john30 / ebusd-configuration

ebusd configuration files
GNU General Public License v3.0
178 stars 280 forks source link

hcmode.inc Status #43

Open memtew opened 7 years ago

memtew commented 7 years ago

In hcmode.inc we have Status command:

r,,Status,Status,,,B511,03,,,temp;press;press;HEX:4,,,

If I try to check status:

root@core:/etc/ebusd/vaillant# ebusctl r -c hc Status
ERR: element not found

But my VR630 sending hc status like other circuits (hwc for example), PBSB B504 with ID 0D:

1026b504010d / 0532000d031a = 632

If I comment line with PBSB B511 and add Status command from hwcmode.inc it's works fine:

r,,Status,Status,,,,0D,,,temp0;onoff;temp;temp0,,,
root@core:/etc/ebusd/vaillant# ebusctl r -c hc Status
50;off;45.94;26

Info (maybe needed):

version: ebusd 2.4.p20170112
signal: acquired
symbol rate: 77
reconnects: 0
masters: 3
messages: 903
conditional: 12
poll: 0
update: 8
address 03: master #11
address 08: slave #11, scanned "MF=Vaillant;ID=BAI00;SW=0703;HW=7401", loaded "bai.0010007508.inc" ([PROD='0010007522']), "vaillant/08.bai.csv"
address 10: master #2
address 15: slave #2, scanned "MF=Vaillant;ID=UI   ;SW=0506;HW=6201", loaded "vaillant/15.ui.csv"
address 23: slave, scanned "MF=Vaillant;ID=VR630;SW=0500;HW=6301", loaded "vaillant/23.vr630.cc.csv"
address 25: slave, scanned "MF=Vaillant;ID=VR630;SW=0500;HW=6301", loaded "vaillant/25.vr630.hwc.csv"
address 26: slave, scanned "MF=Vaillant;ID=VR630;SW=0500;HW=6301", loaded "vaillant/26.vr630.hc.csv"
address 31: master #8, ebusd
address 36: slave #8, ebusd
address 50: slave, scanned "MF=Vaillant;ID=VR630;SW=0500;HW=6301", loaded "vaillant/50.vr630.mc.csv"
address 51: slave, scanned "MF=Vaillant;ID=VR630;SW=0500;HW=6301", loaded "vaillant/51.vr630.mc.3.csv"
address 52: slave, scanned "MF=Vaillant;ID=MC2  ;SW=0500;HW=6301", loaded "vaillant/52.mc2.mc.4.csv"
address 53: slave, scanned "MF=Vaillant;ID=MC2  ;SW=0500;HW=6301", loaded "vaillant/53.mc2.mc.5.csv"
memtew commented 7 years ago

Also, the same problem with Mode command on hc circuit.