Open pascalwinters opened 1 day ago
You need to change filter name to include Flow:
filter-name = Flow|...
and also directions to show writable values:
filter-direction = r|u|^w
You need to change filter name to include Flow:
filter-name = Flow|...
This doesn't help and the filter-direction was already configured on that way. So the entity is not added to HA
And also temp
was already added to the filer-name, so it should be already added. Also because sensor.ebusd_basv_hc1actualflowtempdesired_value
is already added.
@pascalwinters
Changing the message type from 'w' to 'uw' (update-write) works for me (all filters disabled in mqtt-hassio.cfg):
*r,,,,,,B523,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
*uw,,,,,,B523,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
uw,,Mc1FlowTempDesired,,,,,0200,FTStatus,,onoff,,,,FTDesired,,temp1,,,,MixerStatus,s,onoff,,,,MixerMovement,s,percents,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
uw,,Mc2FlowTempDesired,,,,,0201,FTStatus,,onoff,,,,FTDesired,,temp1,,,,MixerStatus,s,onoff,,,,MixerMovement,s,percents,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
uw,,Mc3FlowTempDesired,,,,,0202,FTStatus,,onoff,,,,FTDesired,,temp1,,,,MixerStatus,s,onoff,,,,MixerMovement,s,percents,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
@pascalwinters
Changing the message type from 'w' to 'uw' (update-write) works for me (all filters disabled in mqtt-hassio.cfg):
*r,,,,,,B523,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, *uw,,,,,,B523,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, uw,,Mc1FlowTempDesired,,,,,0200,FTStatus,,onoff,,,,FTDesired,,temp1,,,,MixerStatus,s,onoff,,,,MixerMovement,s,percents,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, uw,,Mc2FlowTempDesired,,,,,0201,FTStatus,,onoff,,,,FTDesired,,temp1,,,,MixerStatus,s,onoff,,,,MixerMovement,s,percents,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, uw,,Mc3FlowTempDesired,,,,,0202,FTStatus,,onoff,,,,FTDesired,,temp1,,,,MixerStatus,s,onoff,,,,MixerMovement,s,percents,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
What do you mean with uw
?
At the moment I have configured it like this: filter-direction = r|u|^w
@chrizzzp points to modify 26.vr_71.csv, because it show that sensors are only for write not for read.
What do you mean with
uw
? At the moment I have configured it like this:filter-direction = r|u|^w
Message type is defined in the CSV. I use local CSVs and edited 26.vr_71.csv
.
Should we use those files: https://github.com/john30/ebusd-configuration/tree/master/src
for the latest version?
How do I get those sensors in HA with the mqtt-hassio.cfg file?
And especially the McxFlowTempDesired values because the both SensorData sensors are there.
https://github.com/john30/ebusd-configuration/blob/master/ebusd-2.1.x/en/vaillant/26.vr_71.csv