unable to load scan config 15 #26

Closed Benni1123 closed 9 months ago

Benni1123 commented 9 months ago

Hi! Ich habe jetzt meinen neuen eBUS Adapter angeschlossen. Ich habe das Home Assistant Addon getestet und und in einer Debian VM.

Ich erhalte diesen Fehler: 2023-10-05 21:00:28.073 [update notice] received unknown MS cmd: 1008b5110102 / 06033c96468278 2023-10-05 21:00:35.648 [bus notice] scan 08: ;Vaillant;BAI00;0807;7603 2023-10-05 21:00:35.648 [update notice] store 08 ident: done 2023-10-05 21:00:35.648 [update notice] sent scan-read scan.08 QQ=31: Vaillant;BAI00;0807;7603 2023-10-05 21:00:35.648 [bus notice] scan 08: ;Vaillant;BAI00;0807;7603 2023-10-05 21:00:36.164 [main notice] read common config file vaillant/broadcast.csv 2023-10-05 21:00:36.288 [main notice] read common config file vaillant/scan.csv 2023-10-05 21:00:36.412 [main notice] read common config file vaillant/general.csv 2023-10-05 21:00:36.536 [main notice] read scan config file vaillant/08.bai.csv for ID "bai00", SW0807, HW7603 2023-10-05 21:00:36.783 [update notice] sent scan-read scan.08 id QQ=31: 2023-10-05 21:00:37.065 [update notice] sent scan-read scan.08 id QQ=31: 2023-10-05 21:00:37.397 [bus error] send to 08: ERR: read timeout, retry 2023-10-05 21:00:38.272 [bus error] send to 08: ERR: SYN received, retry 2023-10-05 21:00:38.346 [bus error] device status: eBUS comm error: overrun 2023-10-05 21:00:38.353 [bus error] arbitration start error 2023-10-05 21:00:38.368 [update notice] received unknown MS cmd: 1008b5100900002dffffff040000 / 0101 2023-10-05 21:00:38.392 [bus error] send to 08: ERR: SYN received 2023-10-05 21:00:38.392 [bus error] send message part 2: ERR: SYN received 2023-10-05 21:00:38.392 [main error] error reading message scan.08 id: ERR: SYN received 2023-10-05 21:00:38.614 [update notice] sent scan-read scan.08 id QQ=31: 2023-10-05 21:00:38.886 [update notice] sent scan-read scan.08 id QQ=31: 2023-10-05 21:00:39.172 [update notice] sent scan-read scan.08 id QQ=31: 2023-10-05 21:00:39.342 [bus error] device status: eBUS comm error: overrun 2023-10-05 21:00:39.444 [update notice] sent scan-read scan.08 id QQ=31: 21;22;44;0010022010;0001;017235;N0 2023-10-05 21:00:39.818 [main notice] found messages: 224 (3 conditional on 28 conditions, 0 poll, 10 update) 2023-10-05 21:00:40.117 [update notice] sent scan-read scan.08 id QQ=31: 21;22;44;0010022010;0001;017235;N0 2023-10-05 21:00:40.403 [update notice] sent scan-read scan.08 id QQ=31: 21;22;44;0010022010;0001;017235;N0 2023-10-05 21:00:40.676 [update notice] sent scan-read scan.08 id QQ=31: 21;22;44;0010022010;0001;017235;N0 2023-10-05 21:00:42.065 [update notice] sent poll-read bai CounterStartattempts1 QQ=31: 0 2023-10-05 21:00:43.050 [bus notice] scan 15: ;Vaillant;CTLV3;0612;3004 2023-10-05 21:00:43.050 [update notice] store 15 ident: done 2023-10-05 21:00:43.050 [update notice] sent scan-read scan.15 QQ=31: Vaillant;CTLV3;0612;3004 2023-10-05 21:00:43.050 [bus notice] scan 15: ;Vaillant;CTLV3;0612;3004 2023-10-05 21:00:43.345 [update notice] sent unknown MS cmd: 3115b5090124 / 09003231323233323030 2023-10-05 21:00:43.602 [update notice] sent scan-read scan.15 id QQ=31: 2023-10-05 21:00:43.881 [update notice] sent scan-read scan.15 id QQ=31: 2023-10-05 21:00:44.153 [update notice] sent scan-read scan.15 id QQ=31: 21;22;32;0010045485;0953;011543;N1 2023-10-05 21:00:44.153 [bus notice] scan 15: ;21;22;32;0010045485;0953;011543;N1 2023-10-05 21:00:44.277 [main error] unable to load scan config 15: no file from vaillant with prefix 15 matches ID "ctlv3", SW0612, HW3004 2023-10-05 21:00:44.277 [main error] scan config 15: ERR: element not found 2023-10-05 21:00:47.285 [update notice] sent poll-read bai CounterStartattempts2 QQ=31: 0 2023-10-05 21:00:47.581 [update notice] received poll-read bai Status01 QQ=10: 25.0;25.0;-;29.0;-;off 2023-10-05 21:00:47.861 [update notice] received update-write bai SetMode QQ=10: auto;22.5;-;-;0;0;1;0;0;0 2023-10-05 21:00:53.499 [bus error] poll bai CounterStartAttempts3 failed: ERR: SYN received 2023-10-05 21:00:53.914 [bus notice] arbitration won in invalid state ready

Ich sehe einige Temperaturen, aber ich kann nichts einstellen/ändern.

Wo und wie kann ich die richtige Config File einstellen?

Ich habe die Vaillant ecoTEC plus VC/VCW/VCI 1 mit dem VRT380.

scan id = no data stored scan.08 = Vaillant;BAI00;0807;7603 scan.08 id = 21;22;44;0010022010;0001;017235;N0 scan.15 = Vaillant;CTLV3;0612;3004 scan.15 id = 21;22;32;0010045485;0953;011543;N1

john30 commented 9 months ago

this is not an adapter issue but just a missing configuration file for this particular heater.

look in ebusd-configuration instead