tod': {'value': 890, 'length': 4, 'type': 'num', 'divide': 10}, 'eharge1_tot': {'value': 898, 'length': 4, 'type': 'num', 'divide': 10}, 'elocalload_tod': {'value': 906, 'length': 4, 'type': 'num', 'divide': 10}, 'elocalload_tot': {'value': 914, 'length': 4, 'type': 'num', 'divide': 10}} T05NNNNSPF : {'decrypt': {'value': 'True'}, 'datalogserial': {'value': 16, 'length': 10, 'type': 'text', 'divide': 10, 'incl': 'no'}, 'pvserial': {'value': 36, 'length': 10, 'type': 'text', 'divide': 10}, 'date': {'value': 56, 'divide': 10}, 'recortype1': {'value': 70, 'length': 2, 'type': 'num', 'incl': 'no'}, 'recortype2': {'value': 74, 'length': 2, 'type': 'num', 'incl': 'no'}, 'pvstatus': {'value': 78, 'length': 2, 'type': 'num'}, 'vpv1': {'value': 82, 'length': 2, 'type': 'num', 'divide': 10}, 'vpv2': {'value': 86, 'length': 2, 'type': 'num', 'divide': 10}, 'ppv1': {'value': 90, 'length': 4, 'type': 'num', 'divide': 10}, 'ppv2': {'value': 98, 'length': 4, 'type': 'num', 'divide': 10}, 'buck1curr': {'value': 106, 'length': 2, 'type': 'num', 'divide': 10}, 'buck2curr': {'value': 110, 'length': 2, 'type': 'num', 'divide': 10}, 'op_watt': {'value': 114, 'length': 4, 'type': 'num', 'divide': 10}, 'pvpowerout': {'value': 114, 'length': 4, 'type': 'num', 'divide': 10}, 'op_va': {'value': 122, 'length': 4, 'type': 'num', 'divide': 10}, 'acchr_watt': {'value': 130, 'length': 4, 'type': 'num', 'divide': 10}, 'acchr_VA': {'value': 138, 'length': 4, 'type': 'num', 'divide': 10}, 'bat_Volt': {'value': 146, 'length': 2, 'type': 'num', 'divide': 100}, 'batterySoc': {'value': 150, 'length': 2, 'type': 'num', 'divide': 1}, 'bus_volt': {'value': 154, 'length': 2, 'type': 'num', 'divide': 10}, 'grid_volt': {'value': 158, 'length': 2, 'type': 'num', 'divide': 10}, 'line_freq': {'value': 162, 'length': 2, 'type': 'num', 'divide': 100}, 'outputvolt': {'value': 166, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridvoltage': {'value': 166, 'length': 2, 'type': 'num', 'divide': 10}, 'outputfreq': {'value': 170, 'length': 2, 'type': 'num', 'divide': 100}, 'invtemp': {'value': 178, 'length': 2, 'type': 'num', 'divide': 10}, 'dcdctemp': {'value': 182, 'length': 2, 'type': 'num', 'divide': 10}, 'loadpercent': {'value': 186, 'length': 2, 'type': 'num', 'divide': 10}, 'buck1_ntc': {'value': 206, 'length': 2, 'type': 'num', 'divide': 10}, 'buck2_ntc': {'value': 210, 'length': 2, 'type': 'num', 'divide': 10}, 'OP_Curr': {'value': 214, 'length': 2, 'type': 'num', 'divide': 10}, 'Inv_Curr': {'value': 218, 'length': 2, 'type': 'num', 'divide': 10}, 'AC_InWatt': {'value': 222, 'length': 4, 'type': 'num', 'divide': 10}, 'AC_InVA': {'value': 230, 'length': 4, 'type': 'num', 'divide': 10}, 'faultBit': {'value': 238, 'length': 2, 'type': 'num', 'divide': 1}, 'warningBit': {'value': 242, 'length': 2, 'type': 'num', 'divide': 1}, 'faultValue': {'value': 246, 'length': 2, 'type': 'num', 'divide': 1}, 'warningValue': {'value': 250, 'length': 2, 'type': 'num', 'divide': 1}, 'constantPowerOK': {'value': 266, 'length': 2, 'type': 'num', 'divide': 1}, 'epv1tod': {'value': 270, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'epv1tot': {'value': 278, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'epvToday': {'value': 278, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytoday': {'value': 278, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2tod': {'value': 286, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'epvTotal': {'value': 286, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytotal': {'value': 286, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2tot': {'value': 294, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'eacCharToday': {'value': 310, 'length': 4, 'type': 'num', 'divide': 10}, 'eacCharTotal': {'value': 318, 'length': 4, 'type': 'num', 'divide': 10}, 'ebatDischarToday': {'value': 326, 'length': 4, 'type': 'num', 'divide': 10}, 'ebatDischarTotal': {'value': 334, 'length': 4, 'type': 'num', 'divide': 10}, 'eacDischarToday': {'value': 342, 'length': 4, 'type': 'num', 'divide': 10}, 'eacDischarTotal': {'value': 350, 'length': 4, 'type': 'num', 'divide': 10}, 'ACCharCurr': {'value': 358, 'length': 2, 'type': 'num', 'divide': 10}, 'ACDischarWatt': {'value': 362, 'length': 4, 'type': 'num', 'divide': 10}, 'ACDischarVA': {'value': 370, 'length': 4, 'type': 'num', 'divide': 10}, 'BatDischarWatt': {'value': 378, 'length': 4, 'type': 'num', 'divide': 10}, 'BatDischarVA': {'value': 386, 'length': 4, 'type': 'num', 'divide': 10}, 'BatWatt': {'value': 394, 'length': 4, 'type': 'numx', 'divide': 10}} T06NNNNSPF : {'decrypt': {'value': 'True'}, 'datalogserial': {'value': 16, 'length': 10, 'type': 'text', 'divide': 10}, 'pvserial': {'value': 76, 'length': 10, 'type': 'text', 'divide': 10}, 'date': {'value': 136, 'divide': 10}, 'recortype1': {'value': 150, 'length': 2, 'type': 'num', 'incl': 'no'}, 'recortype2': {'value': 154, 'length': 2, 'type': 'num', 'incl': 'no'}, 'pvstatus': {'value': 158, 'length': 2, 'type': 'num'}, 'vpv1': {'value': 162, 'length': 2, 'type': 'num', 'divide': 10}, 'vpv2': {'value': 166, 'length': 2, 'type': 'num', 'divide': 10}, 'ppv1': {'value': 170, 'length': 4, 'type': 'num', 'divide': 10}, 'ppv2': {'value': 178, 'length': 4, 'type': 'num', 'divide': 10}, 'buck1curr': {'value': 186, 'length': 2, 'type': 'num', 'divide': 10}, 'buck2curr': {'value': 190, 'length': 2, 'type': 'num', 'divide': 10}, 'op_watt': {'value': 194, 'length': 4, 'type': 'num', 'divide': 10}, 'pvpowerout': {'value': 194, 'length': 4, 'type': 'num', 'divide': 10}, 'op_va': {'value': 204, 'length': 4, 'type': 'num', 'divide': 10}, 'acchr_watt': {'value': 210, 'length': 4, 'type': 'num', 'divide': 10}, 'acchr_VA': {'value': 218, 'length': 4, 'type': 'num', 'divide': 10}, 'bat_Volt': {'value': 226, 'length': 2, 'type': 'num', 'divide': 100}, 'batterySoc': {'value': 230, 'length': 2, 'type': 'num', 'divide': 1}, 'bus_volt': {'value': 234, 'length': 2, 'type': 'num', 'divide': 10}, 'grid_volt': {'value': 238, 'length': 2, 'type': 'num', 'divide': 10}, 'line_freq': {'value': 242, 'length': 2, 'type': 'num', 'divide': 100}, 'outputvolt': {'value': 246, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridvoltage': {'value': 246, 'length': 2, 'type': 'num', 'divide': 10}, 'outputfreq': {'value': 250, 'length': 2, 'type': 'num', 'divide': 100}, 'invtemp': {'value': 258, 'length': 2, 'type': 'num', 'divide': 10}, 'dcdctemp': {'value': 262, 'length': 2, 'type': 'num', 'divide': 10}, 'loadpercent': {'value': 266, 'length': 2, 'type': 'num', 'divide': 10}, 'buck1_ntc': {'value': 286, 'length': 2, 'type': 'num', 'divide': 10}, 'buck2_ntc': {'value': 290, 'length': 2, 'type': 'num', 'divide': 10}, 'OP_Curr': {'value': 294, 'length': 2, 'type': 'num', 'divide': 10}, 'Inv_Curr': {'value': 298, 'length': 2, 'type': 'num', 'divide': 10}, 'AC_InWatt': {'value': 302, 'length': 4, 'type': 'num', 'divide': 10}, 'AC_InVA': {'value': 310, 'length': 4, 'type': 'num', 'divide': 10}, 'faultBit': {'value': 318, 'length': 2, 'type': 'num', 'divide': 1}, 'warningBit': {'value': 322, 'length': 2, 'type': 'num', 'divide': 1}, 'faultValue': {'value': 326, 'length': 2, 'type': 'num', 'divide': 1}, 'warningValue': {'value': 330, 'length': 2, 'type': 'num', 'divide': 1}, 'constantPowerOK': {'value': 346, 'length': 2, 'type': 'num', 'divide': 1}, 'epvtoday': {'value': 358, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytoday': {'value': 358, 'length': 4, 'type': 'num', 'divide': 10}, 'epvtotal': {'value': 366, 'length': 4, 'type': 'num', 'divide': 10}, 'eacCharToday': {'value': 390, 'length': 4, 'type': 'num', 'divide': 10}, 'eacCharTotal': {'value': 398, 'length': 4, 'type': 'num', 'divide': 10}, 'ebatDischarToday': {'value': 406, 'length': 4, 'type': 'num', 'divide': 10}, 'ebatDischarTotal': {'value': 414, 'length': 4, 'type': 'num', 'divide': 10}, 'eacDischarToday': {'value': 422, 'length': 4, 'type': 'num', 'divide': 10}, 'eacDischarTotal': {'value': 430, 'length': 4, 'type': 'num', 'divide': 10}, 'ACCharCurr': {'value': 438, 'length': 2, 'type': 'num', 'divide': 10}, 'ACDischarWatt': {'value': 442, 'length': 4, 'type': 'num', 'divide': 10}, 'ACDischarVA': {'value': 450, 'length': 4, 'type': 'num', 'divide': 10}, 'BatDischarWatt': {'value': 458, 'length': 4, 'type': 'num', 'divide': 10}, 'BatDischarVA': {'value': 466, 'length': 4, 'type': 'num', 'divide': 10}, 'BatWatt': {'value': 474, 'length': 4, 'type': 'numx', 'divide': 10}} T06NNNNXTL3 : {'decrypt': {'value': 'True'}, 'datalogserial': {'value': 16, 'length': 10, 'type': 'text', 'divide': 10}, 'pvserial': {'value': 76, 'length': 10, 'type': 'text', 'divide': 10}, 'date': {'value': 136, 'divide': 10}, 'recortype1': {'value': 150, 'length': 2, 'type': 'num', 'incl': 'no'}, 'recortype2': {'value': 154, 'length': 2, 'type': 'num', 'incl': 'no'}, 'pvstatus': {'value': 158, 'length': 2, 'type': 'num'}, 'pvpowerin': {'value': 162, 'length': 4, 'type': 'num', 'divide': 10}, 'pv1voltage': {'value': 170, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1current': {'value': 174, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1watt': {'value': 178, 'length': 4, 'type': 'num', 'divide': 10}, 'pv2voltage': {'value': 186, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2current': {'value': 190, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2watt': {'value': 194, 'length': 4, 'type': 'num', 'divide': 10}, 'pv3voltage': {'value': 202, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'pv3current': {'value': 206, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'pv3watt': {'value': 210, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'pvpowerout': {'value': 298, 'length': 4, 'type': 'numx', 'divide': 10}, 'pvfrequentie': {'value': 306, 'length': 2, 'type': 'num', 'divide': 100}, 'pvgridvoltage': {'value': 310, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent': {'value': 314, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower': {'value': 318, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage2': {'value': 326, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent2': {'value': 330, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower2': {'value': 334, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage3': {'value': 342, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent3': {'value': 346, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower3': {'value': 350, 'length': 4, 'type': 'num', 'divide': 10}, 'Vac_RS': {'value': 358, 'length': 2, 'type': 'num', 'divide': 10}, 'Vac_ST': {'value': 362, 'length': 2, 'type': 'num', 'divide': 10}, 'Vac_TR': {'value': 366, 'length': 2, 'type': 'num', 'divide': 10}, 'pvenergytoday': {'value': 370, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytotal': {'value': 378, 'length': 4, 'type': 'num', 'divide': 10}, 'totworktime': {'value': 386, 'length': 4, 'type': 'num', 'divide': 7200}, 'epv1today': {'value': 394, 'length': 4, 'type': 'num', 'divide': 10}, 'epv1total': {'value': 402, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2today': {'value': 410, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2total': {'value': 418, 'length': 4, 'type': 'num', 'divide': 10}, 'epvtotal': {'value': 522, 'length': 4, 'type': 'num', 'divide': 10}, 'pvtemperature': {'value': 530, 'length': 2, 'type': 'num', 'divide': 10}, 'pvipmtemperature': {'value': 534, 'length': 2, 'type': 'num', 'divide': 10}, 'pvboottemperature': {'value': 538, 'length': 2, 'type': 'num', 'divide': 10}, 'temp4': {'value': 542, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'uwBatVolt_DSP': {'value': 546, 'length': 2, 'type': 'num', 'divide': 10}, 'pbusvolt': {'value': 550, 'length': 2, 'type': 'num', 'divide': 1}, 'nbusvolt': {'value': 554, 'length': 2, 'type': 'num', 'divide': 1}} T060120 : {'decrypt': {'value': 'True'}, 'datalogserial': {'value': 16, 'length': 10, 'type': 'text', 'divide': 10}, 'pvserial': {'value': 76, 'length': 10, 'type': 'text', 'divide': 10}, 'date': {'value': 136, 'divide': 10}, 'voltage_l1': {'value': 160, 'length': 4, 'type': 'num', 'divide': 10}, 'voltage_l2': {'value': 168, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'voltage_l3': {'value': 176, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'Current_l1': {'value': 184, 'length': 4, 'type': 'num', 'divide': 10}, 'Current_l2': {'value': 192, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'Current_l3': {'value': 200, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'act_power_l1': {'value': 208, 'length': 4, 'type': 'numx', 'divide': 10}, 'act_power_l2': {'value': 216, 'length': 4, 'type': 'numx', 'divide': 10, 'incl': 'no'}, 'act_power_l3': {'value': 224, 'length': 4, 'type': 'numx', 'divide': 10, 'incl': 'no'}, 'app_power_l1': {'value': 232, 'length': 4, 'type': 'numx', 'divide': 10}, 'app_power_l2': {'value': 240, 'length': 4, 'type': 'numx', 'divide': 10, 'incl': 'no'}, 'app_power_l3': {'value': 248, 'length': 4, 'type': 'numx', 'divide': 10, 'incl': 'no'}, 'react_power_l1': {'value': 256, 'length': 4, 'type': 'numx', 'divide': 10}, 'react_power_l2': {'value': 264, 'length': 4, 'type': 'numx', 'divide': 10, 'incl': 'no'}, 'react_power_l3': {'value': 272, 'length': 4, 'type': 'numx', 'divide': 10, 'incl': 'no'}, 'powerfactor_l1': {'value': 280, 'length': 4, 'type': 'numx', 'divide': 1000}, 'powerfactor_l2': {'value': 288, 'length': 4, 'type': 'numx', 'divide': 1000, 'incl': 'no'}, 'powerfactor_l3': {'value': 296, 'length': 4, 'type': 'numx', 'divide': 1000, 'incl': 'no'}, 'pos_rev_act_power': {'value': 304, 'length': 4, 'type': 'numx', 'divide': 10}, 'pos_act_power': {'value': 304, 'length': 4, 'type': 'numx', 'divide': 10, 'incl': 'no'}, 'rev_act_power': {'value': 304, 'length': 4, 'type': 'numx', 'divide': 10, 'incl': 'no'}, 'app_power': {'value': 312, 'length': 4, 'type': 'numx', 'divide': 10}, 'react_power': {'value': 320, 'length': 4, 'type': 'numx', 'divide': 10}, 'powerfactor': {'value': 328, 'length': 4, 'type': 'numx', 'divide': 1000}, 'frequency': {'value': 336, 'length': 4, 'type': 'num', 'divide': 10}, 'L1-2_voltage': {'value': 344, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'L2-3_voltage': {'value': 352, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'L3-1_voltage': {'value': 360, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'pos_act_energy': {'value': 368, 'length': 4, 'type': 'numx', 'divide': 10}, 'rev_act_energy': {'value': 376, 'length': 4, 'type': 'numx', 'divide': 10}, 'pos_act_energy_kvar': {'value': 384, 'length': 4, 'type': 'numx', 'divide': 10, 'incl': 'no'}, 'rev_act_energy_kvar': {'value': 392, 'length': 4, 'type': 'numx', 'divide': 10, 'incl': 'no'}, 'app_energy_kvar': {'value': 400, 'length': 4, 'type': 'numx', 'divide': 10, 'incl': 'no'}, 'act_energy_kwh': {'value': 408, 'length': 4, 'type': 'numx', 'divide': 10, 'incl': 'no'}, 'react_energy_kvar': {'value': 416, 'length': 4, 'type': 'numx', 'divide': 10, 'incl': 'no'}} T060104X : {'decrypt': {'value': 'True'}, 'pvserial': {'value': 76, 'length': 10, 'type': 'text', 'divide': 10}, 'date': {'value': 136, 'divide': 10}, '#recortype': {'value': 154, 'length': 2, 'type': 'num'}, 'pvstatus': {'value': 158, 'length': 2, 'type': 'num'}, 'pvpowerin': {'value': 162, 'length': 4, 'type': 'num', 'divide': 10}, 'pv1voltage': {'value': 170, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1current': {'value': 174, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1watt': {'value': 178, 'length': 4, 'type': 'num', 'divide': 10}, 'pv2voltage': {'value': 186, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2current': {'value': 190, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2watt': {'value': 194, 'length': 4, 'type': 'num', 'divide': 10}, 'pvpowerout': {'value': 298, 'length': 4, 'type': 'numx', 'divide': 10}, 'pvfrequentie': {'value': 306, 'length': 2, 'type': 'num', 'divide': 100}, 'pvgridvoltage': {'value': 310, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent': {'value': 314, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower': {'value': 318, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage2': {'value': 326, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent2': {'value': 330, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower2': {'value': 334, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage3': {'value': 342, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent3': {'value': 346, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower3': {'value': 350, 'length': 4, 'type': 'num', 'divide': 10}, 'totworktime': {'value': 386, 'length': 4, 'type': 'num', 'divide': 7200}, 'eactoday': {'value': 370, 'length': 4, 'type': 'num', 'divide': 10}, 'eactotal': {'value': 378, 'length': 4, 'type': 'num', 'divide': 10}, 'epvtotal': {'value': 522, 'length': 4, 'type': 'num', 'divide': 10}, 'epv1today': {'value': 394, 'length': 4, 'type': 'num', 'divide': 10}, 'epv1total': {'value': 402, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2today': {'value': 410, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2total': {'value': 418, 'length': 4, 'type': 'num', 'divide': 10}, 'pvtemperature': {'value': 530, 'length': 2, 'type': 'num', 'divide': 10}, 'pvipmtemperature': {'value': 534, 'length': 2, 'type': 'num', 'divide': 10}, 'pvboosttemp': {'value': 538, 'length': 2, 'type': 'num', 'divide': 10}, 'bat_dsp': {'value': 546, 'length': 2, 'type': 'num', 'divide': 10}, 'pbusvolt': {'value': 550, 'length': 2, 'type': 'num', 'divide': 10}, '#nbusvolt': {'value': 554, 'length': 2, 'type': 'num', 'divide': 10}, '#ipf': {'value': 558, 'length': 2, 'type': 'num', 'divide': 10}, '#realoppercent': {'value': 562, 'length': 2, 'type': 'num', 'divide': 100}, '#opfullwatt': {'value': 566, 'length': 4, 'type': 'num', 'divide': 10}, '#deratingmode': {'value': 574, 'length': 2, 'type': 'num', 'divide': 1}, 'eacharge_today': {'value': 606, 'length': 4, 'type': 'num', 'divide': 10}, 'eacharge_total': {'value': 614, 'length': 4, 'type': 'num', 'divide': 10}, 'batterytype': {'value': 634, 'length': 2, 'type': 'num', 'divide': 1}, 'uwsysworkmode': {'value': 666, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword1': {'value': 674, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword2': {'value': 678, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword3': {'value': 682, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword4': {'value': 686, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword5': {'value': 690, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword6': {'value': 694, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword7': {'value': 698, 'length': 2, 'type': 'num', 'divide': 1}, 'pdischarge1': {'value': 702, 'length': 4, 'type': 'num', 'divide': 10}, 'p1charge1': {'value': 710, 'length': 4, 'type': 'num', 'divide': 10}, 'vbat': {'value': 718, 'length': 2, 'type': 'num', 'divide': 10}, 'SOC': {'value': 722, 'length': 2, 'type': 'num', 'divide': 100}, 'pactouserr': {'value': 726, 'length': 4, 'type': 'num', 'divide': 10}, '#pactousers': {'value': 734, 'length': 4, 'type': 'num', 'divide': 10}, '#pactousert': {'value': 742, 'length': 4, 'type': 'num', 'divide': 10}, 'pactousertot': {'value': 750, 'length': 4, 'type': 'num', 'divide': 10}, 'pactogridr': {'value': 758, 'length': 4, 'type': 'num', 'divide': 10}, '#pactogrids': {'value': 766, 'length': 4, 'type': 'num', 'divide': 10}, '#pactogridt': {'value': 774, 'length': 4, 'type': 'num', 'divide': 10}, 'pactogridtot': {'value': 782, 'length': 4, 'type': 'num', 'divide': 10}, 'plocaloadr': {'value': 790, 'length': 4, 'type': 'num', 'divide': 10}, '#plocaloads': {'value': 798, 'length': 4, 'type': 'num', 'divide': 10}, '#plocaloadt': {'value': 806, 'length': 4, 'type': 'num', 'divide': 10}, 'plocaloadtot': {'value': 814, 'length': 4, 'type': 'num', 'divide': 10}, '#ipm': {'value': 822, 'length': 2, 'type': 'num', 'divide': 10}, '#battemp': {'value': 826, 'length': 2, 'type': 'num', 'divide': 10}, 'spdspstatus': {'value': 830, 'length': 2, 'type': 'num', 'divide': 10}, 'spbusvolt': {'value': 834, 'length': 2, 'type': 'num', 'divide': 10}, 'etouser_tod': {'value': 842, 'length': 4, 'type': 'num', 'divide': 10}, 'etouser_tot': {'value': 850, 'length': 4, 'type': 'num', 'divide': 10}, 'etogrid_tod': {'value': 858, 'length': 4, 'type': 'num', 'divide': 10}, 'etogrid_tot': {'value': 866, 'length': 4, 'type': 'num', 'divide': 10}, 'edischarge1_tod': {'value': 874, 'length': 4, 'type': 'num', 'divide': 10}, 'edischarge1_tot': {'value': 882, 'length': 4, 'type': 'num', 'divide': 10}, 'eharge1_tod': {'value': 890, 'length': 4, 'type': 'num', 'divide': 10}, 'eharge1_tot': {'value': 898, 'length': 4, 'type': 'num', 'divide': 10}, 'elocalload_tod': {'value': 906, 'length': 4, 'type': 'num', 'divide': 10}, 'elocalload_tot': {'value': 914, 'length': 4, 'type': 'num', 'divide': 10}} T060150X : {'decrypt': {'value': 'True'}, 'pvserial': {'value': 76, 'length': 10, 'type': 'text', 'divide': 10}, 'date': {'value': 136, 'divide': 10}, '#recortype': {'value': 154, 'length': 2, 'type': 'num'}, 'pvstatus': {'value': 158, 'length': 2, 'type': 'num'}, 'pvpowerin': {'value': 162, 'length': 4, 'type': 'num', 'divide': 10}, 'pv1voltage': {'value': 170, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1current': {'value': 174, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1watt': {'value': 178, 'length': 4, 'type': 'num', 'divide': 10}, 'pv2voltage': {'value': 186, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2current': {'value': 190, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2watt': {'value': 194, 'length': 4, 'type': 'num', 'divide': 10}, 'pvpowerout': {'value': 298, 'length': 4, 'type': 'numx', 'divide': 10}, 'pvfrequentie': {'value': 306, 'length': 2, 'type': 'num', 'divide': 100}, 'pvgridvoltage': {'value': 310, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent': {'value': 314, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower': {'value': 318, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage2': {'value': 326, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent2': {'value': 330, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower2': {'value': 334, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage3': {'value': 342, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent3': {'value': 346, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower3': {'value': 350, 'length': 4, 'type': 'num', 'divide': 10}, 'totworktime': {'value': 386, 'length': 4, 'type': 'num', 'divide': 7200}, 'eactoday': {'value': 370, 'length': 4, 'type': 'num', 'divide': 10}, 'eactotal': {'value': 378, 'length': 4, 'type': 'num', 'divide': 10}, 'epvtotal': {'value': 522, 'length': 4, 'type': 'num', 'divide': 10}, 'epv1today': {'value': 394, 'length': 4, 'type': 'num', 'divide': 10}, 'epv1total': {'value': 402, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2today': {'value': 410, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2total': {'value': 418, 'length': 4, 'type': 'num', 'divide': 10}, 'pvtemperature': {'value': 530, 'length': 2, 'type': 'num', 'divide': 10}, 'pvipmtemperature': {'value': 534, 'length': 2, 'type': 'num', 'divide': 10}, 'pvboosttemp': {'value': 538, 'length': 2, 'type': 'num', 'divide': 10}, 'bat_dsp': {'value': 546, 'length': 2, 'type': 'num', 'divide': 10}, 'pbusvolt': {'value': 550, 'length': 2, 'type': 'num', 'divide': 10}, '#nbusvolt': {'value': 554, 'length': 2, 'type': 'num', 'divide': 10}, '#ipf': {'value': 558, 'length': 2, 'type': 'num', 'divide': 10}, '#realoppercent': {'value': 562, 'length': 2, 'type': 'num', 'divide': 100}, '#opfullwatt': {'value': 566, 'length': 4, 'type': 'num', 'divide': 10}, '#deratingmode': {'value': 574, 'length': 2, 'type': 'num', 'divide': 1}, 'eacharge_today': {'value': 606, 'length': 4, 'type': 'num', 'divide': 10}, 'eacharge_total': {'value': 614, 'length': 4, 'type': 'num', 'divide': 10}, 'batterytype': {'value': 634, 'length': 2, 'type': 'num', 'divide': 1}, 'uwsysworkmode': {'value': 666, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword1': {'value': 674, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword2': {'value': 678, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword3': {'value': 682, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword4': {'value': 686, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword5': {'value': 690, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword6': {'value': 694, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword7': {'value': 698, 'length': 2, 'type': 'num', 'divide': 1}, 'pdischarge1': {'value': 702, 'length': 4, 'type': 'num', 'divide': 10}, 'p1charge1': {'value': 710, 'length': 4, 'type': 'num', 'divide': 10}, 'vbat': {'value': 718, 'length': 2, 'type': 'num', 'divide': 10}, 'SOC': {'value': 722, 'length': 2, 'type': 'num', 'divide': 100}, 'pactouserr': {'value': 726, 'length': 4, 'type': 'num', 'divide': 10}, '#pactousers': {'value': 734, 'length': 4, 'type': 'num', 'divide': 10}, '#pactousert': {'value': 742, 'length': 4, 'type': 'num', 'divide': 10}, 'pactousertot': {'value': 750, 'length': 4, 'type': 'num', 'divide': 10}, 'pactogridr': {'value': 758, 'length': 4, 'type': 'num', 'divide': 10}, '#pactogrids': {'value': 766, 'length': 4, 'type': 'num', 'divide': 10}, '#pactogridt': {'value': 774, 'length': 4, 'type': 'num', 'divide': 10}, 'pactogridtot': {'value': 782, 'length': 4, 'type': 'num', 'divide': 10}, 'plocaloadr': {'value': 790, 'length': 4, 'type': 'num', 'divide': 10}, '#plocaloads': {'value': 798, 'length': 4, 'type': 'num', 'divide': 10}, '#plocaloadt': {'value': 806, 'length': 4, 'type': 'num', 'divide': 10}, 'plocaloadtot': {'value': 814, 'length': 4, 'type': 'num', 'divide': 10}, '#ipm': {'value': 822, 'length': 2, 'type': 'num', 'divide': 10}, '#battemp': {'value': 826, 'length': 2, 'type': 'num', 'divide': 10}, 'spdspstatus': {'value': 830, 'length': 2, 'type': 'num', 'divide': 10}, 'spbusvolt': {'value': 834, 'length': 2, 'type': 'num', 'divide': 10}, 'etouser_tod': {'value': 842, 'length': 4, 'type': 'num', 'divide': 10}, 'etouser_tot': {'value': 850, 'length': 4, 'type': 'num', 'divide': 10}, 'etogrid_tod': {'value': 858, 'length': 4, 'type': 'num', 'divide': 10}, 'etogrid_tot': {'value': 866, 'length': 4, 'type': 'num', 'divide': 10}, 'edischarge1_tod': {'value': 874, 'length': 4, 'type': 'num', 'divide': 10}, 'edischarge1_tot': {'value': 882, 'length': 4, 'type': 'num', 'divide': 10}, 'eharge1_tod': {'value': 890, 'length': 4, 'type': 'num', 'divide': 10}, 'eharge1_tot': {'value': 898, 'length': 4, 'type': 'num', 'divide': 10}, 'elocalload_tod': {'value': 906, 'length': 4, 'type': 'num', 'divide': 10}, 'elocalload_tot': {'value': 914, 'length': 4, 'type': 'num', 'divide': 10}}
Grott external record whitelist 'recwl.txt' not found
Grott records whitelisted : {'0120', '0103', '5050', '0119', '5016', '0150', '5003', '5116', '5004', '5019', '5103', '5104', '0116', '5119', '5150', '0104'}
Grott settings:
_Generic: version: 2.6.1g verbose: True trace: False config file: grott.ini minrecl: 100 decrypt: True compat: False invtype: default include_all: False blockcmd: False noipf: False time: auto sendbuf: True timezone: local valueoffset: 6 offset: 6 inverterid: automatic mode: proxy grottip default grottport 5279 _MQTT: nomqtt False mqttip: localhost mqttport: 1883 mqtttopic: energy/growatt mqtttauth: False mqttuser: grott mqttpsw: secret _Growatt server: growattip: 47.91.67.66 growattport: 5279 _PVOutput: pvoutput: False pvurl: https://pvoutput.org/service/r2/addstatus.jsp pvapikey: yourapikey pvinverters: 1 pvsystemid: systemid1 _Influxdb: influx: False influx2: False database: grottdb ip: localhost port: 8086 user: grott password: secret organization: grottorg bucket: grottdb token: secret _Extension: extension: False extname: grottext extvar: {'none': 'none'}
Grott proxy mode started Hostname : cb88cbf3cd1b IP : 172.17.0.2 , port : 5279
All appears okay so far although I'm not sure why the listed IP is 172.17.0.2
When I login to the Growatt server and try and change the IP address of my Data Logger to 192.168.1.226 and enter the date as password, it says success in green but nothing happens?
What am I doing wrong?