Open jerodequin opened 4 months ago
Are you using SPH or sph? Think I remember it has to be SPH.
Thank you, have just tried stopping the server and changing to SPH in config but on restart of the server, I still get assigned a layout of T060103X rather than SPH after no matching record layout found.
Do you have the messages after startup that shows the configuration being used?
Do you have the messages after startup that shows the configuration being used?
Hello Johan, thanks for replying -
This is everything in the log immediately after starting grott:
2024/03/03 15:03:16 | stdout | - Data less then minimum record length, data not processed |
---|---|---|
2024/03/03 15:03:16 | stdout | <socket.socket fd=5, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 5279), raddr=('192.168.1.191', 44480)> |
2024/03/03 15:03:16 | stdout | - Growatt packet received: |
2024/03/03 15:03:16 | stdout | |
2024/03/03 15:03:16 | stdout | - Grott extension processing disabled |
2024/03/03 15:03:16 | stdout | - Grott Send data to Influx disabled |
2024/03/03 15:03:16 | stdout | - Grott Send data to PVOutput disabled |
2024/03/03 15:03:16 | stdout | - MQTT message message sent |
2024/03/03 15:03:16 | stdout | - Grott MQTT topic used : energy/growatt |
2024/03/03 15:03:16 | stdout | "pvtemperature": 334, "pvipmtemperature": 533}} |
2024/03/03 15:03:16 | stdout | "epv1today": 3508, "epv1total": 6902925, "epv2today": 58, "epv2total": 889, |
2024/03/03 15:03:16 | stdout | "totworktime": 0, "pvenergytoday": 0, "pvenergytotal": 0, "epvtotal": 116, |
2024/03/03 15:03:16 | stdout | 0, "pvgridvoltage3": 0, "pvgridcurrent3": 0, "pvgridpower3": 2186089342, |
2024/03/03 15:03:16 | stdout | "pvgridpower": 0, "pvgridvoltage2": 0, "pvgridcurrent2": 0, "pvgridpower2": |
2024/03/03 15:03:16 | stdout | "pvpowerout": 0, "pvfrequentie": 0, "pvgridvoltage": 0, "pvgridcurrent": 0, |
2024/03/03 15:03:16 | stdout | "pv1watt": 16450, "pv2voltage": 2110, "pv2current": 95, "pv2watt": 20134, |
2024/03/03 15:03:16 | stdout | "pvstatus": 5, "pvpowerin": 36500, "pv1voltage": 1775, "pv1current": 92, |
2024/03/03 15:03:16 | stdout | "values": {"datalogserial": "JPC8CLS0TJ", "pvserial": "OUCTCJM022", |
2024/03/03 15:03:16 | stdout | {"device": "OUCTCJM022", "time": "2024-03-03T15:02:09", "buffered": "yes", |
2024/03/03 15:03:16 | stdout | - MQTT jsonmsg: |
2024/03/03 15:03:16 | stdout | - pvipmtemperature : 53.3 |
2024/03/03 15:03:16 | stdout | - pvtemperature : 33.4 |
2024/03/03 15:03:16 | stdout | - epv2total : 88.9 |
2024/03/03 15:03:16 | stdout | - epv2today : 5.8 |
2024/03/03 15:03:16 | stdout | - epv1total : 690292.5 |
2024/03/03 15:03:16 | stdout | - epv1today : 350.8 |
2024/03/03 15:03:16 | stdout | - epvtotal : 11.6 |
2024/03/03 15:03:16 | stdout | - pvenergytotal : 0.0 |
2024/03/03 15:03:16 | stdout | - pvenergytoday : 0.0 |
2024/03/03 15:03:16 | stdout | - totworktime : 0.0 |
2024/03/03 15:03:16 | stdout | - pvgridpower3 : 218608934.2 |
2024/03/03 15:03:16 | stdout | - pvgridcurrent3 : 0.0 |
2024/03/03 15:03:16 | stdout | - pvgridvoltage3 : 0.0 |
2024/03/03 15:03:16 | stdout | - pvgridpower2 : 0.0 |
2024/03/03 15:03:16 | stdout | - pvgridcurrent2 : 0.0 |
2024/03/03 15:03:16 | stdout | - pvgridvoltage2 : 0.0 |
2024/03/03 15:03:16 | stdout | - pvgridpower : 0.0 |
2024/03/03 15:03:16 | stdout | - pvgridcurrent : 0.0 |
2024/03/03 15:03:16 | stdout | - pvgridvoltage : 0.0 |
2024/03/03 15:03:16 | stdout | - pvfrequentie : 0.0 |
2024/03/03 15:03:16 | stdout | - pvpowerout : 0.0 |
2024/03/03 15:03:16 | stdout | - pv2watt : 2013.4 |
2024/03/03 15:03:16 | stdout | - pv2current : 9.5 |
2024/03/03 15:03:16 | stdout | - pv2voltage : 211.0 |
2024/03/03 15:03:16 | stdout | - pv1watt : 1645.0 |
2024/03/03 15:03:16 | stdout | - pv1current : 9.2 |
2024/03/03 15:03:16 | stdout | - pv1voltage : 177.5 |
2024/03/03 15:03:16 | stdout | - pvpowerin : 3650.0 |
2024/03/03 15:03:16 | stdout | - pvstatus : 5 |
2024/03/03 15:03:16 | stdout | - pvserial : OUCTCJM022 |
2024/03/03 15:03:16 | stdout | - datalogserial : JPC8CLS0TJ |
2024/03/03 15:03:16 | stdout | - Grott values retrieved: |
2024/03/03 15:03:16 | stdout | - date-time: 2024-03-03T15:02:09 |
2024/03/03 15:03:16 | stdout | - Grott data record date/time processing started |
2024/03/03 15:03:16 | stdout | |
2024/03/03 15:03:16 | stdout | - record layout : T06NNNNX |
2024/03/03 15:03:16 | stdout | - offset : 6 |
2024/03/03 15:03:16 | stdout | - decrypt : True |
2024/03/03 15:03:16 | stdout | - Growatt new layout processing |
2024/03/03 15:03:16 | stdout | - Inverter serial not recognised - using inverter type default |
2024/03/03 15:03:16 | stdout | - Possible Inverter serial OUCTCJM022 |
2024/03/03 15:03:16 | stdout | 000000000000000000000000000000000000000000000000000000000e13f |
2024/03/03 15:03:16 | stdout | 0000c300400000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:03:16 | stdout | 000000000010cfb0cf7000300300012000f0055004e0005000200000063006300000000000000 |
2024/03/03 15:03:16 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:03:16 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:03:16 | stdout | 000f520000002400000c3200008ef800001450000000800002000002da0002000003530000000 |
2024/03/03 15:03:16 | stdout | 00000000000046504e100230000091b0000000004270000000000000000000000000000008100 |
2024/03/03 15:03:16 | stdout | 000000004150415000000cfb0cf800030e420cfb0cfa0cf90cf90cfb0cfa0cf80cf8000000000 |
2024/03/03 15:03:16 | stdout | 100000000006314be00000008000044d4451000000003001b0064163000000000000000000000 |
2024/03/03 15:03:16 | stdout | 00000000000000000000000000000000000000000000000000000000000000000003e80000012 |
2024/03/03 15:03:16 | stdout | 02800000b1b0000005c00000338000000090000097d0000002600000a550000002f00000efd00 |
2024/03/03 15:03:16 | stdout | 00000000000000007a15000015180000000000000000000015180000000800050bc731ce00000 |
2024/03/03 15:03:16 | stdout | 0000001000000000000000000021300630000000000000000000000000000000000007a150000 |
2024/03/03 15:03:16 | stdout | 00091b00000000000000010000000000000000000003e80464000500000000000000000000000 |
2024/03/03 15:03:16 | stdout | 16d0000021510b810e30000000000000000000000000000000000000000000000000000002300 |
2024/03/03 15:03:16 | stdout | 000000000000000000000000000000000000000000000000000000000000000007f2014e01110 |
2024/03/03 15:03:16 | stdout | 40069548d0000003a00000379000000460000046d000000000000000000000000000000000000 |
2024/03/03 15:03:16 | stdout | 7e096c008a00008329000000000000000000000000000000000000000000000000007400000db |
2024/03/03 15:03:16 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000824d13 |
2024/03/03 15:03:16 | stdout | 007c000500008e9406ef005c00004042083e005f00004ea6000170a009b907e708a200fa00000 |
2024/03/03 15:03:16 | stdout | f554354434a4d30323200000000000000000000000000000000000000001803030f0209030000 |
2024/03/03 15:03:16 | stdout | 00030006033f01504a504338434c5330544a00000000000000000000000000000000000000004 |
2024/03/03 15:03:16 | stdout | - Growatt plain data: |
2024/03/03 15:03:16 | stdout | - Grott Growatt data decrypted |
2024/03/03 15:03:16 | stdout | - Growatt data decrypted V2 |
2024/03/03 15:03:16 | stdout | - Record layout used : T06NNNNX |
2024/03/03 15:03:16 | stdout | - no matching record layout found, try generic |
2024/03/03 15:03:16 | stdout | - layout : T060150X |
2024/03/03 15:03:16 | stdout | - Grott data record length 839 |
2024/03/03 15:03:16 | stdout | - Grott automatic protocol detection |
2024/03/03 15:03:16 | stdout | \x6f\x96\x5e |
2024/03/03 15:03:16 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:03:16 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77 |
2024/03/03 15:03:16 | stdout | \x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74 |
2024/03/03 15:03:16 | stdout | \x14\x61\x17\x74\x47\x72\x6f\x77\x61\x74\x74\x47\xb1\x6f\x37\x61\x74\x74\x47 |
2024/03/03 15:03:16 | stdout | \x74\x77\x47\x42\x6f\x65\x61\x7b\x74\x12\x72\x21\x77\x64\x74\x76\x47\x72\x6f |
2024/03/03 15:03:16 | stdout | \x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x46\x7e\x94\x7b\x96 |
2024/03/03 15:03:16 | stdout | \x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74 |
2024/03/03 15:03:16 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:03:16 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77 |
2024/03/03 15:03:16 | stdout | \x70\x6f\x77\x62\x27\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74 |
2024/03/03 15:03:16 | stdout | \x77\x61\xfa\x8c\x47\x72\x7b\x27\x61\x74\x74\xc7\x72\x6d\x77\x61\x76\xae\x47 |
2024/03/03 15:03:16 | stdout | \x74\x74\x47\x72\x6f\x77\xe0\x74\x74\x48\x20\x6f\x77\x61\x50\x74\x47\x7e\x5d |
2024/03/03 15:03:16 | stdout | \x47\x72\x66\x6c\x61\x74\x74\x47\x76\x48\x77\x61\x74\x74\x47\x72\x6f\x77\x61 |
2024/03/03 15:03:16 | stdout | \x97\x7b\x99\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x76\x0a\x73\x80\x74\x57 |
2024/03/03 15:03:16 | stdout | \x6d\x8c\x74\x44\x7c\x2d\x7b\x9a\x78\x8e\x4b\x8b\x63\x8e\x6d\x8f\x78\xbd\x7e |
2024/03/03 15:03:16 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x36\x31\x35\x24\x47\x72\x63\x8c |
2024/03/03 15:03:16 | stdout | \x72\x6f\x33\xb5\x31\x64\x47\x72\x6f\x74\x61\x6f\x74\x23\x64\x5f\x77\x61\x74 |
2024/03/03 15:03:16 | stdout | \x77\x62\x9c\x74\x47\x73\x4e\x77\x61\x74\x74\x47\x11\x7b\xc9\x61\x74\x74\x4f |
2024/03/03 15:03:16 | stdout | \x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f |
2024/03/03 15:03:16 | stdout | \x68\x72\x6f\x79\x9c\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61 |
2024/03/03 15:03:16 | stdout | \x6f\x77\x61\x7d\x74\x47\x7b\x12\x77\x61\x74\x52\x47\x72\x65\x22\x61\x74\x74 |
2024/03/03 15:03:16 | stdout | \xa6\x45\xba\x47\x72\x6f\x5f\x61\x74\x7f\x5c\x72\x6f\x77\x3d\x74\x74\x44\x4a |
2024/03/03 15:03:16 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x7a\x6f\x61\x74\x74\x4f\x72\x6a\x7c |
2024/03/03 15:03:16 | stdout | \x72\x15\x62\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x3d\x67\x6f\x77\x74\x6c |
2024/03/03 15:03:16 | stdout | \x77\x02\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47 |
2024/03/03 15:03:16 | stdout | \x74\x74\x47\x72\x6f\x77\x61\x75\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x70\x7c |
2024/03/03 15:03:16 | stdout | \x47\x72\x6f\x77\x61\x74\x77\xaf\x76\x0b\x77\x64\x74\x74\x47\x72\x6f\x77\x61 |
2024/03/03 15:03:16 | stdout | \x6f\x77\x42\x74\x74\x4e\x69\x6f\x77\x61\x74\x74\x47\x72\x6e\x77\x61\x74\x74 |
2024/03/03 15:03:16 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:03:16 | stdout | \x3a\x46\x63\x6e\x1a\x61\x74\x76\x52\x62\xd7\x67\x82\x74\x74\x47\x72\x6f\x77 |
2024/03/03 15:03:16 | stdout | \x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x70\x93\x75 |
2024/03/03 15:03:16 | stdout | \x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47 |
2024/03/03 15:03:16 | stdout | \x74\x74\x43\x1f\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f |
2024/03/03 15:03:16 | stdout | \x47\x7f\xdb\x77\x08\x20\xf9\x47\x72\x6f\x4d\x61\x74\x77\x3e\x72\x6f\x77\x27 |
2024/03/03 15:03:16 | stdout | \x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x00\x74 |
2024/03/03 15:03:16 | stdout | \x2c\x67\x0a\x4e\x1e\x6f\xfd\x61\x74\xf7\x6e\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:03:16 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\xf5 |
2024/03/03 15:03:16 | stdout | \x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74 |
2024/03/03 15:03:16 | stdout | \x77\x3e\x74\x74\x09\xd4\x6f\x76\x11\xd4\x7d\xfe\x75\x88\x7f\xc3\x74\x8e\x47 |
2024/03/03 15:03:16 | stdout | \x74\x74\x3b\x72\x6a\x77\x61\xfa\xe0\x41\x9d\x6f\x2b\x61\x74\x34\x05\x7a\x51 |
2024/03/03 15:03:16 | stdout | \x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x79\x77\x77\x48\x70\x66\x74\x61 |
2024/03/03 15:03:16 | stdout | \x20\x22\x22\x20\x37\x0d\x3f\x5f\x45\x53\x74\x74\x47\x72\x6f\x77\x61\x74\x74 |
2024/03/03 15:03:16 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:03:16 | stdout | \x00\x03\x00\x06\x03\x3f\x01\x50\x0d\x22\x2c\x4f\x22\x38\x27\x77\x26\x25\x77 |
2024/03/03 15:03:16 | stdout | - Growatt original Data: |
2024/03/03 15:03:16 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:03:16 | stdout | - Growatt packet received: |
2024/03/03 15:03:16 | stdout | |
2024/03/03 15:03:14 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:03:14 | stdout | <socket.socket fd=5, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 5279), raddr=('192.168.1.191', 44480)> |
2024/03/03 15:03:14 | stdout | - Growatt packet received: |
2024/03/03 15:03:14 | stdout | |
2024/03/03 15:03:14 | stdout | - Grott data ack record or data record not defined no processing done |
2024/03/03 15:03:14 | stdout | 00000000000b1e1 |
2024/03/03 15:03:14 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:03:14 | stdout | 0097d00000000000108760213000000000063006400004510000044d400510055000000000000 |
2024/03/03 15:03:14 | stdout | 000000000000000000000000000000000000000000000000000000002600000a5500000009000 |
2024/03/03 15:03:14 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:03:14 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:03:14 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:03:14 | stdout | 77000000000000000000000000000000000000000079957a11000000000000000000000000000 |
2024/03/03 15:03:14 | stdout | 0000000000000000000000080b2000009cb0000137e096300000000008900000000ffff868c01 |
2024/03/03 15:03:14 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:03:14 | stdout | 0000000008ca00000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:03:14 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:03:14 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:03:14 | stdout | 7994000500000000000000000000000000000000000006c3005d0813005f00000000000000000 |
2024/03/03 15:03:14 | stdout | f554354434a4d30323200000000000000000000000000000000000000001803030f030e027918 |
2024/03/03 15:03:14 | stdout | 004e0006024101364a504338434c5330544a00000000000000000000000000000000000000004 |
2024/03/03 15:03:14 | stdout | - Growatt plain data: |
2024/03/03 15:03:14 | stdout | - Grott Growatt data decrypted |
2024/03/03 15:03:14 | stdout | - Growatt data decrypted V2 |
2024/03/03 15:03:14 | stdout | - Record layout used : T060136X |
2024/03/03 15:03:14 | stdout | - no matching record layout found, try generic |
2024/03/03 15:03:14 | stdout | - layout : T060136X |
2024/03/03 15:03:14 | stdout | - Grott data record length 585 |
2024/03/03 15:03:14 | stdout | - Grott automatic protocol detection |
2024/03/03 15:03:14 | stdout | \x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\xc3\x8e |
2024/03/03 15:03:14 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:03:14 | stdout | \x21\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77 |
2024/03/03 15:03:14 | stdout | \x72\x6f\x77\x61\x74\x17\x47\x16\x6f\x77\x24\x64\x74\x47\x36\xbb\x77\x30\x74 |
2024/03/03 15:03:14 | stdout | \x22\x61\x74\x74\x4e\x72\x6f\x7e\x1c\x74\x74\x47\x72\x6f\x76\x69\x02\x76\x54 |
2024/03/03 15:03:14 | stdout | \x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x52\x47\x72\x65 |
2024/03/03 15:03:14 | stdout | \x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61 |
2024/03/03 15:03:14 | stdout | \x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74 |
2024/03/03 15:03:14 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:03:14 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77 |
2024/03/03 15:03:14 | stdout | \x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74 |
2024/03/03 15:03:14 | stdout | \x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47 |
2024/03/03 15:03:14 | stdout | \x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f |
2024/03/03 15:03:14 | stdout | \x47\x72\x6f\x77\x61\x74\x0d\xd2\x08\x7e\x77\x61\x74\x74\x47\x72\x6f\x77\x61 |
2024/03/03 15:03:14 | stdout | \x90\xf1\xed\x75\x03\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74 |
2024/03/03 15:03:14 | stdout | \x68\xbf\x74\x47\x61\x11\x7e\x02\x74\x74\x47\x72\x6f\xfe\x61\x74\x74\x47\x8d |
2024/03/03 15:03:14 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\xc7\xc0\x6f\x77 |
2024/03/03 15:03:14 | stdout | \x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74 |
2024/03/03 15:03:14 | stdout | \x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47 |
2024/03/03 15:03:14 | stdout | \x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f |
2024/03/03 15:03:14 | stdout | \x47\x72\x6f\x77\x61\x74\x74\xcb\xd2\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61 |
2024/03/03 15:03:14 | stdout | \x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74 |
2024/03/03 15:03:14 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:03:14 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77 |
2024/03/03 15:03:14 | stdout | \x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74 |
2024/03/03 15:03:14 | stdout | \x77\x61\x74\x74\x41\xb1\x6f\x2a\x69\x67\x74\x18\x72\x6f\x77\x61\x74\x74\x47 |
2024/03/03 15:03:14 | stdout | \x6c\x0d\xd3\x72\x6a\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f |
2024/03/03 15:03:14 | stdout | \x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x79\x77\x77\x48\x71\x61\x75\x18 |
2024/03/03 15:03:14 | stdout | \x20\x22\x22\x20\x37\x0d\x3f\x5f\x45\x53\x74\x74\x47\x72\x6f\x77\x61\x74\x74 |
2024/03/03 15:03:14 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:03:14 | stdout | \x00\x4e\x00\x06\x02\x41\x01\x36\x0d\x22\x2c\x4f\x22\x38\x27\x77\x26\x25\x77 |
2024/03/03 15:03:14 | stdout | - Growatt original Data: |
2024/03/03 15:03:14 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:03:14 | stdout | - Growatt packet received: |
2024/03/03 15:03:14 | stdout | |
2024/03/03 15:02:50 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:50 | stdout | <socket.socket fd=5, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 5279), raddr=('192.168.1.191', 44480)> |
2024/03/03 15:02:50 | stdout | - Growatt packet received: |
2024/03/03 15:02:50 | stdout | |
2024/03/03 15:02:50 | stdout | - Grott data ack record or data record not defined no processing done |
2024/03/03 15:02:50 | stdout | 000000000006edd |
2024/03/03 15:02:50 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:50 | stdout | 0097d00000000000108760213000000000063006400004510000044d400500054000000000000 |
2024/03/03 15:02:50 | stdout | 000000000000000000000000000000000000000000000000000000002600000a5500000009000 |
2024/03/03 15:02:50 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:50 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:50 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:50 | stdout | 6c000000000000000000000000000000000000000079957a11000000000000000000000000000 |
2024/03/03 15:02:50 | stdout | 00000000000000000000000829200000caf00001381096000000000008b00000000ffff824601 |
2024/03/03 15:02:50 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:50 | stdout | 0000000008f5c0000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:50 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:50 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:50 | stdout | 7994000500000000000000000000000000000000000006da005e0829006000000000000000000 |
2024/03/03 15:02:50 | stdout | f554354434a4d30323200000000000000000000000000000000000000001803030f0232027918 |
2024/03/03 15:02:50 | stdout | 004d0006024101364a504338434c5330544a00000000000000000000000000000000000000004 |
2024/03/03 15:02:50 | stdout | - Growatt plain data: |
2024/03/03 15:02:50 | stdout | - Grott Growatt data decrypted |
2024/03/03 15:02:50 | stdout | - Growatt data decrypted V2 |
2024/03/03 15:02:50 | stdout | - Record layout used : T060136X |
2024/03/03 15:02:50 | stdout | - no matching record layout found, try generic |
2024/03/03 15:02:50 | stdout | - layout : T060136X |
2024/03/03 15:02:50 | stdout | - Grott data record length 585 |
2024/03/03 15:02:50 | stdout | - Grott automatic protocol detection |
2024/03/03 15:02:50 | stdout | \x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x1c\xb2 |
2024/03/03 15:02:50 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:02:50 | stdout | \x20\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77 |
2024/03/03 15:02:50 | stdout | \x72\x6f\x77\x61\x74\x17\x47\x16\x6f\x77\x24\x64\x74\x47\x36\xbb\x77\x31\x74 |
2024/03/03 15:02:50 | stdout | \x22\x61\x74\x74\x4e\x72\x6f\x7e\x1c\x74\x74\x47\x72\x6f\x76\x69\x02\x76\x54 |
2024/03/03 15:02:50 | stdout | \x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x52\x47\x72\x65 |
2024/03/03 15:02:50 | stdout | \x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61 |
2024/03/03 15:02:50 | stdout | \x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74 |
2024/03/03 15:02:50 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:02:50 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77 |
2024/03/03 15:02:50 | stdout | \x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74 |
2024/03/03 15:02:50 | stdout | \x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47 |
2024/03/03 15:02:50 | stdout | \x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f |
2024/03/03 15:02:50 | stdout | \x47\x72\x6f\x77\x61\x74\x0d\xd2\x08\x7e\x77\x61\x74\x74\x47\x72\x6f\x77\x61 |
2024/03/03 15:02:50 | stdout | \x90\xf5\x27\x75\x18\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74 |
2024/03/03 15:02:50 | stdout | \x6d\xdb\x74\x47\x61\xee\x7e\x01\x74\x74\x47\x72\x6f\xfc\x61\x74\x74\x47\x8d |
2024/03/03 15:02:50 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\xc5\xe0\x6f\x77 |
2024/03/03 15:02:50 | stdout | \x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74 |
2024/03/03 15:02:50 | stdout | \x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47 |
2024/03/03 15:02:50 | stdout | \x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f |
2024/03/03 15:02:50 | stdout | \x47\x72\x6f\x77\x61\x74\x74\xc8\x2e\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61 |
2024/03/03 15:02:50 | stdout | \x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74 |
2024/03/03 15:02:50 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:02:50 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77 |
2024/03/03 15:02:50 | stdout | \x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74 |
2024/03/03 15:02:50 | stdout | \x77\x61\x74\x74\x41\xa8\x6f\x29\x69\x5d\x74\x27\x72\x6f\x77\x61\x74\x74\x47 |
2024/03/03 15:02:50 | stdout | \x6c\x0d\xd3\x72\x6a\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f |
2024/03/03 15:02:50 | stdout | \x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x79\x77\x77\x48\x70\x5d\x75\x18 |
2024/03/03 15:02:50 | stdout | \x20\x22\x22\x20\x37\x0d\x3f\x5f\x45\x53\x74\x74\x47\x72\x6f\x77\x61\x74\x74 |
2024/03/03 15:02:50 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:02:50 | stdout | \x00\x4d\x00\x06\x02\x41\x01\x36\x0d\x22\x2c\x4f\x22\x38\x27\x77\x26\x25\x77 |
2024/03/03 15:02:50 | stdout | - Growatt original Data: |
2024/03/03 15:02:50 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:50 | stdout | - Growatt packet received: |
2024/03/03 15:02:50 | stdout | |
2024/03/03 15:02:46 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:46 | stdout | <socket.socket fd=5, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 5279), raddr=('192.168.1.191', 44480)> |
2024/03/03 15:02:46 | stdout | - Growatt packet received: |
2024/03/03 15:02:46 | stdout | |
2024/03/03 15:02:46 | stdout | - Grott extension processing disabled |
2024/03/03 15:02:46 | stdout | - Grott Send data to Influx disabled |
2024/03/03 15:02:46 | stdout | - Grott Send data to PVOutput disabled |
2024/03/03 15:02:46 | stdout | - MQTT message message sent |
2024/03/03 15:02:46 | stdout | - Grott MQTT topic used : energy/growatt |
2024/03/03 15:02:46 | stdout | "pvtemperature": 333, "pvipmtemperature": 533}} |
2024/03/03 15:02:46 | stdout | "epv1today": 3506, "epv1total": 6902341, "epv2today": 57, "epv2total": 888, |
2024/03/03 15:02:46 | stdout | "totworktime": 0, "pvenergytoday": 0, "pvenergytotal": 0, "epvtotal": 114, |
2024/03/03 15:02:46 | stdout | 0, "pvgridvoltage3": 0, "pvgridcurrent3": 0, "pvgridpower3": 225448848, |
2024/03/03 15:02:46 | stdout | "pvgridpower": 0, "pvgridvoltage2": 0, "pvgridcurrent2": 0, "pvgridpower2": |
2024/03/03 15:02:46 | stdout | "pvpowerout": 0, "pvfrequentie": 0, "pvgridvoltage": 0, "pvgridcurrent": 0, |
2024/03/03 15:02:46 | stdout | "pv1watt": 1389, "pv2voltage": 1986, "pv2current": 8, "pv2watt": 1739, |
2024/03/03 15:02:46 | stdout | "pvstatus": 5, "pvpowerin": 3100, "pv1voltage": 1682, "pv1current": 8, |
2024/03/03 15:02:46 | stdout | "values": {"datalogserial": "JPC8CLS0TJ", "pvserial": "OUCTCJM022", |
2024/03/03 15:02:46 | stdout | {"device": "OUCTCJM022", "time": "2024-03-03T14:57:09", "buffered": "yes", |
2024/03/03 15:02:46 | stdout | - MQTT jsonmsg: |
2024/03/03 15:02:46 | stdout | - pvipmtemperature : 53.3 |
2024/03/03 15:02:46 | stdout | - pvtemperature : 33.3 |
2024/03/03 15:02:46 | stdout | - epv2total : 88.8 |
2024/03/03 15:02:46 | stdout | - epv2today : 5.7 |
2024/03/03 15:02:46 | stdout | - epv1total : 690234.1 |
2024/03/03 15:02:46 | stdout | - epv1today : 350.6 |
2024/03/03 15:02:46 | stdout | - epvtotal : 11.4 |
2024/03/03 15:02:46 | stdout | - pvenergytotal : 0.0 |
2024/03/03 15:02:46 | stdout | - pvenergytoday : 0.0 |
2024/03/03 15:02:46 | stdout | - totworktime : 0.0 |
2024/03/03 15:02:46 | stdout | - pvgridpower3 : 22544884.8 |
2024/03/03 15:02:46 | stdout | - pvgridcurrent3 : 0.0 |
2024/03/03 15:02:46 | stdout | - pvgridvoltage3 : 0.0 |
2024/03/03 15:02:46 | stdout | - pvgridpower2 : 0.0 |
2024/03/03 15:02:46 | stdout | - pvgridcurrent2 : 0.0 |
2024/03/03 15:02:46 | stdout | - pvgridvoltage2 : 0.0 |
2024/03/03 15:02:46 | stdout | - pvgridpower : 0.0 |
2024/03/03 15:02:46 | stdout | - pvgridcurrent : 0.0 |
2024/03/03 15:02:46 | stdout | - pvgridvoltage : 0.0 |
2024/03/03 15:02:46 | stdout | - pvfrequentie : 0.0 |
2024/03/03 15:02:46 | stdout | - pvpowerout : 0.0 |
2024/03/03 15:02:46 | stdout | - pv2watt : 173.9 |
2024/03/03 15:02:46 | stdout | - pv2current : 0.8 |
2024/03/03 15:02:46 | stdout | - pv2voltage : 198.6 |
2024/03/03 15:02:46 | stdout | - pv1watt : 138.9 |
2024/03/03 15:02:46 | stdout | - pv1current : 0.8 |
2024/03/03 15:02:46 | stdout | - pv1voltage : 168.2 |
2024/03/03 15:02:46 | stdout | - pvpowerin : 310.0 |
2024/03/03 15:02:46 | stdout | - pvstatus : 5 |
2024/03/03 15:02:46 | stdout | - pvserial : OUCTCJM022 |
2024/03/03 15:02:46 | stdout | - datalogserial : JPC8CLS0TJ |
2024/03/03 15:02:46 | stdout | - Grott values retrieved: |
2024/03/03 15:02:46 | stdout | - date-time: 2024-03-03T14:57:09 |
2024/03/03 15:02:46 | stdout | - Grott data record date/time processing started |
2024/03/03 15:02:46 | stdout | |
2024/03/03 15:02:46 | stdout | - record layout : T06NNNNX |
2024/03/03 15:02:46 | stdout | - offset : 6 |
2024/03/03 15:02:46 | stdout | - decrypt : True |
2024/03/03 15:02:46 | stdout | - Growatt new layout processing |
2024/03/03 15:02:46 | stdout | - Inverter serial not recognised - using inverter type default |
2024/03/03 15:02:46 | stdout | - Possible Inverter serial OUCTCJM022 |
2024/03/03 15:02:46 | stdout | 0000000000000000000000000000000000000000000000000000000007e8f |
2024/03/03 15:02:46 | stdout | 0000c300400000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:46 | stdout | 000000000010cfb0cf800030030001100010054004e0005000200000063006300000000000000 |
2024/03/03 15:02:46 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:46 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:46 | stdout | 000f510000002400000c3200000c1c000008980000007f0002000002da0002000003530000000 |
2024/03/03 15:02:46 | stdout | 00000000000046504e100230000091b0000000004270000000000000000000000000000008000 |
2024/03/03 15:02:46 | stdout | 000000004150415000000cfb0cf700030e420cfb0cfb0cfa0cf90cfb0cfa0cf80cf8000000000 |
2024/03/03 15:02:46 | stdout | 100000000006314be00000008000044d444fc00000004001b0064163000000000000000000000 |
2024/03/03 15:02:46 | stdout | 00000000000000000000000000000000000000000000000000000000000000000003e80000012 |
2024/03/03 15:02:46 | stdout | 02800000b1b0000005b00000337000000090000097d0000002600000a550000002f00000efd00 |
2024/03/03 15:02:46 | stdout | 000000000000000002ce000009600000000000000000000009600000000800050bc931ce00000 |
2024/03/03 15:02:46 | stdout | 00000010000000000000000000213006300000000000000000000000000000000000002ce0000 |
2024/03/03 15:02:46 | stdout | 00091b00000000000000010000000000000000000003e80464000500000000000000000000000 |
2024/03/03 15:02:46 | stdout | 16b0000021510b810e50000000000000000000000000000000000000000000000000000002300 |
2024/03/03 15:02:46 | stdout | 000000000000000000000000000000000000000000000000000000000000000007f1014d011a0 |
2024/03/03 15:02:46 | stdout | 2006952450000003900000378000000450000046c000000000000000000000000000000000000 |
2024/03/03 15:02:46 | stdout | 900958001100000d2e000000000000000000000000000000000000000000000000007200000db |
2024/03/03 15:02:46 | stdout | 000000000000000000000000000000000000000000000000000000000000000000000000d7013 |
2024/03/03 15:02:46 | stdout | 007c000500000c1c069200080000056d07c20008000006cb000170a009bd07e808a100fa00000 |
2024/03/03 15:02:46 | stdout | f554354434a4d30323200000000000000000000000000000000000000001803030e3909030000 |
2024/03/03 15:02:46 | stdout | 00020006033f01504a504338434c5330544a00000000000000000000000000000000000000004 |
2024/03/03 15:02:46 | stdout | - Growatt plain data: |
2024/03/03 15:02:46 | stdout | - Grott Growatt data decrypted |
2024/03/03 15:02:46 | stdout | - Growatt data decrypted V2 |
2024/03/03 15:02:46 | stdout | - Record layout used : T06NNNNX |
2024/03/03 15:02:46 | stdout | - no matching record layout found, try generic |
2024/03/03 15:02:46 | stdout | - layout : T060150X |
2024/03/03 15:02:46 | stdout | - Grott data record length 839 |
2024/03/03 15:02:46 | stdout | - Grott automatic protocol detection |
2024/03/03 15:02:46 | stdout | \x6f\x09\xee |
2024/03/03 15:02:46 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:02:46 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77 |
2024/03/03 15:02:46 | stdout | \x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74 |
2024/03/03 15:02:46 | stdout | \x14\x61\x17\x74\x47\x72\x6f\x77\x61\x74\x74\x47\xb1\x6f\x37\x61\x74\x74\x47 |
2024/03/03 15:02:46 | stdout | \x74\x77\x47\x42\x6f\x66\x61\x75\x74\x13\x72\x21\x77\x64\x74\x76\x47\x72\x6f |
2024/03/03 15:02:46 | stdout | \x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x46\x7e\x94\x7b\x99 |
2024/03/03 15:02:46 | stdout | \x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74 |
2024/03/03 15:02:46 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:02:46 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77 |
2024/03/03 15:02:46 | stdout | \x70\x6f\x77\x62\x27\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74 |
2024/03/03 15:02:46 | stdout | \x77\x61\x78\x68\x47\x72\x67\xef\x61\x74\x74\x38\x72\x6d\x77\x61\x76\xae\x47 |
2024/03/03 15:02:46 | stdout | \x74\x74\x47\x72\x6f\x77\xe1\x74\x74\x48\x23\x6f\x77\x61\x50\x74\x47\x7e\x5d |
2024/03/03 15:02:46 | stdout | \x47\x72\x66\x6c\x61\x74\x74\x47\x76\x48\x77\x61\x74\x74\x47\x72\x6f\x77\x61 |
2024/03/03 15:02:46 | stdout | \x97\x7b\x99\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x76\x0a\x73\x80\x74\x57 |
2024/03/03 15:02:46 | stdout | \x6d\x83\x74\x44\x7c\x2d\x7b\x9a\x78\x8f\x4b\x88\x63\x8e\x6d\x8f\x78\xbd\x7e |
2024/03/03 15:02:46 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x36\x31\x35\x24\x47\x72\x63\x8c |
2024/03/03 15:02:46 | stdout | \x72\x6f\x33\xb5\x30\x88\x47\x72\x6f\x73\x61\x6f\x74\x23\x64\x5f\x77\x61\x74 |
2024/03/03 15:02:46 | stdout | \x77\x62\x9c\x74\x47\x73\x4e\x77\x61\x74\x74\x47\x11\x7b\xc9\x61\x74\x74\x4f |
2024/03/03 15:02:46 | stdout | \x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f |
2024/03/03 15:02:46 | stdout | \x68\x72\x6f\x79\x9c\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61 |
2024/03/03 15:02:46 | stdout | \x6f\x77\x61\x7d\x74\x47\x7b\x12\x77\x61\x74\x52\x47\x72\x65\x22\x61\x74\x74 |
2024/03/03 15:02:46 | stdout | \xa8\x45\xba\x47\x72\x6f\x5f\x61\x74\x7f\x5c\x72\x6f\x77\x3a\x74\x74\x44\x45 |
2024/03/03 15:02:46 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x66\x17\x61\x74\x74\x4f\x72\x6a\x7c |
2024/03/03 15:02:46 | stdout | \x72\x6d\xb9\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x45\xbc\x6f\x77\x68\x14 |
2024/03/03 15:02:46 | stdout | \x77\x02\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47 |
2024/03/03 15:02:46 | stdout | \x74\x74\x47\x72\x6f\x77\x61\x75\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x70\x7c |
2024/03/03 15:02:46 | stdout | \x47\x72\x6f\x77\x61\x74\x77\xaf\x76\x0b\x77\x64\x74\x74\x47\x72\x6f\x77\x61 |
2024/03/03 15:02:46 | stdout | \x6f\x77\x42\x74\x74\x4e\x69\x6f\x77\x61\x74\x74\x47\x72\x6e\x77\x61\x74\x74 |
2024/03/03 15:02:46 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:02:46 | stdout | \x39\x46\x68\x6e\x1c\x61\x74\x76\x52\x62\xd7\x67\x84\x74\x74\x47\x72\x6f\x77 |
2024/03/03 15:02:46 | stdout | \x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x70\x90\x75 |
2024/03/03 15:02:46 | stdout | \x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47 |
2024/03/03 15:02:46 | stdout | \x74\x74\x43\x1e\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f |
2024/03/03 15:02:46 | stdout | \x47\x7f\xdd\x77\x08\x26\x31\x47\x72\x6f\x4e\x61\x74\x77\x3f\x72\x6f\x77\x24 |
2024/03/03 15:02:46 | stdout | \x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x06\x74 |
2024/03/03 15:02:46 | stdout | \x11\x67\xe4\x4e\x2a\x6f\x66\x61\x74\x79\x69\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:02:46 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x7a |
2024/03/03 15:02:46 | stdout | \x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74 |
2024/03/03 15:02:46 | stdout | \x77\x69\x74\x74\x41\xb9\x6f\x76\x11\xd4\x7d\xfa\x75\x87\x7f\xc0\x74\x8e\x47 |
2024/03/03 15:02:46 | stdout | \x74\x74\x3b\x72\x6a\x77\x61\x78\x68\x41\xe0\x6f\x7f\x61\x74\x71\x2a\x75\xad |
2024/03/03 15:02:46 | stdout | \x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x79\x77\x77\x49\x4b\x66\x74\x61 |
2024/03/03 15:02:46 | stdout | \x20\x22\x22\x20\x37\x0d\x3f\x5f\x45\x53\x74\x74\x47\x72\x6f\x77\x61\x74\x74 |
2024/03/03 15:02:46 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:02:46 | stdout | \x00\x02\x00\x06\x03\x3f\x01\x50\x0d\x22\x2c\x4f\x22\x38\x27\x77\x26\x25\x77 |
2024/03/03 15:02:46 | stdout | - Growatt original Data: |
2024/03/03 15:02:46 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:46 | stdout | - Growatt packet received: |
2024/03/03 15:02:46 | stdout | |
2024/03/03 15:02:46 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:46 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:46 | stdout | - Growatt packet received: |
2024/03/03 15:02:46 | stdout | |
2024/03/03 15:02:42 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:42 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:42 | stdout | - Growatt packet received: |
2024/03/03 15:02:42 | stdout | |
2024/03/03 15:02:42 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:42 | stdout | <socket.socket fd=5, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 5279), raddr=('192.168.1.191', 44480)> |
2024/03/03 15:02:42 | stdout | - Growatt packet received: |
2024/03/03 15:02:42 | stdout | |
2024/03/03 15:02:41 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:41 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:41 | stdout | - Growatt packet received: |
2024/03/03 15:02:41 | stdout | |
2024/03/03 15:02:41 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:41 | stdout | <socket.socket fd=5, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 5279), raddr=('192.168.1.191', 44480)> |
2024/03/03 15:02:41 | stdout | - Growatt packet received: |
2024/03/03 15:02:41 | stdout | |
2024/03/03 15:02:41 | stdout | - Grott extension processing disabled |
2024/03/03 15:02:41 | stdout | - Grott Send data to Influx disabled |
2024/03/03 15:02:41 | stdout | - Grott Send data to PVOutput disabled |
2024/03/03 15:02:41 | stdout | - MQTT message message sent |
2024/03/03 15:02:41 | stdout | - Grott MQTT topic used : energy/growatt |
2024/03/03 15:02:41 | stdout | "pvtemperature": 335, "pvipmtemperature": 533}} |
2024/03/03 15:02:41 | stdout | "epv1today": 3508, "epv1total": 6902989, "epv2today": 58, "epv2total": 889, |
2024/03/03 15:02:41 | stdout | "totworktime": 0, "pvenergytoday": 0, "pvenergytotal": 0, "epvtotal": 116, |
2024/03/03 15:02:41 | stdout | 0, "pvgridvoltage3": 0, "pvgridcurrent3": 0, "pvgridpower3": 2186548095, |
2024/03/03 15:02:41 | stdout | "pvgridpower": 0, "pvgridvoltage2": 0, "pvgridcurrent2": 0, "pvgridpower2": |
2024/03/03 15:02:41 | stdout | "pvpowerout": 0, "pvfrequentie": 0, "pvgridvoltage": 0, "pvgridcurrent": 0, |
2024/03/03 15:02:41 | stdout | "pv1watt": 16386, "pv2voltage": 2089, "pv2current": 95, "pv2watt": 20049, |
2024/03/03 15:02:41 | stdout | "pvstatus": 5, "pvpowerin": 36400, "pv1voltage": 1775, "pv1current": 92, |
2024/03/03 15:02:41 | stdout | "values": {"datalogserial": "JPC8CLS0TJ", "pvserial": "OUCTCJM022", |
2024/03/03 15:02:41 | stdout | {"device": "OUCTCJM022", "time": "2024-03-03T15:02:39", "buffered": "no", |
2024/03/03 15:02:41 | stdout | - MQTT jsonmsg: |
2024/03/03 15:02:41 | stdout | - pvipmtemperature : 53.3 |
2024/03/03 15:02:41 | stdout | - pvtemperature : 33.5 |
2024/03/03 15:02:41 | stdout | - epv2total : 88.9 |
2024/03/03 15:02:41 | stdout | - epv2today : 5.8 |
2024/03/03 15:02:41 | stdout | - epv1total : 690298.9 |
2024/03/03 15:02:41 | stdout | - epv1today : 350.8 |
2024/03/03 15:02:41 | stdout | - epvtotal : 11.6 |
2024/03/03 15:02:41 | stdout | - pvenergytotal : 0.0 |
2024/03/03 15:02:41 | stdout | - pvenergytoday : 0.0 |
2024/03/03 15:02:41 | stdout | - totworktime : 0.0 |
2024/03/03 15:02:41 | stdout | - pvgridpower3 : 218654809.5 |
2024/03/03 15:02:41 | stdout | - pvgridcurrent3 : 0.0 |
2024/03/03 15:02:41 | stdout | - pvgridvoltage3 : 0.0 |
2024/03/03 15:02:41 | stdout | - pvgridpower2 : 0.0 |
2024/03/03 15:02:41 | stdout | - pvgridcurrent2 : 0.0 |
2024/03/03 15:02:41 | stdout | - pvgridvoltage2 : 0.0 |
2024/03/03 15:02:41 | stdout | - pvgridpower : 0.0 |
2024/03/03 15:02:41 | stdout | - pvgridcurrent : 0.0 |
2024/03/03 15:02:41 | stdout | - pvgridvoltage : 0.0 |
2024/03/03 15:02:41 | stdout | - pvfrequentie : 0.0 |
2024/03/03 15:02:41 | stdout | - pvpowerout : 0.0 |
2024/03/03 15:02:41 | stdout | - pv2watt : 2004.9 |
2024/03/03 15:02:41 | stdout | - pv2current : 9.5 |
2024/03/03 15:02:41 | stdout | - pv2voltage : 208.9 |
2024/03/03 15:02:41 | stdout | - pv1watt : 1638.6 |
2024/03/03 15:02:41 | stdout | - pv1current : 9.2 |
2024/03/03 15:02:41 | stdout | - pv1voltage : 177.5 |
2024/03/03 15:02:41 | stdout | - pvpowerin : 3640.0 |
2024/03/03 15:02:41 | stdout | - pvstatus : 5 |
2024/03/03 15:02:41 | stdout | - pvserial : OUCTCJM022 |
2024/03/03 15:02:41 | stdout | - datalogserial : JPC8CLS0TJ |
2024/03/03 15:02:41 | stdout | - Grott values retrieved: |
2024/03/03 15:02:41 | stdout | - date-time: 2024-03-03T15:02:39 |
2024/03/03 15:02:41 | stdout | - Grott data record date/time processing started |
2024/03/03 15:02:41 | stdout | |
2024/03/03 15:02:41 | stdout | - record layout : T06NNNNX |
2024/03/03 15:02:41 | stdout | - offset : 6 |
2024/03/03 15:02:41 | stdout | - decrypt : True |
2024/03/03 15:02:41 | stdout | - Growatt new layout processing |
2024/03/03 15:02:41 | stdout | - Inverter serial not recognised - using inverter type default |
2024/03/03 15:02:41 | stdout | - Possible Inverter serial OUCTCJM022 |
2024/03/03 15:02:41 | stdout | 0000000000000000000000000000000000000000000000000000000001a03 |
2024/03/03 15:02:41 | stdout | 0000c300400000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:41 | stdout | 000000000010cfb0cf800030030002000010055004e0005000200000063006300000000000000 |
2024/03/03 15:02:41 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:41 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:41 | stdout | 000f520000002400000c3200008e94000012c0000000800001000002d200010000034f0000000 |
2024/03/03 15:02:41 | stdout | 00000000000046504e100230000091b0000000004270000000000000000000000000000008100 |
2024/03/03 15:02:41 | stdout | 000000004150415000000cfb0cf700030e420cfb0cfa0cf90cf90cfb0cfb0cf80cf8000000000 |
2024/03/03 15:02:41 | stdout | 100000000006314be00000008000044d4451000000003001b0064163000000000000000000000 |
2024/03/03 15:02:41 | stdout | 00000000000000000000000000000000000000000000000000000000000000000003e80000012 |
2024/03/03 15:02:41 | stdout | 02800000b1b0000005c00000338000000090000097d0000002600000a550000002f00000efd00 |
2024/03/03 15:02:41 | stdout | 000000000000000079cd000014b40000000000000000000014b40000000800050bc731ce00000 |
2024/03/03 15:02:41 | stdout | 00000010000000000000000000213006300000000000000000000000000000000000079cd0000 |
2024/03/03 15:02:41 | stdout | 00091b00000000000000010000000000000000000003e80464000500000000000000000000000 |
2024/03/03 15:02:41 | stdout | 1720000021510b810e40000000000000000000000000000000000000000000000000000002300 |
2024/03/03 15:02:41 | stdout | 000000000000000000000000000000000000000000000000000000000000000007f2014f01110 |
2024/03/03 15:02:41 | stdout | 4006954cd0000003a00000379000000460000046d000000000000000000000000000000000000 |
2024/03/03 15:02:41 | stdout | 7f0966008a0000828d000000000000000000000000000000000000000000000000007400000db |
2024/03/03 15:02:41 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000825413 |
2024/03/03 15:02:41 | stdout | 007c000500008e3006ef005c000040020829005f00004e51000170a009bd07e708a200fa00000 |
2024/03/03 15:02:41 | stdout | f554354434a4d30323200000000000000000000000000000000000000001803030f0227030000 |
2024/03/03 15:02:41 | stdout | 00150006033f01044a504338434c5330544a00000000000000000000000000000000000000004 |
2024/03/03 15:02:41 | stdout | - Growatt plain data: |
2024/03/03 15:02:41 | stdout | - Grott Growatt data decrypted |
2024/03/03 15:02:41 | stdout | - Growatt data decrypted V2 |
2024/03/03 15:02:41 | stdout | - Record layout used : T06NNNNX |
2024/03/03 15:02:41 | stdout | - no matching record layout found, try generic |
2024/03/03 15:02:41 | stdout | - layout : T060104X |
2024/03/03 15:02:41 | stdout | - Grott data record length 839 |
2024/03/03 15:02:41 | stdout | - Grott automatic protocol detection |
2024/03/03 15:02:41 | stdout | \x6f\x6d\x62 |
2024/03/03 15:02:41 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:02:41 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77 |
2024/03/03 15:02:41 | stdout | \x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74 |
2024/03/03 15:02:41 | stdout | \x14\x61\x17\x74\x47\x72\x6f\x77\x61\x74\x74\x47\xb1\x6f\x37\x61\x74\x74\x47 |
2024/03/03 15:02:41 | stdout | \x74\x77\x47\x42\x6f\x57\x61\x75\x74\x12\x72\x21\x77\x64\x74\x76\x47\x72\x6f |
2024/03/03 15:02:41 | stdout | \x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x46\x7e\x94\x7b\x99 |
2024/03/03 15:02:41 | stdout | \x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74 |
2024/03/03 15:02:41 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:02:41 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77 |
2024/03/03 15:02:41 | stdout | \x73\x6f\x77\x62\x3b\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74 |
2024/03/03 15:02:41 | stdout | \x77\x61\xfa\xe0\x47\x72\x7d\xb7\x61\x74\x74\xc7\x72\x6e\x77\x61\x76\xa6\x47 |
2024/03/03 15:02:41 | stdout | \x74\x74\x47\x72\x6f\x77\xe0\x74\x74\x48\x20\x6f\x77\x61\x50\x74\x47\x7e\x5d |
2024/03/03 15:02:41 | stdout | \x47\x72\x66\x6c\x61\x74\x74\x47\x76\x48\x77\x61\x74\x74\x47\x72\x6f\x77\x61 |
2024/03/03 15:02:41 | stdout | \x97\x7b\x99\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x76\x0a\x73\x80\x74\x57 |
2024/03/03 15:02:41 | stdout | \x6d\x83\x74\x44\x7c\x2d\x7b\x9a\x78\x8e\x4b\x8b\x63\x8e\x6d\x8f\x78\xbc\x7e |
2024/03/03 15:02:41 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x36\x31\x35\x24\x47\x72\x63\x8c |
2024/03/03 15:02:41 | stdout | \x72\x6f\x33\xb5\x31\x64\x47\x72\x6f\x74\x61\x6f\x74\x23\x64\x5f\x77\x61\x74 |
2024/03/03 15:02:41 | stdout | \x77\x62\x9c\x74\x47\x73\x4e\x77\x61\x74\x74\x47\x11\x7b\xc9\x61\x74\x74\x4f |
2024/03/03 15:02:41 | stdout | \x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f |
2024/03/03 15:02:41 | stdout | \x68\x72\x6f\x79\x9c\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61 |
2024/03/03 15:02:41 | stdout | \x6f\x77\x61\x7d\x74\x47\x7b\x12\x77\x61\x74\x52\x47\x72\x65\x22\x61\x74\x74 |
2024/03/03 15:02:41 | stdout | \xa6\x45\xba\x47\x72\x6f\x5f\x61\x74\x7f\x5c\x72\x6f\x77\x3d\x74\x74\x44\x4a |
2024/03/03 15:02:41 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x7b\xc3\x61\x74\x74\x4f\x72\x6a\x7c |
2024/03/03 15:02:41 | stdout | \x72\x16\xba\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x3e\xbf\x6f\x77\x75\xc0 |
2024/03/03 15:02:41 | stdout | \x77\x02\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47 |
2024/03/03 15:02:41 | stdout | \x74\x74\x47\x72\x6f\x77\x61\x75\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x70\x7c |
2024/03/03 15:02:41 | stdout | \x47\x72\x6f\x77\x61\x74\x77\xaf\x76\x0b\x77\x64\x74\x74\x47\x72\x6f\x77\x61 |
2024/03/03 15:02:41 | stdout | \x6f\x77\x42\x74\x74\x4e\x69\x6f\x77\x61\x74\x74\x47\x72\x6e\x77\x61\x74\x74 |
2024/03/03 15:02:41 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:02:41 | stdout | \x3b\x46\x63\x6e\x05\x61\x74\x76\x52\x62\xd7\x67\x85\x74\x74\x47\x72\x6f\x77 |
2024/03/03 15:02:41 | stdout | \x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x70\x93\x75 |
2024/03/03 15:02:41 | stdout | \x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47 |
2024/03/03 15:02:41 | stdout | \x74\x74\x43\x1f\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f |
2024/03/03 15:02:41 | stdout | \x47\x7f\xdb\x77\x08\x20\xb9\x47\x72\x6f\x4d\x61\x74\x77\x3e\x72\x6f\x77\x27 |
2024/03/03 15:02:41 | stdout | \x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x00\x74 |
2024/03/03 15:02:41 | stdout | \x35\x67\x0b\x4e\x14\x6f\xfd\x61\x74\xf6\xca\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:02:41 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\xf5 |
2024/03/03 15:02:41 | stdout | \x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74 |
2024/03/03 15:02:41 | stdout | \x77\x3e\x74\x74\x09\x23\x6f\x76\x11\xd4\x7d\xfa\x75\x88\x7f\xc3\x74\x8e\x47 |
2024/03/03 15:02:41 | stdout | \x74\x74\x3b\x72\x6a\x77\x61\xfa\x44\x41\x9d\x6f\x2b\x61\x74\x34\x45\x7a\x46 |
2024/03/03 15:02:41 | stdout | \x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x79\x77\x77\x48\x70\x48\x74\x61 |
2024/03/03 15:02:41 | stdout | \x20\x22\x22\x20\x37\x0d\x3f\x5f\x45\x53\x74\x74\x47\x72\x6f\x77\x61\x74\x74 |
2024/03/03 15:02:41 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:02:41 | stdout | \x00\x15\x00\x06\x03\x3f\x01\x04\x0d\x22\x2c\x4f\x22\x38\x27\x77\x26\x25\x77 |
2024/03/03 15:02:41 | stdout | - Growatt original Data: |
2024/03/03 15:02:41 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:41 | stdout | - Growatt packet received: |
2024/03/03 15:02:41 | stdout | |
2024/03/03 15:02:39 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:39 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:39 | stdout | - Growatt packet received: |
2024/03/03 15:02:39 | stdout | |
2024/03/03 15:02:38 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:38 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:38 | stdout | - Growatt packet received: |
2024/03/03 15:02:38 | stdout | |
2024/03/03 15:02:37 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:37 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:37 | stdout | - Growatt packet received: |
2024/03/03 15:02:37 | stdout | |
2024/03/03 15:02:36 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:36 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:36 | stdout | - Growatt packet received: |
2024/03/03 15:02:36 | stdout | |
2024/03/03 15:02:35 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:35 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:35 | stdout | - Growatt packet received: |
2024/03/03 15:02:35 | stdout | |
2024/03/03 15:02:34 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:34 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:34 | stdout | - Growatt packet received: |
2024/03/03 15:02:34 | stdout | |
2024/03/03 15:02:33 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:33 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:33 | stdout | - Growatt packet received: |
2024/03/03 15:02:33 | stdout | |
2024/03/03 15:02:32 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:32 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:32 | stdout | - Growatt packet received: |
2024/03/03 15:02:32 | stdout | |
2024/03/03 15:02:31 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:31 | stdout | <socket.socket fd=5, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 5279), raddr=('192.168.1.191', 44480)> |
2024/03/03 15:02:31 | stdout | - Growatt packet received: |
2024/03/03 15:02:31 | stdout | |
2024/03/03 15:02:31 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:31 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:31 | stdout | - Growatt packet received: |
2024/03/03 15:02:31 | stdout | |
2024/03/03 15:02:30 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:30 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:30 | stdout | - Growatt packet received: |
2024/03/03 15:02:30 | stdout | |
2024/03/03 15:02:28 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:28 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:28 | stdout | - Growatt packet received: |
2024/03/03 15:02:28 | stdout | |
2024/03/03 15:02:28 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:28 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:28 | stdout | - Growatt packet received: |
2024/03/03 15:02:27 | stdout | |
2024/03/03 15:02:26 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:26 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:26 | stdout | - Growatt packet received: |
2024/03/03 15:02:26 | stdout | |
2024/03/03 15:02:25 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:25 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:25 | stdout | - Growatt packet received: |
2024/03/03 15:02:25 | stdout | |
2024/03/03 15:02:25 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:25 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:25 | stdout | - Growatt packet received: |
2024/03/03 15:02:25 | stdout | |
2024/03/03 15:02:25 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:25 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:25 | stdout | - Growatt packet received: |
2024/03/03 15:02:25 | stdout | |
2024/03/03 15:02:25 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:25 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:25 | stdout | - Growatt packet received: |
2024/03/03 15:02:25 | stdout | |
2024/03/03 15:02:25 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:25 | stdout | <socket.socket fd=5, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 5279), raddr=('192.168.1.191', 44480)> |
2024/03/03 15:02:25 | stdout | - Growatt packet received: |
2024/03/03 15:02:25 | stdout | |
2024/03/03 15:02:25 | stdout | - Grott data ack record or data record not defined no processing done |
2024/03/03 15:02:25 | stdout | 0000000000000000000000000000000000000000000000000000000006327 |
2024/03/03 15:02:25 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:25 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:25 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:25 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:25 | stdout | 33454447504b30323139353233323737423038000000000000000000000000000000000000000 |
2024/03/03 15:02:25 | stdout | 00000000000046504e147504b3032313935323332373741464647504b30323139353233323737 |
2024/03/03 15:02:25 | stdout | 000000000001000000000001000a0000000000000000000000000000000000000001000000000 |
2024/03/03 15:02:25 | stdout | 00000000000000000000000000064006400010000000000000000000000000000001e041e0001 |
2024/03/03 15:02:25 | stdout | 00000000000000000000000064000500000000000000000000000000000000000000000000000 |
2024/03/03 15:02:25 | stdout | 06400640000000100000001000000010000000100000000000000000000000000000000000000 |
2024/03/03 15:02:25 | stdout | 00000000000000000000000000000000000000000000000000000005000000640000000100000 |
2024/03/03 15:02:25 | stdout | 016a870a0044c02bc044c02580000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:25 | stdout | ff4e2000ff4e20000000000000000000000000000003e804641770000012c0003201d6023f12c |
2024/03/03 15:02:25 | stdout | 816084400140005096f08fc0000000000000000000000000096000001e400ff4e2000ff4e2000 |
2024/03/03 15:02:25 | stdout | 000000000000000009c4000052414141323132303036000001310000000013b0001809e209b40 |
2024/03/03 15:02:25 | stdout | 00ab1125c1450000000000000000007d10a3e128e1450007f0034007f001b03ea0019001b001b |
2024/03/03 15:02:25 | stdout | 456e6572677920202000010dad000007e800030003000f0003000e000007300a3e128e1450073 |
2024/03/03 15:02:25 | stdout | 01e004100c8006400004f554354434a4d3032320100f2650001005a000000002020204e657720 |
2024/03/03 15:02:25 | stdout | 007c000108000000006400642710000013880e105241312e30205a43424100060001000005dc0 |
2024/03/03 15:02:25 | stdout | f554354434a4d30323200000000000000000000000000000000000000001803030f020e030000 |
2024/03/03 15:02:25 | stdout | 00030006033f01034a504338434c5330544a00000000000000000000000000000000000000004 |
2024/03/03 15:02:25 | stdout | - Growatt plain data: |
2024/03/03 15:02:25 | stdout | - Grott Growatt data decrypted |
2024/03/03 15:02:25 | stdout | - Growatt data decrypted V2 |
2024/03/03 15:02:25 | stdout | - Record layout used : T060103X |
2024/03/03 15:02:25 | stdout | - no matching record layout found, try generic |
2024/03/03 15:02:25 | stdout | - layout : T060103X |
2024/03/03 15:02:25 | stdout | - Grott data record length 839 |
2024/03/03 15:02:25 | stdout | - Grott automatic protocol detection |
2024/03/03 15:02:25 | stdout | \x6f\x14\x46 |
2024/03/03 15:02:25 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:02:25 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77 |
2024/03/03 15:02:25 | stdout | \x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74 |
2024/03/03 15:02:25 | stdout | \x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47 |
2024/03/03 15:02:25 | stdout | \x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f |
2024/03/03 15:02:25 | stdout | \x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61 |
2024/03/03 15:02:25 | stdout | \x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74 |
2024/03/03 15:02:25 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:02:25 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77 |
2024/03/03 15:02:25 | stdout | \x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74 |
2024/03/03 15:02:25 | stdout | \x45\x52\x46\x43\x70\x30\x5f\x4f\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47 |
2024/03/03 15:02:25 | stdout | \x45\x4d\x72\x40\x5c\x45\x56\x43\x47\x02\x36\x28\x27\x2a\x44\x46\x76\x4b\x5a |
2024/03/03 15:02:25 | stdout | \x0c\x42\x5d\x46\x58\x41\x46\x74\x40\x58\x40\x20\x32\x32\x00\x22\x24\x47\x53 |
2024/03/03 15:02:25 | stdout | \x6f\x77\x60\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x76\x0a\x73\x80\x33\x24 |
2024/03/03 15:02:25 | stdout | \x61\x7e\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:02:25 | stdout | \x74\x47\x6c\x6b\x69\x61\x75\x74\x47\x72\x6f\x77\x60\x74\x74\x47\x72\x6f\x76 |
2024/03/03 15:02:25 | stdout | \x72\x0b\x77\x05\x74\x75\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74 |
2024/03/03 15:02:25 | stdout | \x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47 |
2024/03/03 15:02:25 | stdout | \x74\x71\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f |
2024/03/03 15:02:25 | stdout | \x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x05 |
2024/03/03 15:02:25 | stdout | \x6f\x76\x61\x74\x74\x46\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74 |
2024/03/03 15:02:25 | stdout | \x61\x74\x75\x47\x72\x6f\x13\x61\x10\x74\x47\x72\x6e\x77\x61\x74\x75\x47\x72 |
2024/03/03 15:02:25 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x71\x74\x47\x72\x0b\x77 |
2024/03/03 15:02:25 | stdout | \x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74 |
2024/03/03 15:02:25 | stdout | \x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47 |
2024/03/03 15:02:25 | stdout | \xa2\x76\x78\x60\xaf\x61\xc9\x04\xd4\x43\x3e\x6d\xcb\x65\x38\x76\x1f\x72\x6f |
2024/03/03 15:02:25 | stdout | \x47\x72\x6f\x77\x61\x74\x77\xaf\x76\x0b\x60\x11\x74\x74\x55\xb2\x6f\x45\x60 |
2024/03/03 15:02:25 | stdout | \x90\x39\x41\x74\x8b\x09\x52\x6f\x88\x2f\x54\x74\x47\x72\x6f\x77\x61\x74\x74 |
2024/03/03 15:02:25 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\xe2\x47\x72\x6e\x93\x61\x8b\x3a\x67\x72 |
2024/03/03 15:02:25 | stdout | \x96\x4e\xc6\x67\x61\x69\x30\x74\x53\x72\x6a\x7e\x0e\x7c\x88\x47\x72\x6f\x77 |
2024/03/03 15:02:25 | stdout | \x40\x5e\x45\x51\x44\x42\x47\x72\x6e\x46\x61\x74\x74\x47\x61\xdf\x77\x79\x7d |
2024/03/03 15:02:25 | stdout | \x6c\x61\x6f\x74\x47\x72\x6f\x77\x61\x74\x74\x4e\xb6\x6f\x77\x33\x35\x35\x06 |
2024/03/03 15:02:25 | stdout | \x7e\x4a\x55\xfc\x7b\x27\x61\x0b\x74\x73\x72\x10\x77\x7a\x77\x9e\x47\x6b\x6f |
2024/03/03 15:02:25 | stdout | \x17\x75\x5f\x7d\xd0\x66\x28\x53\x22\x6f\x77\x61\x74\x74\x47\x72\x6f\x70\xb0 |
2024/03/03 15:02:25 | stdout | \x6f\x74\x61\x77\x74\x48\x72\x6c\x77\x6f\x74\x74\x40\x42\x65\x49\x73\xfa\x60 |
2024/03/03 15:02:25 | stdout | \x16\x54\x31\x29\x17\x1d\x10\x18\x54\x54\x67\x72\x6e\x7a\xcc\x74\x74\x40\x9a |
2024/03/03 15:02:25 | stdout | \x46\x75\x73\x6f\x85\x04\x74\x75\x47\x28\x6f\x77\x61\x74\x54\x67\x52\x21\x12 |
2024/03/03 15:02:25 | stdout | \xae\x6f\x69\x61\x35\x74\x8f\x72\x0b\x77\x61\x3b\x21\x04\x26\x2c\x3d\x2c\x44 |
2024/03/03 15:02:25 | stdout | \x79\x71\x26\x35\x76\x5c\x5f\x57\x3b\x37\x36\x06\x72\x69\x77\x60\x74\x74\x42 |
2024/03/03 15:02:25 | stdout | \x74\x74\x3b\x72\x6e\x7f\x61\x74\x74\x47\x16\x6f\x13\x46\x64\x74\x47\x61\xe7 |
2024/03/03 15:02:25 | stdout | \x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x79\x77\x77\x48\x70\x61\x74\x61 |
2024/03/03 15:02:25 | stdout | \x20\x22\x22\x20\x37\x0d\x3f\x5f\x45\x53\x74\x74\x47\x72\x6f\x77\x61\x74\x74 |
2024/03/03 15:02:25 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:02:25 | stdout | \x00\x03\x00\x06\x03\x3f\x01\x03\x0d\x22\x2c\x4f\x22\x38\x27\x77\x26\x25\x77 |
2024/03/03 15:02:25 | stdout | - Growatt original Data: |
2024/03/03 15:02:25 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:25 | stdout | - Growatt packet received: |
2024/03/03 15:02:25 | stdout | |
2024/03/03 15:02:25 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:25 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:25 | stdout | - Growatt packet received: |
2024/03/03 15:02:25 | stdout | |
2024/03/03 15:02:25 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:25 | stdout | <socket.socket fd=5, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 5279), raddr=('192.168.1.191', 44480)> |
2024/03/03 15:02:25 | stdout | - Growatt packet received: |
2024/03/03 15:02:21 | stdout | |
2024/03/03 15:02:21 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:21 | stdout | <socket.socket fd=5, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 5279), raddr=('192.168.1.191', 44480)> |
2024/03/03 15:02:21 | stdout | - Growatt packet received: |
2024/03/03 15:02:21 | stdout | |
2024/03/03 15:02:20 | stdout | - Data less then minimum record length, data not processed |
2024/03/03 15:02:20 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:20 | stdout | - Growatt packet received: |
2024/03/03 15:02:20 | stdout | |
2024/03/03 15:02:15 | stdout | - Grott data ack record or data record not defined no processing done |
2024/03/03 15:02:15 | stdout | 00000000000f158 |
2024/03/03 15:02:15 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:15 | stdout | 0097d00000000000108760213000000000063006400004510000044d400500054000000000000 |
2024/03/03 15:02:15 | stdout | 000000000000000000000000000000000000000000000000000000002600000a5500000009000 |
2024/03/03 15:02:15 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:15 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:15 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:15 | stdout | 6c000000000000000000000000000000000000000079957a11000000000000000000000000000 |
2024/03/03 15:02:15 | stdout | 00000000000000000000000829200000caf00001381096000000000008b00000000ffff824601 |
2024/03/03 15:02:15 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:15 | stdout | 0000000008f5c0000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:15 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:15 | stdout | 00000000000000000000000000000000000000000000000000000000000000000000000000000 |
2024/03/03 15:02:15 | stdout | 7994000500000000000000000000000000000000000006da005e0829006000000000000000000 |
2024/03/03 15:02:15 | stdout | f554354434a4d30323200000000000000000000000000000000000000001803030f020e027918 |
2024/03/03 15:02:15 | stdout | 004c0006024101364a504338434c5330544a00000000000000000000000000000000000000004 |
2024/03/03 15:02:15 | stdout | - Growatt plain data: |
2024/03/03 15:02:15 | stdout | - Grott Growatt data decrypted |
2024/03/03 15:02:15 | stdout | - Growatt data decrypted V2 |
2024/03/03 15:02:15 | stdout | - Record layout used : T060136X |
2024/03/03 15:02:15 | stdout | - no matching record layout found, try generic |
2024/03/03 15:02:15 | stdout | - layout : T060136X |
2024/03/03 15:02:15 | stdout | - Grott data record length 585 |
2024/03/03 15:02:15 | stdout | - Grott automatic protocol detection |
2024/03/03 15:02:15 | stdout | \x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x83\x37 |
2024/03/03 15:02:15 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:02:15 | stdout | \x20\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77 |
2024/03/03 15:02:15 | stdout | \x72\x6f\x77\x61\x74\x17\x47\x16\x6f\x77\x24\x64\x74\x47\x36\xbb\x77\x31\x74 |
2024/03/03 15:02:15 | stdout | \x22\x61\x74\x74\x4e\x72\x6f\x7e\x1c\x74\x74\x47\x72\x6f\x76\x69\x02\x76\x54 |
2024/03/03 15:02:15 | stdout | \x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x52\x47\x72\x65 |
2024/03/03 15:02:15 | stdout | \x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61 |
2024/03/03 15:02:15 | stdout | \x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74 |
2024/03/03 15:02:15 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:02:15 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77 |
2024/03/03 15:02:15 | stdout | \x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74 |
2024/03/03 15:02:15 | stdout | \x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47 |
2024/03/03 15:02:15 | stdout | \x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f |
2024/03/03 15:02:15 | stdout | \x47\x72\x6f\x77\x61\x74\x0d\xd2\x08\x7e\x77\x61\x74\x74\x47\x72\x6f\x77\x61 |
2024/03/03 15:02:15 | stdout | \x90\xf5\x27\x75\x18\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74 |
2024/03/03 15:02:15 | stdout | \x6d\xdb\x74\x47\x61\xee\x7e\x01\x74\x74\x47\x72\x6f\xfc\x61\x74\x74\x47\x8d |
2024/03/03 15:02:15 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\xc5\xe0\x6f\x77 |
2024/03/03 15:02:15 | stdout | \x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74 |
2024/03/03 15:02:15 | stdout | \x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47 |
2024/03/03 15:02:15 | stdout | \x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f |
2024/03/03 15:02:15 | stdout | \x47\x72\x6f\x77\x61\x74\x74\xc8\x2e\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61 |
2024/03/03 15:02:15 | stdout | \x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74 |
2024/03/03 15:02:15 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:02:15 | stdout | \x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77 |
2024/03/03 15:02:15 | stdout | \x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74 |
2024/03/03 15:02:15 | stdout | \x77\x61\x74\x74\x41\xa8\x6f\x29\x69\x5d\x74\x27\x72\x6f\x77\x61\x74\x74\x47 |
2024/03/03 15:02:15 | stdout | \x6c\x0d\xd3\x72\x6a\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f |
2024/03/03 15:02:15 | stdout | \x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x79\x77\x77\x48\x70\x61\x75\x18 |
2024/03/03 15:02:15 | stdout | \x20\x22\x22\x20\x37\x0d\x3f\x5f\x45\x53\x74\x74\x47\x72\x6f\x77\x61\x74\x74 |
2024/03/03 15:02:15 | stdout | \x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72\x6f\x77\x61\x74\x74\x47\x72 |
2024/03/03 15:02:15 | stdout | \x00\x4c\x00\x06\x02\x41\x01\x36\x0d\x22\x2c\x4f\x22\x38\x27\x77\x26\x25\x77 |
2024/03/03 15:02:15 | stdout | - Growatt original Data: |
2024/03/03 15:02:15 | stdout | <socket.socket fd=4, family=AddressFamily.AF_INET, type=SocketKind.SOCK_STREAM, proto=0, laddr=('192.168.1.244', 36322), raddr=('47.91.67.66', 5279)> |
2024/03/03 15:02:15 | stdout | - Growatt packet received: |
2024/03/03 15:02:15 | stdout | |
2024/03/03 15:02:15 | stdout | - ('192.168.1.191', 44480) has connected |
2024/03/03 15:02:13 | stdout | IP and port information not available |
2024/03/03 15:02:13 | stdout | Hostname : ledidobe-grott-1 |
2024/03/03 15:02:13 | stdout | Grott proxy mode started |
2024/03/03 15:02:13 | stdout | |
2024/03/03 15:02:13 | stdout | |
2024/03/03 15:02:13 | stdout | extvar: {'none': 'none'} |
2024/03/03 15:02:13 | stdout | extname: grottext |
2024/03/03 15:02:13 | stdout | extension: False |
2024/03/03 15:02:13 | stdout | _Extension: |
2024/03/03 15:02:13 | stdout | token: secret |
2024/03/03 15:02:13 | stdout | bucket: grottdb |
2024/03/03 15:02:13 | stdout | organization: grottorg |
2024/03/03 15:02:13 | stdout | password: secret |
2024/03/03 15:02:13 | stdout | user: grott |
2024/03/03 15:02:13 | stdout | port: 8086 |
2024/03/03 15:02:13 | stdout | ip: localhost |
2024/03/03 15:02:13 | stdout | database: grottdb |
2024/03/03 15:02:13 | stdout | influx2: False |
2024/03/03 15:02:13 | stdout | influx: False |
2024/03/03 15:02:13 | stdout | _Influxdb: |
2024/03/03 15:02:13 | stdout | pvsystemid: systemid1 |
2024/03/03 15:02:13 | stdout | pvinverters: 1 |
2024/03/03 15:02:13 | stdout | pvapikey: yourapikey |
2024/03/03 15:02:13 | stdout | pvurl: https://pvoutput.org/service/r2/addstatus.jsp |
2024/03/03 15:02:13 | stdout | pvtemp: False |
2024/03/03 15:02:13 | stdout | pvdisv1: False |
2024/03/03 15:02:13 | stdout | pvoutput: False |
2024/03/03 15:02:13 | stdout | _PVOutput: |
2024/03/03 15:02:13 | stdout | growattport: 5279 |
2024/03/03 15:02:13 | stdout | growattip: 47.91.67.66 |
2024/03/03 15:02:13 | stdout | _Growatt server: |
2024/03/03 15:02:13 | stdout | mqttpsw: secret |
2024/03/03 15:02:13 | stdout | mqttuser: grott |
2024/03/03 15:02:13 | stdout | mqtttauth: False |
2024/03/03 15:02:13 | stdout | mqtttretain: False |
2024/03/03 15:02:13 | stdout | mqttinverterintopic: False |
2024/03/03 15:02:13 | stdout | mqttmtopicname: energy/meter |
2024/03/03 15:02:13 | stdout | mqttmtopic: False |
2024/03/03 15:02:13 | stdout | mqtttopic: energy/growatt |
2024/03/03 15:02:13 | stdout | mqttport: 1883 |
2024/03/03 15:02:13 | stdout | mqttip: localhost |
2024/03/03 15:02:13 | stdout | nomqtt False |
2024/03/03 15:02:13 | stdout | _MQTT: |
2024/03/03 15:02:13 | stdout | grottport 5279 |
2024/03/03 15:02:13 | stdout | grottip default |
2024/03/03 15:02:13 | stdout | mode: proxy |
2024/03/03 15:02:13 | stdout | inverterid: automatic |
2024/03/03 15:02:13 | stdout | offset: 6 |
2024/03/03 15:02:13 | stdout | valueoffset: 6 |
2024/03/03 15:02:13 | stdout | timezone: local |
2024/03/03 15:02:13 | stdout | sendbuf: True |
2024/03/03 15:02:13 | stdout | time: auto |
2024/03/03 15:02:13 | stdout | noipf: False |
2024/03/03 15:02:13 | stdout | blockcmd: False |
2024/03/03 15:02:13 | stdout | include_all: False |
2024/03/03 15:02:13 | stdout | invtypemap: {} |
2024/03/03 15:02:13 | stdout | invtype: default |
2024/03/03 15:02:13 | stdout | compat: False |
2024/03/03 15:02:13 | stdout | decrypt: True |
2024/03/03 15:02:13 | stdout | minrecl: 100 |
2024/03/03 15:02:13 | stdout | config file: grott.ini |
2024/03/03 15:02:13 | stdout | trace: False |
2024/03/03 15:02:13 | stdout | verbose: True |
2024/03/03 15:02:13 | stdout | version: 2.8.3 |
2024/03/03 15:02:13 | stdout | _Generic: |
2024/03/03 15:02:13 | stdout | |
2024/03/03 15:02:13 | stdout | Grott settings: |
2024/03/03 15:02:13 | stdout | |
2024/03/03 15:02:13 | stdout | Grott records whitelisted : {'5250', '5003', '0116', '0105', '5229', '5119', '5019', '5016', '5116', '5216', '5005', '501b', '5105', '5219', '5104', '0103', '0150', '5150', '5103', '0120', '5050', '5004', '0104', '5129', '0119'} |
2024/03/03 15:02:13 | stdout | |
2024/03/03 15:02:13 | stdout | Grott external record whitelist 'recwl.txt' not found |
2024/03/03 15:02:13 | stdout | |
2024/03/03 15:02:13 | stdout | |
2024/03/03 15:02:13 | stdout | T06NNNNXMIN : |
2024/03/03 15:02:13 | stdout | |
2024/03/03 15:02:13 | stdout | T06NNNNXSPA : |
2024/03/03 15:02:13 | stdout | {'decrypt': {'value': 'True'}, 'datalogserial': {'value': 16, 'length': 10, 'type': 'text', 'incl': 'yes'}, 'pvserial': {'value': 36, 'length': 10, 'type': 'text'}, 'date': {'value': 56, 'divide': 10}, 'recortype1': {'value': 70, 'length': 2, 'type': 'num', 'incl': 'no'}, 'recortype2': {'value': 74, 'length': 2, 'type': 'num', 'incl': 'no'}, 'pvstatus': {'value': 78, 'length': 2, 'type': 'num'}, 'pvpowerin': {'value': 82, 'length': 4, 'type': 'num', 'divide': 10}, 'pv1voltage': {'value': 90, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1current': {'value': 94, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1watt': {'value': 98, 'length': 4, 'type': 'num', 'divide': 10}, 'pv2voltage': {'value': 106, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2current': {'value': 110, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2watt': {'value': 114, 'length': 4, 'type': 'num', 'divide': 10}, 'pvpowerout': {'value': 218, 'length': 4, 'type': 'numx', 'divide': 10}, 'pvfrequentie': {'value': 226, 'length': 2, 'type': 'num', 'divide': 100}, 'pvgridvoltage': {'value': 230, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent': {'value': 234, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower': {'value': 238, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage2': {'value': 246, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent2': {'value': 250, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower2': {'value': 254, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage3': {'value': 262, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent3': {'value': 266, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower3': {'value': 270, 'length': 4, 'type': 'num', 'divide': 10}, 'totworktime': {'value': 306, 'length': 4, 'type': 'num', 'divide': 7200}, 'eactoday': {'value': 290, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytoday': {'value': 290, 'length': 4, 'type': 'num', 'divide': 10}, 'eactotal': {'value': 298, 'length': 4, 'type': 'num', 'divide': 10}, 'epvtotal': {'value': 442, 'length': 4, 'type': 'num', 'divide': 10}, 'epv1today': {'value': 314, 'length': 4, 'type': 'num', 'divide': 10}, 'epv1total': {'value': 322, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2today': {'value': 330, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2total': {'value': 338, 'length': 4, 'type': 'num', 'divide': 10}, 'pvtemperature': {'value': 450, 'length': 2, 'type': 'num', 'divide': 10}, 'pvipmtemperature': {'value': 454, 'length': 2, 'type': 'num', 'divide': 10}, 'pvboosttemp': {'value': 458, 'length': 2, 'type': 'num', 'divide': 10}, 'bat_dsp': {'value': 466, 'length': 2, 'type': 'num', 'divide': 10}, 'pbusvolt': {'value': 470, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, '#nbusvolt': {'value': 474, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, '#ipf': {'value': 478, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, '#realoppercent': {'value': 482, 'length': 2, 'type': 'num', 'divide': 100, 'incl': 'no'}, '#opfullwatt': {'value': 486, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, '#deratingmode': {'value': 494, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'eacharge_today': {'value': 526, 'length': 4, 'type': 'num', 'divide': 10}, 'eacharge_total': {'value': 534, 'length': 4, 'type': 'num', 'divide': 10}, 'batterytype': {'value': 554, 'length': 2, 'type': 'num', 'divide': 1}, 'uwsysworkmode': {'value': 586, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword0': {'value': 590, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword1': {'value': 594, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword2': {'value': 588, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword3': {'value': 602, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword4': {'value': 606, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword5': {'value': 610, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword6': {'value': 614, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword7': {'value': 618, 'length': 2, 'type': 'num', 'divide': 1}, 'pdischarge1': {'value': 622, 'length': 4, 'type': 'num', 'divide': 10}, 'p1charge1': {'value': 630, 'length': 4, 'type': 'num', 'divide': 10}, 'vbat': {'value': 738, 'length': 2, 'type': 'num', 'divide': 10}, 'SOC': {'value': 742, 'length': 2, 'type': 'num', 'divide': 1}, 'pactouserr': {'value': 746, 'length': 4, 'type': 'num', 'divide': 10}, '#pactousers': {'value': 654, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, '#pactousert': {'value': 662, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'pactousertot': {'value': 670, 'length': 4, 'type': 'num', 'divide': 10}, 'pactogridr': {'value': 678, 'length': 4, 'type': 'num', 'divide': 10}, '#pactogrids': {'value': 686, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, '#pactogridt': {'value': 694, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'pactogridtot': {'value': 702, 'length': 4, 'type': 'num', 'divide': 10}, 'plocaloadr': {'value': 710, 'length': 4, 'type': 'num', 'divide': 10}, '#plocaloads': {'value': 718, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, '#plocaloadt': {'value': 726, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'plocaloadtot': {'value': 734, 'length': 4, 'type': 'num', 'divide': 10}, '#ipm': {'value': 742, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, '#battemp': {'value': 746, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'spdspstatus': {'value': 750, 'length': 2, 'type': 'num', 'divide': 10}, 'spbusvolt': {'value': 754, 'length': 2, 'type': 'num', 'divide': 10}, 'etouser_tod': {'value': 762, 'length': 4, 'type': 'num', 'divide': 10}, 'etouser_tot': {'value': 770, 'length': 4, 'type': 'num', 'divide': 10}, 'etogrid_tod': {'value': 778, 'length': 4, 'type': 'num', 'divide': 10}, 'etogrid_tot': {'value': 786, 'length': 4, 'type': 'num', 'divide': 10}, 'edischarge1_tod': {'value': 794, 'length': 4, 'type': 'num', 'divide': 10}, 'edischarge1_tot': {'value': 802, 'length': 4, 'type': 'num', 'divide': 10}, 'eharge1_tod': {'value': 810, 'length': 4, 'type': 'num', 'divide': 10}, 'eharge1_tot': {'value': 818, 'length': 4, 'type': 'num', 'divide': 10}, 'elocalload_tod': {'value': 826, 'length': 4, 'type': 'num', 'divide': 10}, 'elocalload_tot': {'value': 834, 'length': 4, 'type': 'num', 'divide': 10}} |
2024/03/03 15:02:13 | stdout | T05NNNNXSPH : |
2024/03/03 15:02:13 | stdout | {'decrypt': {'value': 'True'}, 'datalogserial': {'value': 16, 'length': 10, 'type': 'text', 'incl': 'yes'}, 'device': {'value': 'SDM630', 'type': 'def', 'incl': 'no'}, 'logstart': {'value': 96, 'type': 'def', 'incl': 'no'}, 'active_energy': {'pos': 1, 'type': 'log'}, 'reactive_energy': {'pos': 2, 'type': 'log'}, 'activePowerL1': {'pos': 3, 'type': 'log'}, 'activePowerL2': {'pos': 4, 'type': 'log'}, 'activePowerL3': {'pos': 5, 'type': 'log'}, 'reactivePowerL1': {'pos': 6, 'type': 'log'}, 'reactivePowerL2': {'pos': 7, 'type': 'log'}, 'reactivePowerL3': {'pos': 8, 'type': 'log'}, 'apperentPowerL1': {'pos': 9, 'type': 'log'}, 'apperentPowerL2': {'pos': 10, 'type': 'log'}, 'apperentPowerL3': {'pos': 11, 'type': 'log'}, 'powerFactorL1': {'pos': 12, 'type': 'log'}, 'powerFactorL2': {'pos': 13, 'type': 'log'}, 'powerFactorL3': {'pos': 14, 'type': 'log'}, 'voltageL1': {'pos': 15, 'type': 'log'}, 'voltageL2': {'pos': 16, 'type': 'log'}, 'voltageL3': {'pos': 17, 'type': 'log'}, 'currentL1': {'pos': 18, 'type': 'log'}, 'currentL2': {'pos': 19, 'type': 'log'}, 'currentL3': {'pos': 20, 'type': 'log'}, 'power': {'pos': 21, 'type': 'log'}, 'active_power': {'pos': 21, 'type': 'logpos'}, 'reverse_active_power': {'pos': 21, 'type': 'logneg'}, 'apparent_power': {'pos': 22, 'type': 'log'}, 'reactive_power': {'pos': 23, 'type': 'log'}, 'power_factor': {'pos': 24, 'type': 'log'}, 'frequency': {'pos': 25, 'type': 'log'}, 'posiActivePower': {'pos': 26, 'type': 'log'}, 'reverActivePower': {'pos': 27, 'type': 'log'}, 'posiReactivePower': {'pos': 28, 'type': 'log'}, 'reverReactivePower': {'pos': 29, 'type': 'log'}, 'apparentEnergy': {'pos': 30, 'type': 'log'}, 'totalActiveEnergyL1': {'pos': 31, 'type': 'log'}, 'totalActiveEnergyL2': {'pos': 32, 'type': 'log'}, 'totalActiveEnergyL3': {'pos': 33, 'type': 'log'}, 'totalRectiveEnergyL1': {'pos': 34, 'type': 'log'}, 'totalRectiveEnergyL2': {'pos': 35, 'type': 'log'}, 'totalRectiveEnergyL3': {'pos': 36, 'type': 'log'}, 'total_energy': {'pos': 37, 'type': 'log'}, 'l1Voltage2': {'pos': 38, 'type': 'log'}, 'l2Voltage3': {'pos': 39, 'type': 'log'}, 'l3Voltage1': {'pos': 40, 'type': 'log'}, 'pos41': {'pos': 41, 'type': 'log', 'incl': 'no'}, 'pos42': {'pos': 42, 'type': 'log', 'incl': 'no'}, 'pos43': {'pos': 43, 'type': 'log', 'incl': 'no'}, 'pos44': {'pos': 44, 'type': 'log', 'incl': 'no'}, 'pos45': {'pos': 45, 'type': 'log', 'incl': 'no'}, 'pos46': {'pos': 46, 'type': 'log', 'incl': 'no'}, 'pos47': {'pos': 47, 'type': 'log', 'incl': 'no'}, 'pos48': {'pos': 48, 'type': 'log', 'incl': 'no'}, 'pos49': {'pos': 49, 'type': 'log', 'incl': 'no'}, 'pos50': {'pos': 50, 'type': 'log', 'incl': 'no'}, 'pos51': {'pos': 51, 'type': 'log', 'incl': 'no'}, 'pos52': {'pos': 52, 'type': 'log', 'incl': 'no'}, 'pos53': {'pos': 53, 'type': 'log', 'incl': 'no'}, 'pos54': {'pos': 54, 'type': 'log', 'incl': 'no'}, 'pos55': {'pos': 55, 'type': 'log', 'incl': 'no'}, 'pos56': {'pos': 56, 'type': 'log', 'incl': 'no'}, 'pos57': {'pos': 57, 'type': 'log', 'incl': 'no'}, 'pos58': {'pos': 58, 'type': 'log', 'incl': 'no'}, 'pos59': {'pos': 59, 'type': 'log', 'incl': 'no'}, 'pos60': {'pos': 60, 'type': 'log', 'incl': 'no'}, 'pos61': {'pos': 61, 'type': 'log', 'incl': 'no'}, 'pos62': {'pos': 62, 'type': 'log', 'incl': 'no'}, 'pos63': {'pos': 63, 'type': 'log', 'incl': 'no'}, 'pos64': {'pos': 64, 'type': 'log', 'incl': 'no'}, 'pos65': {'pos': 65, 'type': 'log', 'incl': 'no'}, 'pos66': {'pos': 66, 'type': 'log', 'incl': 'no'}} |
2024/03/03 15:02:13 | stdout | T06501b : |
2024/03/03 15:02:13 | stdout | {'decrypt': {'value': 'True'}, 'datalogserial': {'value': 16, 'length': 10, 'type': 'text', 'incl': 'yes'}, 'pvserial': {'value': 76, 'length': 10, 'type': 'text'}, 'date': {'value': 136, 'divide': 10}, 'voltage_l1': {'value': 160, 'length': 4, 'type': 'num', 'divide': 10}, 'voltage_l2': {'value': 168, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'yes'}, 'voltage_l3': {'value': 176, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'yes'}, 'Current_l1': {'value': 184, 'length': 4, 'type': 'num', 'divide': 10}, 'Current_l2': {'value': 192, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'yes'}, 'Current_l3': {'value': 200, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'yes'}, 'act_power_l1': {'value': 208, 'length': 4, 'type': 'numx', 'divide': 10}, 'act_power_l2': {'value': 216, 'length': 4, 'type': 'numx', 'divide': 10, 'incl': 'yes'}, 'act_power_l3': {'value': 224, 'length': 4, 'type': 'numx', 'divide': 10, 'incl': 'yes'}, 'app_power_l1': {'value': 232, 'length': 4, 'type': 'numx', 'divide': 10}, 'app_power_l2': {'value': 240, 'length': 4, 'type': 'numx', 'divide': 10, 'incl': 'yes'}, 'app_power_l3': {'value': 248, 'length': 4, 'type': 'numx', 'divide': 10, 'incl': 'yes'}, 'react_power_l1': {'value': 256, 'length': 4, 'type': 'numx', 'divide': 10}, 'react_power_l2': {'value': 264, 'length': 4, 'type': 'numx', 'divide': 10, 'incl': 'yes'}, 'react_power_l3': {'value': 272, 'length': 4, 'type': 'numx', 'divide': 10, 'incl': 'yes'}, 'powerfactor_l1': {'value': 280, 'length': 4, 'type': 'numx', 'divide': 1000}, 'powerfactor_l2': {'value': 288, 'length': 4, 'type': 'numx', 'divide': 1000, 'incl': 'yes'}, 'powerfactor_l3': {'value': 296, 'length': 4, 'type': 'numx', 'divide': 1000, 'incl': 'yes'}, 'pos_rev_act_power': {'value': 304, 'length': 4, 'type': 'numx', 'divide': 10}, 'pos_act_power': {'value': 304, 'length': 4, 'type': 'numx', 'divide': 10, 'incl': 'yes'}, 'rev_act_power': {'value': 304, 'length': 4, 'type': 'numx', 'divide': 10, 'incl': 'yes'}, 'app_power': {'value': 312, 'length': 4, 'type': 'numx', 'divide': 10}, 'react_power': {'value': 320, 'length': 4, 'type': 'numx', 'divide': 10}, 'powerfactor': {'value': 328, 'length': 4, 'type': 'numx', 'divide': 1000}, 'frequency': {'value': 336, 'length': 4, 'type': 'num', 'divide': 10}, 'L1-2_voltage': {'value': 344, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'yes'}, 'L2-3_voltage': {'value': 352, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'yes'}, 'L3-1_voltage': {'value': 360, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'yes'}, 'pos_act_energy': {'value': 368, 'length': 4, 'type': 'numx', 'divide': 10}, 'rev_act_energy': {'value': 376, 'length': 4, 'type': 'numx', 'divide': 10}, 'pos_act_energy_kvar': {'value': 384, 'length': 4, 'type': 'numx', 'divide': 10, 'incl': 'no'}, 'rev_act_energy_kvar': {'value': 392, 'length': 4, 'type': 'numx', 'divide': 10, 'incl': 'no'}, 'app_energy_kvar': {'value': 400, 'length': 4, 'type': 'numx', 'divide': 10, 'incl': 'no'}, 'act_energy_kwh': {'value': 408, 'length': 4, 'type': 'numx', 'divide': 10, 'incl': 'no'}, 'react_energy_kvar': {'value': 416, 'length': 4, 'type': 'numx', 'divide': 10, 'incl': 'no'}} |
2024/03/03 15:02:13 | stdout | T060120 : |
2024/03/03 15:02:13 | stdout | {'decrypt': {'value': 'True'}, 'datalogserial': {'value': 16, 'length': 10, 'type': 'text', 'incl': 'yes'}, 'pvserial': {'value': 76, 'length': 10, 'type': 'text'}, 'date': {'value': 136, 'divide': 10}, 'recortype1': {'value': 150, 'length': 2, 'type': 'num', 'incl': 'no'}, 'recortype2': {'value': 154, 'length': 2, 'type': 'num', 'incl': 'no'}, 'pvstatus': {'value': 158, 'length': 2, 'type': 'num'}, 'pvpowerin': {'value': 162, 'length': 4, 'type': 'num', 'divide': 10}, 'pv1voltage': {'value': 170, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1current': {'value': 174, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1watt': {'value': 178, 'length': 4, 'type': 'num', 'divide': 10}, 'pv2voltage': {'value': 186, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2current': {'value': 190, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2watt': {'value': 194, 'length': 4, 'type': 'num', 'divide': 10}, 'pv3voltage': {'value': 202, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'pv3current': {'value': 206, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'pv3watt': {'value': 210, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'pvpowerout': {'value': 298, 'length': 4, 'type': 'numx', 'divide': 10}, 'pvfrequentie': {'value': 306, 'length': 2, 'type': 'num', 'divide': 100}, 'pvgridvoltage': {'value': 310, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent': {'value': 314, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower': {'value': 318, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage2': {'value': 326, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent2': {'value': 330, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower2': {'value': 334, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage3': {'value': 342, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent3': {'value': 346, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower3': {'value': 350, 'length': 4, 'type': 'num', 'divide': 10}, 'Vac_RS': {'value': 358, 'length': 2, 'type': 'num', 'divide': 10}, 'Vac_ST': {'value': 362, 'length': 2, 'type': 'num', 'divide': 10}, 'Vac_TR': {'value': 366, 'length': 2, 'type': 'num', 'divide': 10}, 'pvenergytoday': {'value': 370, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytotal': {'value': 378, 'length': 4, 'type': 'num', 'divide': 10}, 'totworktime': {'value': 386, 'length': 4, 'type': 'num', 'divide': 7200}, 'epv1today': {'value': 394, 'length': 4, 'type': 'num', 'divide': 10}, 'epv1total': {'value': 402, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2today': {'value': 410, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2total': {'value': 418, 'length': 4, 'type': 'num', 'divide': 10}, 'epvtotal': {'value': 522, 'length': 4, 'type': 'num', 'divide': 10}, 'pvtemperature': {'value': 530, 'length': 2, 'type': 'num', 'divide': 10}, 'pvipmtemperature': {'value': 534, 'length': 2, 'type': 'num', 'divide': 10}, 'pvboottemperature': {'value': 538, 'length': 2, 'type': 'num', 'divide': 10}, 'temp4': {'value': 542, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'uwBatVolt_DSP': {'value': 546, 'length': 2, 'type': 'num', 'divide': 10}, 'pbusvolt': {'value': 550, 'length': 2, 'type': 'num', 'divide': 1}, 'nbusvolt': {'value': 554, 'length': 2, 'type': 'num', 'divide': 1}} |
2024/03/03 15:02:13 | stdout | T06NNNNXTL3 : |
2024/03/03 15:02:13 | stdout | {'decrypt': {'value': 'True'}, 'datalogserial': {'value': 16, 'length': 10, 'type': 'text', 'incl': 'yes'}, 'pvserial': {'value': 76, 'length': 10, 'type': 'text'}, 'date': {'value': 136, 'divide': 10}, 'recortype1': {'value': 150, 'length': 2, 'type': 'num', 'incl': 'no'}, 'recortype2': {'value': 154, 'length': 2, 'type': 'num', 'incl': 'no'}, 'pvstatus': {'value': 158, 'length': 2, 'type': 'num'}, 'vpv1': {'value': 162, 'length': 2, 'type': 'num', 'divide': 10}, 'vpv2': {'value': 166, 'length': 2, 'type': 'num', 'divide': 10}, 'ppv1': {'value': 170, 'length': 4, 'type': 'num', 'divide': 10}, 'ppv2': {'value': 178, 'length': 4, 'type': 'num', 'divide': 10}, 'buck1curr': {'value': 186, 'length': 2, 'type': 'num', 'divide': 10}, 'buck2curr': {'value': 190, 'length': 2, 'type': 'num', 'divide': 10}, 'op_watt': {'value': 194, 'length': 4, 'type': 'num', 'divide': 10}, 'pvpowerout': {'value': 194, 'length': 4, 'type': 'num', 'divide': 10}, 'op_va': {'value': 204, 'length': 4, 'type': 'num', 'divide': 10}, 'acchr_watt': {'value': 210, 'length': 4, 'type': 'num', 'divide': 10}, 'acchr_VA': {'value': 218, 'length': 4, 'type': 'num', 'divide': 10}, 'bat_Volt': {'value': 226, 'length': 2, 'type': 'num', 'divide': 100}, 'batterySoc': {'value': 230, 'length': 2, 'type': 'num', 'divide': 1}, 'bus_volt': {'value': 234, 'length': 2, 'type': 'num', 'divide': 10}, 'grid_volt': {'value': 238, 'length': 2, 'type': 'num', 'divide': 10}, 'line_freq': {'value': 242, 'length': 2, 'type': 'num', 'divide': 100}, 'outputvolt': {'value': 246, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridvoltage': {'value': 246, 'length': 2, 'type': 'num', 'divide': 10}, 'outputfreq': {'value': 250, 'length': 2, 'type': 'num', 'divide': 100}, 'invtemp': {'value': 258, 'length': 2, 'type': 'num', 'divide': 10}, 'dcdctemp': {'value': 262, 'length': 2, 'type': 'num', 'divide': 10}, 'loadpercent': {'value': 266, 'length': 2, 'type': 'num', 'divide': 10}, 'buck1_ntc': {'value': 286, 'length': 2, 'type': 'num', 'divide': 10}, 'buck2_ntc': {'value': 290, 'length': 2, 'type': 'num', 'divide': 10}, 'OP_Curr': {'value': 294, 'length': 2, 'type': 'num', 'divide': 10}, 'Inv_Curr': {'value': 298, 'length': 2, 'type': 'num', 'divide': 10}, 'AC_InWatt': {'value': 302, 'length': 4, 'type': 'num', 'divide': 10}, 'AC_InVA': {'value': 310, 'length': 4, 'type': 'num', 'divide': 10}, 'faultBit': {'value': 318, 'length': 2, 'type': 'num', 'divide': 1}, 'warningBit': {'value': 322, 'length': 2, 'type': 'num', 'divide': 1}, 'faultValue': {'value': 326, 'length': 2, 'type': 'num', 'divide': 1}, 'warningValue': {'value': 330, 'length': 2, 'type': 'num', 'divide': 1}, 'constantPowerOK': {'value': 346, 'length': 2, 'type': 'num', 'divide': 1}, 'epvtoday': {'value': 358, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytoday': {'value': 358, 'length': 4, 'type': 'num', 'divide': 10}, 'epvtotal': {'value': 366, 'length': 4, 'type': 'num', 'divide': 10}, 'eacCharToday': {'value': 390, 'length': 4, 'type': 'num', 'divide': 10}, 'eacCharTotal': {'value': 398, 'length': 4, 'type': 'num', 'divide': 10}, 'ebatDischarToday': {'value': 406, 'length': 4, 'type': 'num', 'divide': 10}, 'ebatDischarTotal': {'value': 414, 'length': 4, 'type': 'num', 'divide': 10}, 'eacDischarToday': {'value': 422, 'length': 4, 'type': 'num', 'divide': 10}, 'eacDischarTotal': {'value': 430, 'length': 4, 'type': 'num', 'divide': 10}, 'ACCharCurr': {'value': 438, 'length': 2, 'type': 'num', 'divide': 10}, 'ACDischarWatt': {'value': 442, 'length': 4, 'type': 'num', 'divide': 10}, 'ACDischarVA': {'value': 450, 'length': 4, 'type': 'num', 'divide': 10}, 'BatDischarWatt': {'value': 458, 'length': 4, 'type': 'num', 'divide': 10}, 'BatDischarVA': {'value': 466, 'length': 4, 'type': 'num', 'divide': 10}, 'BatWatt': {'value': 474, 'length': 4, 'type': 'numx', 'divide': 10}} |
2024/03/03 15:02:13 | stdout | T06NNNNSPF : |
2024/03/03 15:02:13 | stdout | {'decrypt': {'value': 'True'}, 'datalogserial': {'value': 16, 'length': 10, 'type': 'text', 'divide': 10, 'incl': 'yes'}, 'pvserial': {'value': 36, 'length': 10, 'type': 'text'}, 'date': {'value': 56, 'divide': 10}, 'recortype1': {'value': 70, 'length': 2, 'type': 'num', 'incl': 'no'}, 'recortype2': {'value': 74, 'length': 2, 'type': 'num', 'incl': 'no'}, 'pvstatus': {'value': 78, 'length': 2, 'type': 'num'}, 'vpv1': {'value': 82, 'length': 2, 'type': 'num', 'divide': 10}, 'vpv2': {'value': 86, 'length': 2, 'type': 'num', 'divide': 10}, 'ppv1': {'value': 90, 'length': 4, 'type': 'num', 'divide': 10}, 'ppv2': {'value': 98, 'length': 4, 'type': 'num', 'divide': 10}, 'buck1curr': {'value': 106, 'length': 2, 'type': 'num', 'divide': 10}, 'buck2curr': {'value': 110, 'length': 2, 'type': 'num', 'divide': 10}, 'op_watt': {'value': 114, 'length': 4, 'type': 'num', 'divide': 10}, 'pvpowerout': {'value': 114, 'length': 4, 'type': 'num', 'divide': 10}, 'op_va': {'value': 122, 'length': 4, 'type': 'num', 'divide': 10}, 'acchr_watt': {'value': 130, 'length': 4, 'type': 'num', 'divide': 10}, 'acchr_VA': {'value': 138, 'length': 4, 'type': 'num', 'divide': 10}, 'bat_Volt': {'value': 146, 'length': 2, 'type': 'num', 'divide': 100}, 'batterySoc': {'value': 150, 'length': 2, 'type': 'num', 'divide': 1}, 'bus_volt': {'value': 154, 'length': 2, 'type': 'num', 'divide': 10}, 'grid_volt': {'value': 158, 'length': 2, 'type': 'num', 'divide': 10}, 'line_freq': {'value': 162, 'length': 2, 'type': 'num', 'divide': 100}, 'outputvolt': {'value': 166, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridvoltage': {'value': 166, 'length': 2, 'type': 'num', 'divide': 10}, 'outputfreq': {'value': 170, 'length': 2, 'type': 'num', 'divide': 100}, 'invtemp': {'value': 178, 'length': 2, 'type': 'num', 'divide': 10}, 'dcdctemp': {'value': 182, 'length': 2, 'type': 'num', 'divide': 10}, 'loadpercent': {'value': 186, 'length': 2, 'type': 'num', 'divide': 10}, 'buck1_ntc': {'value': 206, 'length': 2, 'type': 'num', 'divide': 10}, 'buck2_ntc': {'value': 210, 'length': 2, 'type': 'num', 'divide': 10}, 'OP_Curr': {'value': 214, 'length': 2, 'type': 'num', 'divide': 10}, 'Inv_Curr': {'value': 218, 'length': 2, 'type': 'num', 'divide': 10}, 'AC_InWatt': {'value': 222, 'length': 4, 'type': 'num', 'divide': 10}, 'AC_InVA': {'value': 230, 'length': 4, 'type': 'num', 'divide': 10}, 'faultBit': {'value': 238, 'length': 2, 'type': 'num', 'divide': 1}, 'warningBit': {'value': 242, 'length': 2, 'type': 'num', 'divide': 1}, 'faultValue': {'value': 246, 'length': 2, 'type': 'num', 'divide': 1}, 'warningValue': {'value': 250, 'length': 2, 'type': 'num', 'divide': 1}, 'constantPowerOK': {'value': 266, 'length': 2, 'type': 'num', 'divide': 1}, 'epv1tod': {'value': 270, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'epv1tot': {'value': 278, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'epvToday': {'value': 278, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytoday': {'value': 278, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2tod': {'value': 286, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'epvTotal': {'value': 286, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytotal': {'value': 286, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2tot': {'value': 294, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'eacCharToday': {'value': 310, 'length': 4, 'type': 'num', 'divide': 10}, 'eacCharTotal': {'value': 318, 'length': 4, 'type': 'num', 'divide': 10}, 'ebatDischarToday': {'value': 326, 'length': 4, 'type': 'num', 'divide': 10}, 'ebatDischarTotal': {'value': 334, 'length': 4, 'type': 'num', 'divide': 10}, 'eacDischarToday': {'value': 342, 'length': 4, 'type': 'num', 'divide': 10}, 'eacDischarTotal': {'value': 350, 'length': 4, 'type': 'num', 'divide': 10}, 'ACCharCurr': {'value': 358, 'length': 2, 'type': 'num', 'divide': 10}, 'ACDischarWatt': {'value': 362, 'length': 4, 'type': 'num', 'divide': 10}, 'ACDischarVA': {'value': 370, 'length': 4, 'type': 'num', 'divide': 10}, 'BatDischarWatt': {'value': 378, 'length': 4, 'type': 'num', 'divide': 10}, 'BatDischarVA': {'value': 386, 'length': 4, 'type': 'num', 'divide': 10}, 'BatWatt': {'value': 394, 'length': 4, 'type': 'numx', 'divide': 10}} |
2024/03/03 15:02:13 | stdout | T05NNNNSPF : |
2024/03/03 15:02:13 | stdout | {'decrypt': {'value': 'True'}, 'datalogserial': {'value': 16, 'length': 10, 'type': 'text', 'incl': 'yes'}, 'pvserial': {'value': 76, 'length': 10, 'type': 'text'}, 'date': {'value': 136, 'divide': 10}, 'recortype1': {'value': 150, 'length': 2, 'type': 'num', 'incl': 'no'}, 'recortype2': {'value': 154, 'length': 2, 'type': 'num', 'incl': 'no'}, 'pvstatus': {'value': 158, 'length': 2, 'type': 'num'}, 'pvpowerin': {'value': 162, 'length': 4, 'type': 'num', 'divide': 10}, 'pv1voltage': {'value': 170, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1current': {'value': 174, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1watt': {'value': 178, 'length': 4, 'type': 'num', 'divide': 10}, 'pv2voltage': {'value': 186, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2current': {'value': 190, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2watt': {'value': 194, 'length': 4, 'type': 'num', 'divide': 10}, 'pvpowerout': {'value': 298, 'length': 4, 'type': 'numx', 'divide': 10}, 'pvfrequentie': {'value': 306, 'length': 2, 'type': 'num', 'divide': 100}, 'pvgridvoltage': {'value': 310, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent': {'value': 314, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower': {'value': 318, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage2': {'value': 326, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent2': {'value': 330, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower2': {'value': 334, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage3': {'value': 342, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent3': {'value': 346, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower3': {'value': 350, 'length': 4, 'type': 'num', 'divide': 10}, 'totworktime': {'value': 386, 'length': 4, 'type': 'num', 'divide': 7200}, 'eactoday': {'value': 370, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytoday': {'value': 370, 'length': 4, 'type': 'num', 'divide': 10}, 'eactotal': {'value': 378, 'length': 4, 'type': 'num', 'divide': 10}, 'epvtotal': {'value': 522, 'length': 4, 'type': 'num', 'divide': 10}, 'epv1today': {'value': 394, 'length': 4, 'type': 'num', 'divide': 10}, 'epv1total': {'value': 402, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2today': {'value': 410, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2total': {'value': 418, 'length': 4, 'type': 'num', 'divide': 10}, 'pvtemperature': {'value': 530, 'length': 2, 'type': 'num', 'divide': 10}, 'pvipmtemperature': {'value': 534, 'length': 2, 'type': 'num', 'divide': 10}, 'pvboosttemp': {'value': 538, 'length': 2, 'type': 'num', 'divide': 10}, 'bat_dsp': {'value': 546, 'length': 2, 'type': 'num', 'divide': 10}, 'pbusvolt': {'value': 550, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, '#nbusvolt': {'value': 554, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, '#ipf': {'value': 558, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, '#realoppercent': {'value': 562, 'length': 2, 'type': 'num', 'divide': 100, 'incl': 'no'}, '#opfullwatt': {'value': 566, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, '#deratingmode': {'value': 574, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'eacharge_today': {'value': 606, 'length': 4, 'type': 'num', 'divide': 10}, 'eacharge_total': {'value': 614, 'length': 4, 'type': 'num', 'divide': 10}, 'batterytype': {'value': 634, 'length': 2, 'type': 'num', 'divide': 1}, 'uwsysworkmode': {'value': 666, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword0': {'value': 670, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword1': {'value': 674, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword2': {'value': 678, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword3': {'value': 682, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword4': {'value': 686, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword5': {'value': 690, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword6': {'value': 694, 'length': 2, 'type': 'num', 'divide': 1}, 'systemfaultword7': {'value': 698, 'length': 2, 'type': 'num', 'divide': 1}, 'pdischarge1': {'value': 702, 'length': 4, 'type': 'num', 'divide': 10}, 'p1charge1': {'value': 710, 'length': 4, 'type': 'num', 'divide': 10}, 'vbat': {'value': 718, 'length': 2, 'type': 'num', 'divide': 10}, 'SOC': {'value': 722, 'length': 2, 'type': 'num', 'divide': 1}, 'pactouserr': {'value': 726, 'length': 4, 'type': 'num', 'divide': 10}, '#pactousers': {'value': 734, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, '#pactousert': {'value': 742, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'pactousertot': {'value': 750, 'length': 4, 'type': 'num', 'divide': 10}, 'pactogridr': {'value': 758, 'length': 4, 'type': 'num', 'divide': 10}, '#pactogrids': {'value': 766, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, '#pactogridt': {'value': 774, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'pactogridtot': {'value': 782, 'length': 4, 'type': 'num', 'divide': 10}, 'plocaloadr': {'value': 790, 'length': 4, 'type': 'num', 'divide': 10}, '#plocaloads': {'value': 798, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, '#plocaloadt': {'value': 806, 'length': 4, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'plocaloadtot': {'value': 814, 'length': 4, 'type': 'num', 'divide': 10}, '#ipm': {'value': 822, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, '#battemp': {'value': 826, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'spdspstatus': {'value': 830, 'length': 2, 'type': 'num', 'divide': 10}, 'spbusvolt': {'value': 834, 'length': 2, 'type': 'num', 'divide': 10}, 'etouser_tod': {'value': 842, 'length': 4, 'type': 'num', 'divide': 10}, 'etouser_tot': {'value': 850, 'length': 4, 'type': 'num', 'divide': 10}, 'etogrid_tod': {'value': 858, 'length': 4, 'type': 'num', 'divide': 10}, 'etogrid_tot': {'value': 866, 'length': 4, 'type': 'num', 'divide': 10}, 'edischarge1_tod': {'value': 874, 'length': 4, 'type': 'num', 'divide': 10}, 'edischarge1_tot': {'value': 882, 'length': 4, 'type': 'num', 'divide': 10}, 'eharge1_tod': {'value': 890, 'length': 4, 'type': 'num', 'divide': 10}, 'eharge1_tot': {'value': 898, 'length': 4, 'type': 'num', 'divide': 10}, 'elocalload_tod': {'value': 906, 'length': 4, 'type': 'num', 'divide': 10}, 'elocalload_tot': {'value': 914, 'length': 4, 'type': 'num', 'divide': 10}} |
2024/03/03 15:02:13 | stdout | T06NNNNXSPH : |
2024/03/03 15:02:13 | stdout | {'decrypt': {'value': 'True'}, 'datalogserial': {'value': 16, 'length': 10, 'type': 'text', 'incl': 'yes'}, 'pvserial': {'value': 76, 'length': 10, 'type': 'text'}, 'date': {'value': 136, 'divide': 10}, 'recortype1': {'value': 150, 'length': 2, 'type': 'num', 'incl': 'no'}, 'recortype2': {'value': 154, 'length': 2, 'type': 'num', 'incl': 'no'}, 'pvstatus': {'value': 158, 'length': 2, 'type': 'num'}, 'pvpowerin': {'value': 162, 'length': 4, 'type': 'num', 'divide': 10}, 'pv1voltage': {'value': 170, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1current': {'value': 174, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1watt': {'value': 178, 'length': 4, 'type': 'num', 'divide': 10}, 'pv2voltage': {'value': 186, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2current': {'value': 190, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2watt': {'value': 194, 'length': 4, 'type': 'num', 'divide': 10}, 'pvpowerout': {'value': 250, 'length': 4, 'type': 'numx', 'divide': 10}, 'pvfrequentie': {'value': 258, 'length': 2, 'type': 'num', 'divide': 100}, 'pvgridvoltage': {'value': 262, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent': {'value': 266, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower': {'value': 270, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage2': {'value': 278, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent2': {'value': 282, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower2': {'value': 286, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage3': {'value': 294, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent3': {'value': 298, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower3': {'value': 302, 'length': 4, 'type': 'num', 'divide': 10}, 'totworktime': {'value': 346, 'length': 4, 'type': 'num', 'divide': 7200}, 'pvenergytoday': {'value': 354, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytotal': {'value': 362, 'length': 4, 'type': 'num', 'divide': 10}, 'epvtotal': {'value': 370, 'length': 4, 'type': 'num', 'divide': 10}, 'epv1today': {'value': 378, 'length': 4, 'type': 'num', 'divide': 10}, 'epv1total': {'value': 386, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2today': {'value': 394, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2total': {'value': 402, 'length': 4, 'type': 'num', 'divide': 10}, 'pvtemperature': {'value': 530, 'length': 2, 'type': 'num', 'divide': 10}, 'pvipmtemperature': {'value': 546, 'length': 2, 'type': 'num', 'divide': 10}, 'pbusvolt': {'value': 550, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'nbusvolt': {'value': 554, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}} |
2024/03/03 15:02:13 | stdout | T06NNNNX : |
2024/03/03 15:02:13 | stdout | {'decrypt': {'value': 'True'}, 'datalogserial': {'value': 16, 'length': 10, 'type': 'text', 'incl': 'yes'}, 'pvserial': {'value': 36, 'length': 10, 'type': 'text'}, 'date': {'value': 56, 'divide': 10}, 'recortype1': {'value': 70, 'length': 2, 'type': 'num', 'incl': 'no'}, 'recortype2': {'value': 74, 'length': 2, 'type': 'num', 'incl': 'no'}, 'pvstatus': {'value': 78, 'length': 2, 'type': 'num'}, 'pvpowerin': {'value': 82, 'length': 4, 'type': 'num', 'divide': 10}, 'pv1voltage': {'value': 90, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1current': {'value': 94, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1watt': {'value': 98, 'length': 4, 'type': 'num', 'divide': 10}, 'pv2voltage': {'value': 106, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2current': {'value': 110, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2watt': {'value': 114, 'length': 4, 'type': 'num', 'divide': 10}, 'pvpowerout': {'value': 170, 'length': 4, 'type': 'numx', 'divide': 10}, 'pvfrequentie': {'value': 178, 'length': 2, 'type': 'num', 'divide': 100}, 'pvgridvoltage': {'value': 182, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent': {'value': 186, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower': {'value': 190, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage2': {'value': 198, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent2': {'value': 202, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower2': {'value': 206, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage3': {'value': 214, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent3': {'value': 218, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower3': {'value': 222, 'length': 4, 'type': 'num', 'divide': 10}, 'totworktime': {'value': 266, 'length': 4, 'type': 'num', 'divide': 7200}, 'pvenergytoday': {'value': 274, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytotal': {'value': 282, 'length': 4, 'type': 'num', 'divide': 10}, 'epvtotal': {'value': 290, 'length': 4, 'type': 'num', 'divide': 10}, 'epv1today': {'value': 298, 'length': 4, 'type': 'num', 'divide': 10}, 'epv1total': {'value': 306, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2today': {'value': 314, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2total': {'value': 322, 'length': 4, 'type': 'num', 'divide': 10}, 'pvtemperature': {'value': 450, 'length': 2, 'type': 'num', 'divide': 10}, 'pvipmtemperature': {'value': 466, 'length': 2, 'type': 'num', 'divide': 10}, 'pbusvolt': {'value': 470, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'nbusvolt': {'value': 474, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}} |
2024/03/03 15:02:13 | stdout | T05NNNNX : |
2024/03/03 15:02:13 | stdout | {'decrypt': {'value': 'True'}, 'datalogserial': {'value': 16, 'length': 10, 'type': 'text', 'incl': 'yes'}, 'pvserial': {'value': 76, 'length': 10, 'type': 'text'}, 'date': {'value': 136, 'divide': 10}, 'recortype1': {'value': 150, 'length': 2, 'type': 'num', 'incl': 'no'}, 'recortype2': {'value': 154, 'length': 2, 'type': 'num', 'incl': 'no'}, 'pvstatus': {'value': 158, 'length': 2, 'type': 'num'}, 'pvpowerin': {'value': 162, 'length': 4, 'type': 'num', 'divide': 10}, 'pv1voltage': {'value': 170, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1current': {'value': 174, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1watt': {'value': 178, 'length': 4, 'type': 'num', 'divide': 10}, 'pv2voltage': {'value': 186, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2current': {'value': 190, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2watt': {'value': 194, 'length': 4, 'type': 'num', 'divide': 10}, 'pvpowerout': {'value': 202, 'length': 4, 'type': 'numx', 'divide': 10}, 'pvfrequentie': {'value': 210, 'length': 2, 'type': 'num', 'divide': 100}, 'pvgridvoltage': {'value': 214, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent': {'value': 218, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower': {'value': 222, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage2': {'value': 230, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent2': {'value': 234, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower2': {'value': 238, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage3': {'value': 246, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent3': {'value': 250, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower3': {'value': 254, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytoday': {'value': 262, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytotal': {'value': 270, 'length': 4, 'type': 'num', 'divide': 10}, 'totworktime': {'value': 278, 'length': 4, 'type': 'num', 'divide': 7200}, 'pvtemperature': {'value': 286, 'length': 2, 'type': 'num', 'divide': 10}, 'isof': {'value': 290, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'gfcif': {'value': 294, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'dcif': {'value': 298, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'vpvfault': {'value': 302, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'vacfault': {'value': 306, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'facfault': {'value': 310, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'tmpfault': {'value': 314, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'faultcode': {'value': 318, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'pvipmtemperature': {'value': 322, 'length': 2, 'type': 'num', 'divide': 10}, 'pbusvolt': {'value': 326, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'nbusvolt': {'value': 330, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'epv1today': {'value': 358, 'length': 4, 'type': 'num', 'divide': 10}, 'epv1total': {'value': 366, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2today': {'value': 374, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2total': {'value': 382, 'length': 4, 'type': 'num', 'divide': 10}, 'epvtotal': {'value': 390, 'length': 4, 'type': 'num', 'divide': 10}} |
2024/03/03 15:02:13 | stdout | T06NNNN : |
2024/03/03 15:02:13 | stdout | {'decrypt': {'value': 'True'}, 'datalogserial': {'value': 16, 'length': 10, 'type': 'text', 'incl': 'yes'}, 'pvserial': {'value': 36, 'length': 10, 'type': 'text'}, 'date': {'value': 56, 'divide': 10}, 'recortype1': {'value': 70, 'length': 2, 'type': 'num', 'incl': 'no'}, 'recortype2': {'value': 74, 'length': 2, 'type': 'num', 'incl': 'no'}, 'pvstatus': {'value': 78, 'length': 2, 'type': 'num'}, 'pvpowerin': {'value': 82, 'length': 4, 'type': 'num', 'divide': 10}, 'pv1voltage': {'value': 90, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1current': {'value': 94, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1watt': {'value': 98, 'length': 4, 'type': 'num', 'divide': 10}, 'pv2voltage': {'value': 106, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2current': {'value': 110, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2watt': {'value': 114, 'length': 4, 'type': 'num', 'divide': 10}, 'pvpowerout': {'value': 122, 'length': 4, 'type': 'numx', 'divide': 10}, 'pvfrequentie': {'value': 130, 'length': 2, 'type': 'num', 'divide': 100}, 'pvgridvoltage': {'value': 134, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent': {'value': 138, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower': {'value': 142, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage2': {'value': 150, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent2': {'value': 154, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower2': {'value': 158, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage3': {'value': 166, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent3': {'value': 170, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower3': {'value': 174, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytoday': {'value': 182, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytotal': {'value': 190, 'length': 4, 'type': 'num', 'divide': 10}, 'totworktime': {'value': 198, 'length': 4, 'type': 'num', 'divide': 7200}, 'pvtemperature': {'value': 206, 'length': 2, 'type': 'num', 'divide': 10}, 'isof': {'value': 210, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'gfcif': {'value': 214, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'dcif': {'value': 218, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'vpvfault': {'value': 222, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'vacfault': {'value': 226, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'facfault': {'value': 230, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'tmpfault': {'value': 234, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'faultcode': {'value': 238, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'pvipmtemperature': {'value': 242, 'length': 2, 'type': 'num', 'divide': 10}, 'pbusvolt': {'value': 246, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'nbusvolt': {'value': 250, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'epv1today': {'value': 278, 'length': 4, 'type': 'num', 'divide': 10}, 'epv1total': {'value': 286, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2today': {'value': 294, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2total': {'value': 302, 'length': 4, 'type': 'num', 'divide': 10}, 'epvtotal': {'value': 310, 'length': 4, 'type': 'num', 'divide': 10}, 'rac': {'value': 318, 'length': 4, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'eractoday': {'value': 326, 'length': 4, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'eractotal': {'value': 334, 'length': 4, 'type': 'num', 'divide': 1, 'incl': 'no'}} |
2024/03/03 15:02:13 | stdout | T05NNNN : |
2024/03/03 15:02:13 | stdout | {'decrypt': {'value': 'False'}, 'datalogserial': {'value': 16, 'length': 10, 'type': 'text', 'incl': 'yes'}, 'pvserial': {'value': 36, 'length': 10, 'type': 'text'}, 'date': {'value': 56, 'divide': 10}, 'recortype1': {'value': 70, 'length': 2, 'type': 'num', 'incl': 'no'}, 'recortype2': {'value': 74, 'length': 2, 'type': 'num', 'incl': 'no'}, 'pvstatus': {'value': 78, 'length': 2, 'type': 'num'}, 'pvpowerin': {'value': 82, 'length': 4, 'type': 'num', 'divide': 10}, 'pv1voltage': {'value': 90, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1current': {'value': 94, 'length': 2, 'type': 'num', 'divide': 10}, 'pv1watt': {'value': 98, 'length': 4, 'type': 'num', 'divide': 10}, 'pv2voltage': {'value': 106, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2current': {'value': 110, 'length': 2, 'type': 'num', 'divide': 10}, 'pv2watt': {'value': 114, 'length': 4, 'type': 'num', 'divide': 10}, 'pvpowerout': {'value': 122, 'length': 4, 'type': 'num', 'divide': 10}, 'pvfrequentie': {'value': 130, 'length': 2, 'type': 'num', 'divide': 100}, 'pvgridvoltage': {'value': 134, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent': {'value': 138, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower': {'value': 142, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage2': {'value': 150, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent2': {'value': 154, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower2': {'value': 158, 'length': 4, 'type': 'num', 'divide': 10}, 'pvgridvoltage3': {'value': 166, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridcurrent3': {'value': 170, 'length': 2, 'type': 'num', 'divide': 10}, 'pvgridpower3': {'value': 174, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytoday': {'value': 182, 'length': 4, 'type': 'num', 'divide': 10}, 'pvenergytotal': {'value': 190, 'length': 4, 'type': 'num', 'divide': 10}, 'totworktime': {'value': 198, 'length': 4, 'type': 'num', 'divide': 7200}, 'pvtemperature': {'value': 206, 'length': 2, 'type': 'num', 'divide': 10}, 'isof': {'value': 210, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'gfcif': {'value': 214, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'dcif': {'value': 218, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'vpvfault': {'value': 222, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'vacfault': {'value': 226, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'facfault': {'value': 230, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'tmpfault': {'value': 234, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'faultcode': {'value': 238, 'length': 2, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'pvipmtemperature': {'value': 242, 'length': 2, 'type': 'num', 'divide': 10}, 'pbusvolt': {'value': 246, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'nbusvolt': {'value': 250, 'length': 2, 'type': 'num', 'divide': 10, 'incl': 'no'}, 'epv1today': {'value': 278, 'length': 4, 'type': 'num', 'divide': 10}, 'epv1total': {'value': 286, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2today': {'value': 294, 'length': 4, 'type': 'num', 'divide': 10}, 'epv2total': {'value': 302, 'length': 4, 'type': 'num', 'divide': 10}, 'epvtotal': {'value': 310, 'length': 4, 'type': 'num', 'divide': 10}, 'rac': {'value': 318, 'length': 4, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'eractoday': {'value': 326, 'length': 4, 'type': 'num', 'divide': 1, 'incl': 'no'}, 'eractotal': {'value': 334, 'length': 4, 'type': 'num', 'divide': 1, 'incl': 'no'}} |
2024/03/03 15:02:13 | stdout | T02NNNN : |
2024/03/03 15:02:13 | stdout | Grott layout records loaded |
2024/03/03 15:02:13 | stdout | |
2024/03/03 15:02:13 | stdout | Grott process json layout files |
2024/03/03 15:02:13 | stdout | |
2024/03/03 15:02:13 | stdout | Grott override settings if set in commandline |
2024/03/03 15:02:13 | stdout | |
2024/03/03 15:02:13 | stdout | Grott process environmental variables |
2024/03/03 15:02:13 | stdout | |
2024/03/03 15:02:13 | stdout | Grott process configuration file |
2024/03/03 15:02:13 | stdout | |
2024/03/03 15:02:13 | stdout | noipf: False |
2024/03/03 15:02:13 | stdout | blockcmd: False |
2024/03/03 15:02:13 | stdout | pvoutput: False |
2024/03/03 15:02:13 | stdout | inverterid: automatic |
2024/03/03 15:02:13 | stdout | nomqtt: False |
2024/03/03 15:02:13 | stdout | output file: <_io.TextIOWrapper name=' |
2024/03/03 15:02:13 | stdout | config file: grott.ini |
2024/03/03 15:02:13 | stdout | verbose: True |
2024/03/03 15:02:13 | stdout | Grott Command line parameters processed: |
2024/03/03 15:02:13 | stdout | |
2024/03/03 15:02:13 | stdout | Grott Growatt logging monitor : 2.8.3 |
Somehow your the configuration is not ok. I expected invtype: default to be: invtype: sph.
Are you using docker or "stand-alone" Grott. Howw did you specified the invtype parameter?
I'm running everything using docker (container manager, running on a Synology NAS). My grott.ini file has the following lines for specifying inverter type:
# Specify inverter id (not necessary in version >2.1.0 if compat = false!)
#inverterid = OUCTCJM022
# Specify the type of the inverter (default/sph/spf/max)
invtype = sph
It does seem like the ini file is somehow not being read correctly or ignored. Not sure what to try next
@johanmeijer I've just deleted and rebuilt the containers and everything is now working as expected! Not sure what changed, but it is reading the config file correctly now and mapping to SPH. Thank you!
Hello,
Trying to get this working but am getting odd mappings of the data from the inverter.
I have invtype set to sph in the config but there is no sign of an sph layout being used when looking at the logs as posted below.
What should I be doing/changing to get this to work please? (if any more info or logs are needed please let me know).
Log below:
2024/02/22 15:54:26 | stdout | - Data less then minimum record length, data not processed -- | -- | -- 2024/02/22 15:54:26 | stdout |